Dual-energy X-ray absorptiometry is the gold standard for evaluating Bone Mineral Density (BMD); however, a typical BMD report is generated in a time-inefficient manner and is prone to error. We developed a rule-based automated reporting system, BatchBMD, that accelerates DXA reporting while improving its accuracy over current systems. BatchBMD generates a structured report, customized to the specific clinical purpose. To compare BatchBMD to a Web-based Reporting (WBR) system for efficiency and accuracy, 500 examinations were randomly chosen from those performed at the Taipei Municipal Wanfang Hospital from January to March 2021. The final assessment included all 2326 examinations conducted from September 2020 to March 2021. The average reporting times were 6.7 and 10.8 min for BatchBMD and the WBR system, respectively, while accuracy was 99.4% and 98.2%, respectively. Most of the errors made by BatchBMD were digit errors in the appendicular skeletal muscle index. After correcting this, 100% accuracy across all 2326 examinations was validated. This automated and accurate BMD reporting system significantly reduces report production workload for radiologists and technicians while increasing productivity and quality. Additionally, the portable software, which employs a simple framework, can reduce deployment costs in clinical practice.Entities:
Keywords: automated reporting system; bone mineral density; dual-energy X-ray absorptiometry
Year: 2021 PMID: 34943639 PMCID: PMC8700356 DOI: 10.3390/diagnostics11122403
Source DB: PubMed Journal: Diagnostics (Basel) ISSN: 2075-4418
Figure 1Data flow diagram.
Figure 2Data structure of the Patient object in BatchBMD.
Figure 3Reporting time computation. (a) The report flow for BatchBMD; (b) The report flow for a WBR system.
Accuracy of auto-filled items during evaluation (500 scans) of BatchBMD, compared to a Web-based Reporting system.
| Auto-Filled Item Type | Report Accuracy | |
|---|---|---|
| BatchBMD | WBR | |
| Patient profile (6) | 100.0% | 100.0% |
| Lumbar spine BMD info (4) | 100.0% | 99.8% |
| Femur BMD info (4) | 100.0% | 100.0% |
| Forearm BMD (2) | 100.0% | 100.0% |
| LVA, vertebral compression fractures (1) | 100.0% | 98.2% |
| Lowest T-score (1) | 100.0% | 99.8% |
| Densitometric assessment (1) | 100.0% | 98.2% |
| Fracture risk analysis (2) | 100.0% | N/A |
| BMD Follow-up (2) | 100.0% | N/A |
| Body composition (11) | 99.4% | 100.0% |
| Body composition assessment (7) | 100.0% | N/A |
Abbreviations: WBR, Web-based reporting; BMD, bone mineral density; LVA, lateral vertebral assessment; N/A, not applicable.
Figure 4Average (95% confidence interval) reporting time for the two systems.