Literature DB >> 2923153

Accuracy of topographic measurements with the Optic Nerve Head Analyzer.

M B Shields1, J S Tiedeman, K N Miller, D Hickingbotham, A R Ollie.   

Abstract

We used a plastic model of the human eye to study the accuracy with which the Optic Nerve Head Analyzer estimates the surface contour and two-dimensional size of the optic nerve head. Computer-generated contour lines were similar to the actual cross-sectional contour of plastic cups as photographed by scanning electron microscopy. The magnification error of computer-measured cup diameters was inversely related to the axial length of the model. The slope of this relationship was reduced with the use of either refraction or axial length as a correction factor for magnification error. Of the two correction factors, the former provided the closest estimation of the known diameters in the phakic model, while the latter performed better in the aphakic model.

Entities:  

Mesh:

Year:  1989        PMID: 2923153     DOI: 10.1016/0002-9394(89)90312-7

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  6 in total

1.  Intraocular pressure-related pattern of optic disc cupping in adult glaucoma patients.

Authors:  D H Shin; M K Lee; K S Briggs; C Kim; J H Zeiter; B McCarty
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1992       Impact factor: 3.117

2.  Early detection of glaucoma by longitudinal monitoring of the optic disc structure.

Authors:  J Funk
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1991       Impact factor: 3.117

3.  Enhanced detection of normal retinal nerve-fiber striations using a charge-coupled device and digital filtering.

Authors:  D W Richards; J R Janesick; S T Elliot; A Dingizian; R Velthuizen; Q Wei; L P Clarke
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1993-10       Impact factor: 3.117

4.  Optic nerve head analyzer and Heidelberg retina tomograph: relative error and reproducibility of topographic measurements in a model eye with simulated cataract.

Authors:  P Janknecht; J Funk
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1995-08       Impact factor: 3.117

5.  Optic nerve head analyser and Heidelberg retina tomograph: accuracy and reproducibility of topographic measurements in a model eye and in volunteers.

Authors:  P Janknecht; J Funk
Journal:  Br J Ophthalmol       Date:  1994-10       Impact factor: 4.638

6.  Optic disc excavation in the atrophic stage of Leber's hereditary optic neuropathy: comparison with normal tension glaucoma.

Authors:  Yukihiko Mashima; Itaru Kimura; Yusuke Yamamoto; Hisao Ohde; Yuichirou Ohtake; Tomihiko Tanino; Goji Tomita; Yoshihisa Oguchi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-01-25       Impact factor: 3.117

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.