Dosimetric evaluation of image based brachytherapy using tandem ovoid and tandem ring applicators.

Ramya Rangarajan1.   

Abstract

AIM: The aim of the study is to evaluate the differences in dosimetry between tandem-ovoid and tandem-ring gynaecologic brachytherapy applicators in image based brachytherapy.
BACKGROUND: Traditionally, tandem ovoid applicators were used to deliver dose to tumor in intracavitary brachytherapy. Tandem-ring, tandem-cylinder and hybrid intracavitary, interstitial applicators are also used nowadays in cervical cancer brachytherapy. METHODS AND MATERIALS: 100 CT datasets of cervical cancer patients (stage IB2 - IIIB) receiving HDR application (50 tandem-ovoid and 50 tandem-ring) were studied. Brachytherapy was delivered using a CT-MRI compatible tandem-ovoid (50 patients) and a tandem-ring applicator (50 patients). DVHs were calculated and D2cc was recorded for the bladder and rectum and compared with the corresponding ICRU point doses. The point B dose, the treated volume, high dose volume and the treatment time were recorded and compared for the two applicators.
RESULTS: The mean D2cc of the bladder with TR applicator was 6.746 Gy. TO applicator delivered a mean D2cc of 7.160 Gy to the bladder. The mean ICRU bladder points were 5.60 and 5.63 Gy for TR and TO applicator, respectively. The mean D2cc of the rectum was 4.04 Gy and 4.79 Gy for TR and TO applicators, respectively. The corresponding ICRU point doses were 5.10 Gy and 5.66 Gy, respectively.
CONCLUSIONS: The results indicate that the OAR doses assessed by DVH criteria were higher than ICRU point doses for the bladder with both tandem-ovoid and tandem-ring applicators whereas DVH based dose was lower than ICRU dose for the rectum. The point B dose, the treated volume and high dose volume was found to be slightly higher with the tandem-ovoid applicator. The mean D2cc dose for the bladder and rectum was lower with tandem-ring applicators. The clinical implication of the above dosimetric differences needs to be evaluated further.

Entities:  

Keywords:  Intracavitary brachytherapy; Tandem-ovoid; Tandem-ring

Year:  2018        PMID: 29348735      PMCID: PMC5767844          DOI: 10.1016/j.rpor.2017.12.006

Source DB:  PubMed          Journal:  Rep Pract Oncol Radiother        ISSN: 1507-1367


  8 in total

1.  The American Brachytherapy Society recommendations for high-dose-rate brachytherapy for carcinoma of the cervix.

Authors:  S Nag; B Erickson; B Thomadsen; C Orton; J D Demanes; D Petereit
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-08-01       Impact factor: 7.038

2.  Spatial reproducibility of the ring and tandem high-dose rate cervix applicator.

Authors:  J H Bahena; A Martinez; D Yan; E Mele; G Edmunson; D Brown; M Hardy; D Brabbins; G Gustafson
Journal:  Int J Radiat Oncol Biol Phys       Date:  1998-04-01       Impact factor: 7.038

3.  High dose rate (HDR) brachytherapy technique: for carcinoma of uterine cervix using Nucletron applicators.

Authors:  M T Nair; M C Cheng; A Barker; B S Rouse
Journal:  Med Dosim       Date:  1995       Impact factor: 1.482

4.  Computed tomography versus magnetic resonance imaging-based contouring in cervical cancer brachytherapy: results of a prospective trial and preliminary guidelines for standardized contours.

Authors:  Akila N Viswanathan; Johannes Dimopoulos; Christian Kirisits; Daniel Berger; Richard Pötter
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-02-27       Impact factor: 7.038

5.  Clinical impact of computed tomography-based image-guided brachytherapy for cervix cancer using the tandem-ring applicator - the Addenbrooke's experience.

Authors:  L T Tan; C E Coles; C Hart; E Tait
Journal:  Clin Oncol (R Coll Radiol)       Date:  2008-12-19       Impact factor: 4.126

6.  Dosimetric comparison of tandem and Ovoids vs. tandem and ring for intracavitary gynecologic applications.

Authors:  Daphne Levin; Janna Menhel; Tanya Rabin; M Raphael Pfeffer; Zvi Symon
Journal:  Med Dosim       Date:  2008-07-01       Impact factor: 1.482

7.  Short-term clinical outcome and dosimetric comparison of tandem and ring versus tandem and ovoids intracavitary applicators.

Authors:  John K Ma; Waleed F Mourad; Robert Allbright; Satyaseelan Packianathan; Leslie M Harrell; Edmund Chinchar; Alex Nguyen; Srinivasan Vijayakumar
Journal:  J Contemp Brachytherapy       Date:  2015-05-28

8.  The variability of applicator position among high dose rate intracavitary brachytherapy applications in cervical cancer patients treated with ring & tandem applicators.

Authors:  Cuneyt Ebruli; Ayşe Nur Demiral; Riza Cetingöz; Ferhat Eyiler; Münir Kinay
Journal:  Tumori       Date:  2007 Sep-Oct
  8 in total
  3 in total

1.  Dosimetric evaluation of Point A and volume-based high-dose-rate plans: a single institution study on adaptive brachytherapy planning for cervical cancer.

Authors:  Arun George Paul; Adrian Nalichowski; Judith Abrams; Peter Paximadis; Ling Zhuang; Steven Miller
Journal:  J Contemp Brachytherapy       Date:  2018-06-28

2.  A comparison of tandem ring and tandem ovoid treatment as a curative brachytherapy component for cervical cancer.

Authors:  Sukriye Bilge Gursel; Alparslan Serarslan; Ahmet Deniz Meydan; Nilgun Okumus; Tenzile Yasayacak
Journal:  J Contemp Brachytherapy       Date:  2020-04-08

3.  Dosimetric comparison of two different applicators and rectal retraction methods used in inverse optimization-based intracavitary brachytherapy for cervical cancer.

Authors:  Fatih Biltekin; Melis Gultekin; Melek Tugce Yilmaz; Ferah Yildiz
Journal:  J Contemp Brachytherapy       Date:  2020-02-28
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.