Literature DB >> 9828771

Reproducibility of volumetric measurements of normal maculae with the Heidelberg retina tomograph.

H J Zambarakji1, J E Evans, W M Amoaku, S A Vernon.   

Abstract

AIMS: The Heidelberg retina tomograph (HRT) is a scanning laser ophthalmoscope with confocal optics. The reproducibility of the optic nerve head topography is accurate and reliable. The authors describe a new technique for the assessment of macular thickening by volumetric quantification and present the results of its reproducibility in normal subjects.
METHODS: Topographic images of the macula, centred on the fovea were obtained in one eye of 44 normal subjects. The volumes above the reference plane bound by a 1 mm, 2 mm, and 3 mm diameter circle were measured. The reference plane was adjusted to the lowest point of the height variation of the contour line at each examination. The reproducibility of repeated measurements within a 2 mm diameter circle was assessed in 20 eyes selected at random. Three HRT scans of each eye were obtained. The measurements of volume above reference plane of each scan were repeated three times on three separate days.
RESULTS: The intrascan coefficients of variability measured 7.12-9.57%. The 95% confidence interval for the geometric mean ratio of single volume measurements was 0.92 to 1.24 for scans 1 and 2, 0.89 to 1.17 for scans 1 and 3, and 0.81 to 1.12 for scans 2 and 3. When the mean of three measurements of one scan were compared with the mean of three measurements of a second scan, the 95% confidence interval for their geometric mean ratio was 0.89 to 1.20 for scans 1 and 2, 0.89 to 1.16 for scans 1 and 3, and 0.84 to 1.13 for scans 2 and 3. The average standard deviation (SD) for one measurement per scan was 0.02 mm3, and 0.019 mm3 for two or three measurements per scan. Linear regression demonstrated a significant increase in SD as volumetric measurements increased (p = 0.003). Age did not significantly affect the SD of volumetric measurements (p = 0.797). The authors found no significant differences in volumetric measurements across all ages for all three circles (p = 0.314, p = 0.471, p = 0.267).
CONCLUSION: Good reproducibility for volumetric measurements at the macula was found with the HRT using the above technique in normal subjects. This method may be extremely useful for the identification and quantification of diabetic macular oedema and for monitoring the effects of argon laser photocoagulation.

Entities:  

Mesh:

Year:  1998        PMID: 9828771      PMCID: PMC1722722          DOI: 10.1136/bjo.82.8.884

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  19 in total

1.  Topography of the retinal thickness in normal subjects.

Authors:  M Shahidi; R C Zeimer; M Mori
Journal:  Ophthalmology       Date:  1990-09       Impact factor: 12.079

2.  Detection and quantification of hyperfluorescent leakage by computer analysis of fundus fluorescein angiograms.

Authors:  R P Phillips; P G Ross; M Tyska; P F Sharp; J V Forrester
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1991       Impact factor: 3.117

3.  Reproducibility of topographic measurements of the optic nerve head with laser tomographic scanning.

Authors:  F E Kruse; R O Burk; H E Völcker; G Zinser; U Harbarth
Journal:  Ophthalmology       Date:  1989-09       Impact factor: 12.079

4.  Vertical optic disk diameter: discrepancy between planimetric and SLO measurements.

Authors:  A F Spencer; S A Sadiq; P Pawson; S A Vernon
Journal:  Invest Ophthalmol Vis Sci       Date:  1995-04       Impact factor: 4.799

5.  Optic nerve head analyser and Heidelberg retina tomograph: accuracy and reproducibility of topographic measurements in a model eye and in volunteers.

Authors:  P Janknecht; J Funk
Journal:  Br J Ophthalmol       Date:  1994-10       Impact factor: 4.638

6.  Quantification of cystoid changes in diabetic maculopathy.

Authors:  O Arend; A Remky; A E Elsner; B Bertram; M Reim; S Wolf
Journal:  Invest Ophthalmol Vis Sci       Date:  1995-03       Impact factor: 4.799

7.  Test-retest variability of topographic measurements with confocal scanning laser tomography in patients with glaucoma and control subjects.

Authors:  B C Chauhan; R P LeBlanc; T A McCormick; J B Rogers
Journal:  Am J Ophthalmol       Date:  1994-07-15       Impact factor: 5.258

8.  Reproducibility of the optic nerve head topography with a new laser tomographic scanning device.

Authors:  K Rohrschneider; R O Burk; F E Kruse; H E Völcker
Journal:  Ophthalmology       Date:  1994-06       Impact factor: 12.079

9.  Effect of repetitive imaging on topographic measurements of the optic nerve head.

Authors:  R N Weinreb; M Lusky; D U Bartsch; D Morsman
Journal:  Arch Ophthalmol       Date:  1993-05

10.  Reproducibility of topographic measurements of the macula with a scanning laser ophthalmoscope.

Authors:  A V Menezes; M Giunta; L Chisholm; P T Harvey; R Tuli; R G Devenyi
Journal:  Ophthalmology       Date:  1995-02       Impact factor: 12.079

View more
  6 in total

Review 1.  Laser imaging of the retina.

Authors:  P F Sharp; A Manivannan; P Vieira; J H Hipwell
Journal:  Br J Ophthalmol       Date:  1999-11       Impact factor: 4.638

2.  Topographic change in the central macula coupled with contrast sensitivity loss in diabetic pregnancy.

Authors:  Sirpa Loukovaara; Mika Harju; Risto J Kaaja; Ilkka J R Immonen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-07-17       Impact factor: 3.117

3.  Sensitivity and specificity of a new scoring system for diabetic macular oedema detection using a confocal laser imaging system.

Authors:  L Tong; A Ang; S A Vernon; H J Zambarakji; A Bhan; V Sung; S Page
Journal:  Br J Ophthalmol       Date:  2001-01       Impact factor: 4.638

4.  Reproducibility of volumetric macular measurements in diabetic patients with the Heidelberg Retina Tomograph.

Authors:  H J Zambarakji; S A Vernon; A F Spencer; W M Amoaku
Journal:  Doc Ophthalmol       Date:  1999       Impact factor: 2.379

Review 5.  A reference standard for the measurement of macular oedema.

Authors:  K A Goatman
Journal:  Br J Ophthalmol       Date:  2006-09       Impact factor: 4.638

6.  Improvement of reproducibility of macular volume measurements using the Heidelberg retinal tomograph.

Authors:  A Ang; L Tong; S A Vernon
Journal:  Br J Ophthalmol       Date:  2000-10       Impact factor: 4.638

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.