[Comparison of two laser scanning tomography systems for three-dimensional analysis of the optic papilla].

K Rohrschneider1, R O Burk, H E Völcker.   

Abstract

The Heidelberg retina tomograph (HRT) allows three-dimensional topographic analysis of the optic disc based on the same confocal laser tomographic scanning principle as the laser tomographic scanner (LTS). We evaluated the reproducibility attained with the HRT and compared the data acquired with the two instruments. To determine the reproducibility of the data acquisition with the HRT, we measured 27 glaucomatous discs five times each. The mean standard deviation was 0.075 mm2 for the cup area, 0.035 mm3 for the cup volume and 0.018 mm for the mean cup depth. In addition, 50 eyes were examined with both instruments. Measurements of the optic disc area and cup area demonstrated slightly increased values obtained with the HRT (mean difference 4.1% and 6.6%, respectively), while the values for cup volume and cup depth were 15.5% and 13.9% larger than those obtained with the LTS. The comparison between LTS and HRT demonstrates good agreement of the reproducibility concerning three-dimensional topometric data relating to the optic nerve head. The differences between the measurements may be due to a modified optical pathway enabling direct assessment of the intraocular focus position in the HRT. In conclusion, the improved and simplified method of laser scanning tomography as used in the HRT yields reproducible and reliable measurements of the optic nerve head. In addition, this instrument makes it possible to obtain high-quality images without pupil dilatation with a significantly shorter examination time.

Entities:  

Mesh:

Year:  1993        PMID: 8124023

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  4 in total

1.  Topographic characteristics of the optic nerve head measured with scanning laser tomography in normal Japanese subjects.

Authors:  Hideya Uchida; Tetsuya Yamamoto; Makoto Araie; Goji Tomita; Motohiro Shirakashi; Keiji Yoshikawa
Journal:  Jpn J Ophthalmol       Date:  2005 Nov-Dec       Impact factor: 2.447

2.  [Measurement of the disc area by indirect ophthalmoscopy].

Authors:  M Haustein; E Schmidt; E Spörl; L E Pillunat; A G Böhm
Journal:  Ophthalmologe       Date:  2009-02       Impact factor: 1.059

3.  Optic nerve head analyser and Heidelberg retina tomograph: accuracy and reproducibility of topographic measurements in a model eye and in volunteers.

Authors:  P Janknecht; J Funk
Journal:  Br J Ophthalmol       Date:  1994-10       Impact factor: 4.638

4.  [Reproducibility of measurements of the peripapillary retinal nerve fibre layer thickness. Optical coherence tomography versus retinal thickness analyzer].

Authors:  R Krist; E M Hoffmann; O Schwenn
Journal:  Ophthalmologe       Date:  2005-12       Impact factor: 1.059

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.