| Literature DB >> 30038639 |
Arun George Paul1,2, Adrian Nalichowski3, Judith Abrams2,3, Peter Paximadis2, Ling Zhuang2, Steven Miller2.
Abstract
PURPOSE: External beam radiation therapy (EBRT) and brachytherapy (BT) with concurrent cisplatin is the standard of care for locally advanced cervical cancer. The applicability of image-guided adaptive volume-based high-dose-rate (HDR) intracavitary brachytherapy planning is an active area of investigation. In this study, we examined whether volume-based HDR-BT (HDRVOL) plans leads to more conformal plans compared to Point A (HDRPointA)-based plans.Entities:
Keywords: HDR; Point A; brachytherapy; cervical cancer; image-guided; radiation-planning
Year: 2018 PMID: 30038639 PMCID: PMC6052381 DOI: 10.5114/jcb.2018.76782
Source DB: PubMed Journal: J Contemp Brachytherapy ISSN: 2081-2841
Population characteristics
| Parameters | |
|---|---|
| Age at diagnosis (years), median (IQR) | 49 (40, 59) |
| Race | |
| AA | 36 (75%) |
| Non-AA | 12 (25%) |
| Stage | |
| IB1 | 5 (11%) |
| IB2 | 12 (25%) |
| IIA2 | 3 (6%) |
| IIB | 14 (29%) |
| IIIA | 2 (4%) |
| IIIB | 11 (23%) |
| IVA | 1 (2%) |
| Pathology | |
| Squamous cell carcinoma | 42 (88%) |
| Adenocarcinoma | 2 (4%) |
| Others | 4 (8%) |
| Follow-up (months), median (IQR) | 13 (6, 27) |
N – total number of patients; AA – African American
Radiation therapy characteristics
| Parameters | |
|---|---|
| EBRT dose | |
| 45 Gy | 48 (100%) |
| EBRT modality | |
| 3DRT | 24 (50%) |
| IMRT | 24 (50%) |
| Sidewall boost | |
| # of patients | 32 (67%) |
| Modality | |
| 3DRT | 32 (67%) |
| Dose (Gy) | |
| 1.8 | 1 (2%) |
| 5.4 | 25 (52%) |
| 9 | 6 (13%) |
| Nodal boost | |
| # of patients | 25 (52%) |
| Modality | |
| 3DRT | 8 (17%) |
| IMRT | 14 (29%) |
| 3DRT & IMRT | 3 (6%) |
| Dose (Gy) | |
| 3.6 | 2 (4.2%) |
| 4 | 1 (2.1%) |
| 6 | 4 (8.3%) |
| 7.5 | 1 (2.1%) |
| 8 | 2 (4.2%) |
| 9 | 3 (6.3%) |
| 10 | 1 (2.1%) |
| 10.8 | 5 (10.4%) |
| 12.6 | 1 (2.1%) |
| 14 | 2 (4.2%) |
| 14.4 | 1 (2.1%) |
| 16 | 1 (2.1%) |
| 19.6 | 1 (2.1%) |
| Duration (days), median (IQR) | |
| RT (EBRT + brachytherapy) | 61 (53, 68) |
N – total number of patients, EBRT – external beam radiation therapy, 3D – three dimensional, IMRT – intensively modulated radiation therapy
High-dose-rate brachytherapy characteristics
| HDR-BT parameters | |
|---|---|
| HDR-BT applicators by fraction (fx) | |
| T&R × 5 fx | 45 (94%) |
| T&R × 4 fx and T&O × 1 fx | 1 (2%) |
| T&O × 5 fx | 1 (2%) |
| T&O × 3 fx and T&R × 2 fx | 1 (2%) |
| Fractionation schemes | |
| 5.5 Gy × 5 fx | 23 (48%) |
| Others | 25 (52%) |
| Point A planning strategies: | |
| Point A (2.0 cm) × 5 fx | 34 (71%) |
| Modified Point A or Point A | 14 (29%) |
| Treatment volumes (cc), median (IQR): | |
| HR-CTV | 23 (18, 33) |
| Rectum | 52 (35, 63) |
| Sigmoid | 44 (33, 64) |
| Bladder | 100 (88, 118) |
| Duration (days), median (IQR): | 17 (14, 22) |
HDR-BT – high-dose-rate brachytherapy, N – total number of patients, T&R – tandem and ring, T&O – tandem and ovoids, HR-CTV – high-risk clinical target volume
Gastrointestinal and genitourinary toxicity profile
| Status | Grade 3-4 GI toxicities | Grade 3-4 GU toxicities |
|---|---|---|
| Present | 8 (17%) | 7 (15%) |
| Absent | 35 (73%) | 36 (75%) |
| Data missing | 5 (10%) | 5 (10%) |
GI – gastrointestinal, GU – genitourinary
Dosimetric parameters of organs at risk
| OAR parameters | HDRPointA (Gy) | HDRVOL (Gy) | Relative difference (%) |
|---|---|---|---|
| D0.1(EBRT+HDR) | 73 (68, 80) | 63 (57, 70) | 10 (5, 22) |
| D1.0(EBRT+HDR) | 66 (62, 69) | 58 (53, 63) | 9 (4, 17) |
| D2.0(EBRT+HDR) | 63 (59, 66) | 56 (52, 60) | 8 (3, 15) |
| D2.0(HDR) | |||
| Fraction 1 | 2.8 (3, 4) | 2.3 (3, 3) | 19 (2, 57) |
| Fraction 2 | 2.9 (2, 3) | 2.3 (2, 3) | 23 (2, 65) |
| Fraction 3 | 3.1 (2, 4) | 1.8 (2, 3) | 34 (8, 91) |
| Fraction 4 | 2.6 (8, 3) | 1.9 (8, 2) | 37 (8, 76) |
| Fraction 5 | 2.6 (8, 3) | 1.9 (8, 3) | 31 (11, 86) |
| D0.1(EBRT+HDR) | 76 (69, 91) | 70 (61, 77) | 9 (4, 19) |
| D1.0(EBRT+HDR) | 68 (62, 76) | 62 (57, 67) | 7 (4, 14) |
| D2.0(EBRT+HDR) | 65 (59, 70) | 59 (56, 64) | 6 (3, 14) |
| D2.0(HDR) | |||
| Fraction 1 | 3.3 (3, 4) | 2.7 (3, 3) | 10 (1, 51) |
| Fraction 2 | 3.2 (1, 4) | 2.7 (1, 3) | 14 (2, 48) |
| Fraction 3 | 3.3 (2, 4) | 2.6 (2, 3) | 19 (5, 49) |
| Fraction 4 | 3.3 (5, 4) | 2.5 (5, 3) | 26 (6, 49) |
| Fraction 5 | 3.1 (6, 4) | 2.6 (6, 3) | 25 (10, 45) |
| D0.1(EBRT+HDR) | 91 (74, 103) | 78 (69, 90) | 12 (5, 24) |
| D1.0(EBRT+HDR) | 79 (68, 86) | 68 (62, 75) | 10 (5, 18) |
| D2.0(EBRT+HDR) | 74 (66, 80) | 66 (59, 71) | 10 (4, 16) |
| D2.0(HDR): | |||
| Fraction 1 | 3.8 (4, 5) | 3.1 (4, 4) | 8 (1, 45) |
| Fraction 2 | 4.3 (1, 5) | 3.1 (1, 4) | 15 (2, 52) |
| Fraction 3 | 4.1 (2, 5) | 3.1 (2, 4) | 21 (4, 53) |
| Fraction 4 | 3.6 (4, 5) | 3.2 (4, 4) | 23 (7, 45) |
| Fraction 5 | 4.0 (7, 5) | 3.2 (7, 4) | 22 (9, 45) |
OAR – organs at risk, HDRPointA – conventional Point A or modified Point A plan, HDRVOL – image-guided adaptive volume-based HDR-BT planning, D0.1(EBRT+HDR) – total EQD2 dose to 0.1 cc from the combination of EBRT and HDR-BT, D1.0(EBRT+HDR) – total EQD2 dose to 1.0 cc from the combination of EBRT and HDR-BT; D2.0(EBRT+HDR) – total EQD2 dose to 2.0 cc from the combination of EBRT and HDR-BT; D2.0(HDR) – dose to 2.0 cc per HDR-BT fraction
Dosimetric parameters of high-risk clinical target volume
| HR-CTV | HDRPointA | HDRVOL | Relative difference (%) |
|---|---|---|---|
| V150(HDR) (%) | |||
| Fraction 1 | 73 (62, 88) | 62 (55, 67) | 9 (2, 39) |
| Fraction 2 | 73 (60, 90) | 63 (58, 67) | 12 (1, 38) |
| Fraction 3 | 72 (64, 89) | 62 (57, 65) | 13 (3, 41) |
| Fraction 4 | 79 (64, 89) | 65 (59, 68) | 20 (3, 37) |
| Fraction 5 | 79 (71, 89) | 63 (58, 67) | 24 (5, 44) |
| V200(HDR) (%) | |||
| Fraction 1 | 47 (39, 63) | 39 (33, 45) | 10 (1, 53) |
| Fraction 2 | 48 (38, 66) | 40 (37, 45) | 14 (1, 52) |
| Fraction 3 | 46 (40, 58) | 40 (35, 43) | 15 (0, 51) |
| Fraction 4 | 55 (41, 66) | 41 (36, 45) | 22 (1, 62) |
| Fraction 5 | 54 (44, 60) | 41 (36, 44) | 30 (1, 53) |
| D90(EBRT+HDR) (Gy) | 98 (91, 105) | 86 (84, 87) | 11 (4, 22) |
V150(HDR) – percentage of HR-CTV receiving 150% of the prescription dose per HDR-BT fraction, V200(HDR) – percentage of HR-CTV receiving 200% of the prescription dose per HDR-BT fraction, D90(EBRT+HDR) – dose to 90% of the HR-CTV from the combination of EBRT and HDR-BT
Conformal index per high-dose-rate brachytherapy fraction
| HDR-BT fraction | HDRPointA | HDRVOL | Relative difference (%) |
|---|---|---|---|
| 1 | 0.35 (0.25, 0.40) | 0.44 (0.38, 0.52) | –18 (–46, –1) |
| 2 | 0.29 (0.22, 0.41) | 0.44 (0.39, 0.50) | –28 (–50, –2) |
| 3 | 0.32 (0.22, 0.39) | 0.48 (0.39, 0.54) | –29 (–49, –10) |
| 4 | 0.29 (0.22, 0.40) | 0.47 (0.38, 0.55) | –29 (–48, –6) |
| 5 | 0.31 (0.25, 0.38) | 0.46 (0.40, 0.55) | –31 (–48, –12) |