| Literature DB >> 27138378 |
Hui Chen1, Haotian Lin1, Zhuoling Lin1, Jingjing Chen1, Weirong Chen2.
Abstract
BACKGROUND: Ocular biometry is important for preoperative assessment in cataract and anterior segment surgery. The purpose of this study was to investigate normative ocular biometric parameters and their associations in an older Chinese population.Entities:
Keywords: Anterior chamber depth; Axial length; Corneal curvature
Mesh:
Year: 2016 PMID: 27138378 PMCID: PMC4852406 DOI: 10.1186/s12886-016-0221-5
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Fig. 1Summary of the trial design
Age and gender distribution of ocular biometry measures with 95 % confidence intervals
| CC(D) | |||||||
|---|---|---|---|---|---|---|---|
| Age group(years) |
| AL(mm) | ACD(mm) | K1 | K2 | K | ΔK |
| Gender | |||||||
| Men | |||||||
| 50–59 | 80 | 23.61(20.93–28.84) | 3.14(2.27–4.01) | 43.75(40.08–46.68) | 44.43(41.11–48.28) | 44.08(40.59–47.47) | 0.68(0.06–3.05) |
| 60–69 | 244 | 23.83(20.89–30.34) | 3.15(2.27–4.01) | 43.41(36.49–49.06) | 44.21(41.16–50.45) | 43.81(40.23–49.74) | 0.80(0.00–8.33) |
| 70–79 | 117 | 23.97(21.40–29.03) | 3.13(1.97–4.16) | 43.26(39.57–47.07) | 44.25(40.56–48.35) | 43.75(40.30–47.70) | 0.99(0.11–3.57) |
| 80+ | 26 | 23.54(22.03–24.92) | 2.91(1.90–3.59) | 43.23(39.99–46.30) | 44.86(42.94–47.8) | 44.02(41.46–46.97) | 1.63(0.29–3.14) |
| All | 467 | 23.81(20.89–30.34) | 3.13(1.90–4.16) | 43.42(36.49–49.06) | 44.29(40.56–50.45) | 43.85(40.23–49.74) | 0.87(0.00–8.33) |
| Women | |||||||
| 50–59 | 117 | 23.04(20.88–31.15) | 2.93(2.14–4.10) | 44.16(40.42–48.49) | 44.92(42.45–49.71) | 44.54(42.06–49.09) | 0.76(0.00–4.64) |
| 60–69 | 289 | 23.22(20.62–29.27) | 2.96(2.14–4.10) | 44.11(40.76–47.94) | 44.89(41.31–49.41) | 44.49(41.03–48.35) | 0.78(0.00–3.42) |
| 70–79 | 129 | 23.26(21.53–29.23) | 2.96(2.19–3.95) | 43.98(40.27–48.01) | 44.92(40.52–49.56) | 44.44(40.39–48.77) | 0.94(0.16–3.81) |
| 80+ | 13 | 23.13(22.27–24.54) | 2.88(2.28–3.62) | 44.25(41.36–49.13) | 45.18(42.24–50.22) | 44.71(41.80–49.67) | 0.93(0.24–2.38) |
| All | 548 | 23.19(20.62–31.15) | 2.95(2.14–4.10) | 44.09(40.27–49.13) | 44.91(40.52–50.22) | 44.50(40.39–49.67) | 0.82(0.00–4.64) |
| Whole population | |||||||
| 50–59 | 197 | 23.27(20.88–31.15) | 3.02(2.14–4.10) | 43.99(40.08–48.49) | 44.72(41.11–49.71) | 44.35(40.59–49.09) | 0.73(0–4.64) |
| 60–69 | 533 | 23.50(20.62–30.34) | 3.04(2.10–4.01) | 43.64(36.49–49.06) | 44.58(41.16–50.45) | 44.18(40.23–49.74) | 0.79(0–8.33) |
| 70–79 | 246 | 23.60(21.40–29.23) | 3.04(1.97–4.16) | 43.57(39.57–48.01) | 44.60(40.52–49.56) | 44.11(40.30–48.77) | 0.96(0.11–3.81) |
| 80+ | 39 | 23.41(22.03–24.92) | 2.90(1.90–3.62) | 43.78(39.99–49.13) | 44.96(42.24–50.22) | 44.25(41.46–49.67) | 1.40(0.24–3.14) |
| All | 1015 | 23.48(23.40–23.55) | 3.03(3.01–3.05) | 43.79(43.70–43.87) | 44.63(44.54–44.72) | 44.20(44.11–44.29) | 0.84(0.80–0.88) |
ACD anterior chamber depth, AL axial length, CC corneal curvature, D diopters, mm millimeters
Fig. 2Distribution of axial length, anterior chamber depth, and corneal curvatures
Fig. 3Frequency distribution of the sample by age group
Mean axial length, anterior chamber depth, corneal and curvature radius reported in population-based studies
| AL | ACD | CC | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Study | Ethnicity | Measurement | Men | Women | All | Men | Women | All | Men | Women | All |
| The Los Angeles Latino Eye Study | Latinos | Ultrasound | 23.65 | 23.18 | 23.38 | 3.48 | 3.36 | 3.41 | 43.35 | 43.95 | 43.72 |
| The Mongolian Study | Mongolians | Ultrasound | 23.43 | 23.08 | 23.13 | 2.87 | 2.77 | 43.65 | 44.24 | ||
| The Beaver Dam Eye Study | white | IOL Master | 23.92 | 23.51 | 23.69 | 3.14 | 3.09 | 3.11 | 7.77a | 7.65a | 7.70a |
| The Meiktila Eye Study | Burmese | Ultrasound | 23.12 | 22.54 | 22.76 | 2.86 | 2.79 | 2.82 | 7.71a | 7.56a | 7.62a |
| The Reykjavik Study | White | Ultrasound | 23.74 | 23.20 | 3.20 | 3.08 | 43.41 | 43.73 | |||
| The Liwan Eye Study | Chinese | Ultrasound | 23.38 | 22.83 | 23.11 | 2.75 | 2.61 | 2.67 | 43.50 | 44.25 | 43.88 |
| The tanjong pagar study | Chinese | Ultrasound | 23.54 | 22.98 | 23.23 | 2.99 | 2.81 | 2.90 | 7.73a | 7.59a | 7.65a |
| The Singapore Malay Eye Study | Malay | IOL Master | 23.55 | 3.10 | 7.65a | ||||||
| The Singapore Indian Eye Study | Indians | IOL Master | 23.68 | 23.23 | 23.45 | 3.19 | 3.10 | 3.15 | 7.68a | 7.55a | 7.61a |
| The blue mountain eye study | white | IOL Master | 23.75 | 23.20 | 23.44 | 3.16 | 3.06 | 3.10 | 43.01 | 43.74 | 43.42 |
ACD anterior chamber depth, AL axial length, CC corneal curvature;
aCorneal curvature in mm