Literature DB >> 22399206

Quantitative computed tomography (QCT) as a radiology reporting tool by using optical character recognition (OCR) and macro program.

Young Han Lee1, Ho-Taek Song, Jin-Suck Suh.   

Abstract

The objectives are (1) to introduce a new concept of making a quantitative computed tomography (QCT) reporting system by using optical character recognition (OCR) and macro program and (2) to illustrate the practical usages of the QCT reporting system in radiology reading environment. This reporting system was created as a development tool by using an open-source OCR software and an open-source macro program. The main module was designed for OCR to report QCT images in radiology reading process. The principal processes are as follows: (1) to save a QCT report as a graphic file, (2) to recognize the characters from an image as a text, (3) to extract the T scores from the text, (4) to perform error correction, (5) to reformat the values into QCT radiology reporting template, and (6) to paste the reports into the electronic medical record (EMR) or picture archiving and communicating system (PACS). The accuracy test of OCR was performed on randomly selected QCTs. QCT as a radiology reporting tool successfully acted as OCR of QCT. The diagnosis of normal, osteopenia, or osteoporosis is also determined. Error correction of OCR is done with AutoHotkey-coded module. The results of T scores of femoral neck and lumbar vertebrae had an accuracy of 100 and 95.4 %, respectively. A convenient QCT reporting system could be established by utilizing open-source OCR software and open-source macro program. This method can be easily adapted for other QCT applications and PACS/EMR.

Entities:  

Mesh:

Year:  2012        PMID: 22399206      PMCID: PMC3491163          DOI: 10.1007/s10278-012-9464-8

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  7 in total

1.  A simple method for importing multiple image files into PowerPoint.

Authors:  Chris Sistrom; Janice Honeyman-Buck
Journal:  AJR Am J Roentgenol       Date:  2004-06       Impact factor: 3.959

2.  Efficient radiologic reading environment by using an open-source macro program as connection software.

Authors:  Young Han Lee
Journal:  Eur J Radiol       Date:  2010-12-15       Impact factor: 3.528

3.  Simple method for inserting Flash movies into PowerPoint presentations.

Authors:  Chun-Shan Yam
Journal:  AJR Am J Roentgenol       Date:  2007-04       Impact factor: 3.959

Review 4.  Quantitative computed tomography.

Authors:  Judith E Adams
Journal:  Eur J Radiol       Date:  2009-08-13       Impact factor: 3.528

5.  Automated extraction of radiation dose information from CT dose report images.

Authors:  Xinhua Li; Da Zhang; Bob Liu
Journal:  AJR Am J Roentgenol       Date:  2011-06       Impact factor: 3.959

Review 6.  Assessment of fracture risk and its application to screening for postmenopausal osteoporosis. Report of a WHO Study Group.

Authors: 
Journal:  World Health Organ Tech Rep Ser       Date:  1994

7.  The diagnosis of osteoporosis.

Authors:  J A Kanis; L J Melton; C Christiansen; C C Johnston; N Khaltaev
Journal:  J Bone Miner Res       Date:  1994-08       Impact factor: 6.741

  7 in total
  3 in total

1.  Development of an Automated Bone Mineral Density Software Application: Facilitation Radiologic Reporting and Improvement of Accuracy.

Authors:  I-Ta Tsai; Meng-Yuan Tsai; Ming-Ting Wu; Clement Kuen-Huang Chen
Journal:  J Digit Imaging       Date:  2016-06       Impact factor: 4.056

2.  Detection and Correction of Laterality Errors in Radiology Reports.

Authors:  Young Han Lee; Jaemoon Yang; Jin-Suck Suh
Journal:  J Digit Imaging       Date:  2015-08       Impact factor: 4.056

3.  BatchBMD as an Efficient and Accurate Dual-Energy X-ray Absorptiometry Report Generator.

Authors:  Chun-Hsiang Chan; Wen-Chi Huang; Yi-Chien Lu; Hsing-Fen Hsiao; Wing P Chan
Journal:  Diagnostics (Basel)       Date:  2021-12-20
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.