Literature DB >> 8489444

Effect of repetitive imaging on topographic measurements of the optic nerve head.

R N Weinreb1, M Lusky, D U Bartsch, D Morsman.   

Abstract

OBJECTIVE: A confocal scanning diode laser ophthalmoscope was used to determine the number of examinations needed to obtain highly reproducible topographic measurements of the optic nerve head and peripapillary retina.
DESIGN: Topographic images of the optic nerve head and peripapillary retina were obtained in one randomly selected eye on five separate visits. On each occasion the selected eye had five examinations. For each examination, one image was acquired (a total of 25 images per eye). Reproducibility was calculated as the average SD of all image elements (65,536 pixels).
SETTING: Glaucoma referral center.
SUBJECTS: Five normal subjects and five patients with glaucoma. INTERVENTION: Topographic imaging of the optic nerve head and peripapillary retina. MAIN OUTCOME MEASURE: Number of examinations needed to obtain highly reproducible topographic measurements.
RESULTS: In healthy subjects, reproducibility with one examination per visit was 35.5 microns; this improved to 25.7 microns with three examinations and 22.5 microns with five examinations. In older patients with glaucoma, the reproducibility improved from 40.2 microns with one examination per visit to 28.5 and 24.1 microns with three and five examinations, respectively.
CONCLUSION: We recommend a series of three examinations to provide high reproducibility with optimal efficiency in terms of time and materials used.

Entities:  

Mesh:

Year:  1993        PMID: 8489444     DOI: 10.1001/archopht.1993.01090050070031

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  32 in total

1.  Comparison between laser scanning tomography and computerised image analysis of the optic disc.

Authors:  A Azuara-Blanco; G L Spaeth; J Nicholl; I M Lanzl; J J Augsburger
Journal:  Br J Ophthalmol       Date:  1999-03       Impact factor: 4.638

2.  The Humphrey optical coherence tomography scanner: quantitative analysis and reproducibility study of the normal human retinal nerve fibre layer.

Authors:  A L Jones; N J Sheen; R V North; J E Morgan
Journal:  Br J Ophthalmol       Date:  2001-06       Impact factor: 4.638

3.  Reliability in the use of the Heidelberg retina tomograph.

Authors:  G Meerhoff; W Meerhoff
Journal:  Int Ophthalmol       Date:  2001       Impact factor: 2.031

Review 4.  Imaging in glaucoma.

Authors:  Daniel M Stein; Gadi Wollstein; Joel S Schuman
Journal:  Ophthalmol Clin North Am       Date:  2004-03

5.  Morphological changes in the optic disc after vitrectomy and fluid-air exchange.

Authors:  Hirokazu Ohashi; Yuzo Kasuga; Naruhiko Hata; Shin-Ichi Manabe; Yasuyuki Takashima; Seiki Lee; Ryoji Yamakawa
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2004-02-13       Impact factor: 3.117

6.  En face optical coherence tomography: a new method to analyse structural changes of the optic nerve head in rat glaucoma.

Authors:  L Guo; V Tsatourian; V Luong; A G Podoleanu; A G Podolean; D A Jackson; F W Fitzke; M F Cordeiro
Journal:  Br J Ophthalmol       Date:  2005-09       Impact factor: 4.638

7.  Improved visualisation of choroidal neovascularisation by scanning laser ophthalmoscope using image averaging.

Authors:  D U Bartsch; M H El-Bradey; A El-Musharaf; W R Freeman
Journal:  Br J Ophthalmol       Date:  2005-08       Impact factor: 4.638

8.  Effects of short term increase of intraocular pressure on optic disc cupping.

Authors:  A Azuara-Blanco; A Harris; L B Cantor; M M Abreu; M Weinland
Journal:  Br J Ophthalmol       Date:  1998-08       Impact factor: 4.638

9.  The rate of structural change: the confocal scanning laser ophthalmoscopy ancillary study to the ocular hypertension treatment study.

Authors:  Linda M Zangwill; Sonia Jain; Keri Dirkes; Feng He; Felipe A Medeiros; Gary L Trick; James D Brandt; George A Cioffi; Anne L Coleman; Jeffrey M Liebmann; Jody R Piltz-Seymour; Mae O Gordon; Michael A Kass; Robert N Weinreb
Journal:  Am J Ophthalmol       Date:  2013-03-14       Impact factor: 5.258

10.  Reproducibility of volumetric measurements of normal maculae with the Heidelberg retina tomograph.

Authors:  H J Zambarakji; J E Evans; W M Amoaku; S A Vernon
Journal:  Br J Ophthalmol       Date:  1998-08       Impact factor: 4.638

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.