Literature DB >> 10831895

Intraocular lens power calculations in patients with extreme myopia.

R Zaldivar1, M C Shultz, J M Davidorf, J T Holladay.   

Abstract

PURPOSE: To determine the variables that might contribute to improved intraocular lens (IOL) power calculations preoperatively in cataract patients with extreme myopia.
METHODS: This retrospective study included 50 patients with extreme myopia and axial lengths longer than 27.0 mm. All patients had clear corneal phacoemulsification by the same surgeon and implantation of the Domilens SiFlex 1 IOL (power range -6.0 to +5.0 diopters [D]). The performances of the SRK/T, Hoffer Q, Holladay 1, and Holladay 2 formulas in predicting an IOL power that would meet the target refraction of +/-1.00 D were compared.
RESULTS: The formulas tended to suggest underpowered IOLs, more severe in eyes with axial lengths greater than 30.00 mm. These eyes accounted for most of the minus-power IOLs implanted. Back calculations of axial lengths in patients with minus-power IOLs showed that, on average, emmetropia could have been predicted by choosing shorter axial lengths (up to 2.72 mm shorter) than those used in the original IOL power calculations. Preoperative B-scan ultrasonography demonstrated the presence of a posterior pole staphyloma temporal to the optic nerve in several patients who required minus-power IOLs, which suggests that axial length measurement problems were a major source of IOL calculation errors in these patients.
CONCLUSIONS: In eyes with axial lengths longer than or equal to 27.0 mm, current third- and fourth-generation lens calculation formulas have a tendency to over minus patients between -1.0 and -4.0 D. The formulas appear to perform better for plus-power IOL implantation than for minus-power IOL implantation. The use of B-scan ultrasonography to locate posterior pole staphylomas may improve the accuracy of IOL calculations in eyes with extreme myopia.

Entities:  

Mesh:

Year:  2000        PMID: 10831895     DOI: 10.1016/s0886-3350(00)00367-9

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  21 in total

Review 1.  Management of cataract surgery in a high myope.

Authors:  H Seward; R Packard; D Allen
Journal:  Br J Ophthalmol       Date:  2001-11       Impact factor: 4.638

2.  Comparison of formulas and methods for high myopia patients requiring intraocular lens powers less than six diopters.

Authors:  Harry S Geggel
Journal:  Int Ophthalmol       Date:  2017-06-20       Impact factor: 2.031

3.  Intra-ocular lens power calculation in patients with high axial myopia before cataract surgery.

Authors:  Raouf El-Nafees; Ashraf Moawad; Hanem Kishk; Walid Gaafar
Journal:  Saudi J Ophthalmol       Date:  2010-04-04

4.  Refractive errors in high myopic eyes after phacovitrectomy for macular hole.

Authors:  Donghyun Jee; Yi-Ryeung Park; Kyoung In Jung; Eunchul Kim; Tae Yoon La
Journal:  Int J Ophthalmol       Date:  2015-04-18       Impact factor: 1.779

5.  A study to evaluate whether CTR increases refractive unpredictability between predicted and actual IOL position.

Authors:  V K Baranwal; Santosh Kumar; Avinash Mishra; Ajay K Dutta
Journal:  Med J Armed Forces India       Date:  2012-10-31

6.  [Refractive predictability and stability of three-piece versus single-piece intraocular lenses in patients with high axial myopia].

Authors:  A Frings; I Steinbrugger; E Wissiak; B Vidic; Y El-Shabrawi; N Ardjomand
Journal:  Ophthalmologe       Date:  2012-06       Impact factor: 1.059

7.  Accuracy of axial length measurements from immersion B-scan ultrasonography in highly myopic eyes.

Authors:  Qing-Hua Yang; Bing Chen; Guang-Hua Peng; Zhao-Hui Li; Yi-Fei Huang
Journal:  Int J Ophthalmol       Date:  2014-06-18       Impact factor: 1.779

8.  Evaluation of refractive error after cataract surgery in highly myopic eyes.

Authors:  Tae Yokoi; Muka Moriyama; Kengo Hayashi; Noriaki Shimada; Kyoko Ohno-Matsui
Journal:  Int Ophthalmol       Date:  2013-01-12       Impact factor: 2.031

9.  Outcomes of cataract operations in extreme high axial myopia.

Authors:  Jasmine K M Lam; Tommy C Y Chan; Alex L K Ng; Vanissa W S Chow; Victoria W Y Wong; Vishal Jhanji
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-06-16       Impact factor: 3.117

10.  Efficacy and safety of cataract extraction with negative power intraocular lens implantation.

Authors:  Michael A Kapamajian; Kevin M Miller
Journal:  Open Ophthalmol J       Date:  2008-02-15