Literature DB >> 25295176

Room-temperature serial crystallography using a kinetically optimized microfluidic device for protein crystallization and on-chip X-ray diffraction.

Michael Heymann1, Achini Opthalage2, Jennifer L Wierman3, Sathish Akella2, Doletha M E Szebenyi4, Sol M Gruner5, Seth Fraden2.   

Abstract

An emulsion-based serial crystallographic technology has been developed, in which nanolitre-sized droplets of protein solution are encapsulated in oil and stabilized by surfactant. Once the first crystal in a drop is nucleated, the small volume generates a negative feedback mechanism that lowers the supersaturation. This mechanism is exploited to produce one crystal per drop. Diffraction data are measured, one crystal at a time, from a series of room-temperature crystals stored on an X-ray semi-transparent microfluidic chip, and a 93% complete data set is obtained by merging single diffraction frames taken from different unoriented crystals. As proof of concept, the structure of glucose isomerase was solved to 2.1 Å, demonstrating the feasibility of high-throughput serial X-ray crystallography using synchrotron radiation.

Entities:  

Keywords:  X-ray diffraction; microfluidic devices; protein crystallization; serial crystallography

Year:  2014        PMID: 25295176      PMCID: PMC4174877          DOI: 10.1107/S2052252514016960

Source DB:  PubMed          Journal:  IUCrJ        ISSN: 2052-2525            Impact factor:   4.769


Introduction

In conventional protein X-ray crystallography, a complete data set is ideally obtained from a single crystal, which typically requires a relatively large crystal that has been successfully cryocooled. Serial crystallography takes the opposite approach: complete diffraction sets are assembled from a large number of individual diffraction frames acquired from small single unoriented crystals that are not cryoprotected (Guha et al., 2012 ▶; Stellato et al., 2014 ▶; Chapman et al., 2011 ▶; Boutet et al., 2012 ▶). Complete coverage of the Ewald sphere is obtained by assembling individual diffraction frames into a single data set. The ideal crystals for serial crystallography are large enough and sufficiently defect free to diffract to high resolution, are produced in large quantity, and are sufficiently identical to facilitate merging of diffraction frames. Serial crystallography with non-cryocooled crystals has several technical advantages over conventional methods. First, the crystals can be small, which increases the potential for growing crystals in the first place. Second, it avoids the roughly tenfold increase in crystal mosaicity typically encountered during cryoprotection (Malkin & Thorne, 2004 ▶; Guha et al., 2012 ▶) and eliminates the need to search for cryoprotectant conditions. Although non-cryoprotected crystals suffer radiation damage at roughly a hundred times higher rate than cryoprotected crystals (Garman, 2010 ▶), there is little dis­advantage associated with using many non-cryocooled crystals to obtain a complete data set if the crystals are easy to produce, plentiful and easy to handle. The ideal crystallization procedure, illustrated in Fig. 1 ▶(a), to produce protein crystals for any form of crystallography, including serial crystallography, consists of slowly increasing the supersaturation of a protein solution until the moment that a single crystal is nucleated. Then, once the first nucleation event occurs, the supersaturation is reduced enough to prevent further nucleation while maintaining sufficient supersaturation to grow the crystal. Ideally, the growth conditions should be slow enough to allow for annealing of defects, and the procedure must be capable of producing crystals in large numbers and of identical size. Additionally, the technology to produce crystals must be simple and inexpensive if serial crystallography is to be adopted by the structural biology community.
Figure 1

(a) An optimal crystallization trajectory increases supersaturation until just one crystal nucleates, then decreases supersaturation to prevent further nucleation while maintaining sufficient supersaturation to promote crystal growth. (b) Emulsion droplets with monodisperse crystals were stored in an X-ray semi-transparent microfluidic device. Sequentially collected diffraction frames from multiple individual crystals were merged to solve the protein structure. The chip could be translated in the x and y directions and rotated 20°.

The challenge is to design such a method. The well known counter-diffusion method (Garcia-Ruiz, 2003a ▶,b ▶; Otalora et al., 2009 ▶) produces a series of kinetic supersaturation profiles that rise and fall as illustrated in Fig. 1 ▶(a). However, both the time at which the supersaturation maximum occurs and the value of the supersaturation maximum are independent of the nucleation event. The maximum supersaturation varies along the capillary length, and with a long capillary the chances are improved that somewhere along the capillary there will be a location where the maximum supersaturation will coincide with the first nucleation event. However, this method requires long capillaries and is not optimal for volumes under 1 nl. Furthermore, counter-diffusion requires that the precipitant and protein have greatly different diffusion constants, so it is suitable for low molecular weight precipitants, such as salt, but not for macromolecules, such as poly(ethylene glycol) (PEG). Another issue complicating design of the ideal profile of Fig. 1 ▶(a) is that at constant supersaturation nucleation is a random process, rendering it impossible to know a priori when to decrease supersaturation, which should coincide with the first nucleation event. One way to generate the ideal supersaturation profile would be to monitor the supersaturated solution with a technique, such as second-harmonic generation (SHG) microscopy (Wampler et al., 2008 ▶; Kissick et al., 2010 ▶), that is sensitive to the formation of small crystals and then, once the first crystal is detected, lower the supersaturation. However, this scheme will be cumbersome to implement in the high-throughput case of processing hundreds to thousands of samples. An alternative method is desired. Microfluidically produced monodisperse emulsions have previously been used to produce drops of supersaturated protein solution in which each drop nucleates a single crystal (Zheng et al., 2003 ▶; Ildefonso et al., 2013 ▶; Selimović et al., 2010 ▶; Dombrowski et al., 2010 ▶). This situation is ideal for serial crystallography for a number of reasons. Since only one crystal nucleates per drop, all the supersaturated protein in solution is delivered to a single crystal, making that crystal as large as possible. Microfluidic precision allows preparation of emulsion droplets with variations in size of a few percent only, even at high flow rates (Romanowsky et al., 2012 ▶). Furthermore, because of the small length scales in microfluidics, convection is suppressed and flows are laminar. Taken together, these factors mean that processing proteins using microfluidics leads to crystals of a uniform size that are grown under identical conditions, which has the effect of creating crystals that have similar characteristics, such as unit cell and degree of disorder. Having identical crystals facilitates merging of diffraction data sets taken from different crystals. In the microfluidic device described here, we first produce drops containing protein. Then, exploiting surface tension forces, we guide the drops to 8000 storage sites on chip (Shim et al., 2007 ▶; Schmitz et al., 2009 ▶). Next, we increase supersaturation to induce crystallization in such a way as to produce one crystal per drop. Finally, we sequentially collect diffraction data from individual crystals and merge the data sets in order to solve the protein structure (Fig. 1 ▶ b). Producing and diffracting from crystals in the same device eliminates the laborious and potentially damaging steps of looping and extracting the crystal from the mother liquor. Various microfluidic crystallization platforms compatible with in situ diffraction have been developed (Hansen et al., 2006 ▶; Li et al., 2006 ▶; Dhouib et al., 2009 ▶; Guha et al., 2012 ▶). However, these devices incorporated valves in the chip (Hansen et al., 2006 ▶; Guha et al., 2012 ▶), thus rendering them expensive to manufacture and difficult to operate. Other technologies are low throughput (Dhouib et al., 2009 ▶) or need a second round of scale-up to larger capillaries (Li et al., 2006 ▶) to produce crystals large enough to collect diffraction data.

One crystal per drop through compartmentalization

The production of one crystal per drop is a result of a competition between two processes, nucleation and growth, in a confined volume. Both processes require supersaturation and therefore both nucleation and growth are nonequilibrium processes. When the first nucleus forms inside the drop, it decreases the supersaturation in the surrounding protein solution as the crystal grows. If the rate of nucleation is low enough, then the growing crystal will consume enough of the protein in solution to decrease the supersaturation to the point where another nucleation event is improbable. Further nucleation is prevented if the time for a protein to diffuse across a drop is less than the time to nucleate a crystal (Dombrowski et al., 2010 ▶). Thus, combining a small drop volume with the physics of nucleation and growth generates negative feedback, which acts to create autonomously the ideal dynamic supersaturation profile that produces one crystal per drop. Instead of having the negative feedback imposed externally, as in the cumbersome SHG microscopy scheme discussed previously, here the negative feedback is engineered into each drop; no external intervention is required. All the engineering goes into identifying the correct combination of diffusive flux, nucleation rate and drop volume for the emulsions. A theoretical argument and computer simulations describing the processes leading to one crystal per drop in small volumes are detailed in Appendix A .

Crystal emulsions

To yield identical crystals in sufficient quality and quantity for serial crystallography, we use a two-step method. We first identify the appropriate drop volume to nucleate one crystal per drop consistently. For this we intentionally created emulsions in a batch process that yielded a polydisperse size distribution, ranging from a few micrometres to a few hundreds of micrometres in diameter (Figs. 2 ▶ a–2 ▶ c). Such a polydisperse emulsion allowed us to identify the appropriate drop diameter in a single screening experiment. We then used microfluidics (Fig. 2 ▶ d) to produce monodisperse emulsion droplets (Figs. 2 ▶ e and 2 ▶ f), which we used to grow identical crystals in the serial X-ray diffraction chip, as described in §5. For the purposes of this paper, however, the full experimental sequence will only be reported for glucose isomerase, i.e. whereby crystals were grown in the serial diffraction chip, X-ray data were acquired and the structure was solved.
Figure 2

Protein crystallization in emulsion droplets stabilized by surfactant. Ideal drop sizes were first identified using polydisperse emulsion droplets. Monodisperse emulsions were used to produce identical crystals for diffraction experiments. Droplets were stored in a rectangular glass capillary. (a)–(c) Polydisperse emulsions of (a) D1D2 heterodimer from human spliceosomal snRNP particle, (b) concanavelin A and (c) trypsin. (d) Protein and precipitant solutions were introduced in a co-flow geometry under laminar flow conditions that prevent mixing upstream of the nozzle where both solutions became encapsulated into emulsion droplets. (e), (f) Monodisperse emulsions of (e) glucose isomerase and (f) lysozyme crystals. See main text for crystallization conditions. (d) and (f) are from Akella (2014 ▶).

All crystals were grown in emulsion droplets stabilized against coalescence with a 2%(v/v) solution of PFPE–PEG–PFPE surfactant ‘E2K0660’ (PFPE is perfluoropolyether) in HFE7500 fluorinated oil (from 3M). The surfactant was synthesized as previously described (Holtze et al., 2008 ▶). Note that a commercial surfactant, which we have used in other experiments, is now available (RAN Biotechnologies; http://www.ranbiotechnologies.com). We chose a fluorinated oil and surfactant to minimize interactions with biological molecules. Fluorocarbon and hydrocarbon oils do not mix with each other, nor do they mix with water. In particular, the PFPE–PEG–PFPE surfactant in HFE7500 oil system has been shown to have excellent biocompatibility (Holtze et al., 2008 ▶; Sanchez et al., 2012 ▶). To confirm that it is compatible with protein crystallization, we tested it with five crystallization model proteins (Fig. 2 ▶ and Table 1 ▶). All five model proteins have previously been crystallized by vapor diffusion and a structure derived from X-ray crystallography deposited in the Protein Data Bank (PDB; Berman et al., 2000 ▶).
Table 1

Properties of crystallized proteins

The theoretical pI value of D1D2 was computed using its amino acid sequence and the ExPASy ProtParam tool (http://web.expasy.org/protparam).

 Formula weight (kDa)Isoelectric point (pI)Net charge in crystal
Lysozyme14.311.3 (from Wetter & Deutsch, 1951)Positive
Trypsin2410.1–10.5 (from Walsh, 1970)Positive
Concanavalin A76.5 (3mer)4.5–5.5 (multiple isoforms, see Entlicher et al., 1971)Negative
Glucose isomerase173 (4mer)3.95 (from Vuolanto et al., 2003)Negative
D1D226.8 (heterodimer)10.6 (theoretical pI, from ProtParam)Positive
To adopt a published vapor diffusion recipe into our emulsion format we had to perform a set of pre-experiments. In traditional vapor diffusion, a small volume of protein solution is mixed with the same amount of precipitant and then sealed into a container together with a large reservoir of precipitant. The diluted protein–precipitant drop equilibrates through vapor phase diffusion with the reservoir, resulting in a concentration increase of all components in the drop by approximately a factor of two. All previously published crystallization recipes had been optimized to nucleate only a few crystals per microlitre. Our emulsion droplets have volumes of a few pico- to nanolitres each. As the probability of nucleating a crystal is proportional to the sample volume, we had to increase nucleation rates by at least two orders of magnitude. We thus prepared vapor phase and microbatch crystallization trials around the literature recipes and optimized the vapor recipes toward nucleating crystal showers of appropriate density. When attempting to crystallize a novel protein target through screening crystallization conditions, such crystal showers are usually considered a first hit and the conditions are later refined extensively to grow the largest possible crystal. When using the method presented here on a novel protein target, the polydisperse emulsion screen can be used directly with conditions giving crystallites and crystal showers commonly identified as first hits in vapor diffusion screens. This would eliminate the reverse engineering step of converting an optimized vapor phase recipe back to a recipe that grows crystal showers. Polydisperse emulsions were then prepared by mixing 2 µl of protein solution with 2 µl of precipitant in a 150 µl PCR test tube. Immediately after mixing, we added 30 µl of 2%(v/v) solution of PFPE–PEG–PFPE surfactant (E2K0660) in HFE7500 fluorinated oil. Polydisperse emulsions were formed by gently agitating the vial by hand until droplets became too small to be resolved by eye. This procedure typically gave droplets ranging from a few micrometres to a few hundreds of micrometres in diameter (Figs. 2 ▶ a–2 ▶ c). The aqueous droplets were less dense than the immersing fluorinated oil, so the droplets rose (‘creamed’) to the top of the vial within a minute. The emulsion cream was then loaded into rectangular glass capillaries (VitroTubes from VitroCom, Mountain Lakes, NJ, USA) and sealed with 5 Minute Epoxy to prevent evaporation. Crystallization was monitored over the course of a week. All compounds and proteins from commercial sources were used as received without further purification. The molecular weight and the net charge of the proteins during crystallization, as derived from the isoelectric point, are summarized in Table 1 ▶. To first order, preparing a polydisperse emulsion takes about the same time as preparing a hanging or sitting drop vapor diffusion condition. Both require three pipetting steps and a final lidding or shaking operation. We also successfully used conventional pipetting robots and 96-well plates for emulsion screening. Lysozyme was crystallized by encapsulating 30 mg ml−1 lysozyme, 100 mM sodium acetate pH 4.8, 12.5 wt% PEG 8000, 5 wt% NaCl (all Sigma Aldrich) final concentration into droplets and then incubating them at 279 K for 36 h until all droplets had nucleated crystals (Akella, 2014 ▶). This recipe was derived from a vapor phase recipe mixing 20 mg ml−1 lysozyme in 100 mM sodium acetate pH 4.8 with an equal volume of 10%(w/v) NaCl, 100 mM sodium acetate pH 4.8, 25%(v/v) ethylene glycol (Rigaku, 2013 ▶). Glucose isomerase crystals were grown at room temperature (∼298 K) within two days by preparing a crystallization batch with final concentrations of 30 mg ml−1 glucose isomerase from Streptomyces rubiginosus (from Hampton Research), 100 mM ammonium sulfate pH 7.0, 20 wt% PEG 10 000 in a 1:1 ratio (all from Sigma Aldrich). The initial vapor phase crystallization condition was taken from the Hampton Research data sheet as mixing 20–30 mg ml−1 glucose isomerase with 10–15%(w/v) PEG 4000–8000, 200 mM salt pH 6.0–9.0. Trypsin was crystallized by mixing 60 mg ml−1 trypsin (Sigma T-8253) from bovine pancreas in 10 mg ml−1 benzamidine, 3 mM CaCl2, 0.02 wt% sodium azide with 100 mM NaPO4 pH 5.9, 5.1 M ammonium acetate (all Sigma Aldrich). In this system we observed crystals within one day in the range of pH 5.9 to pH 8.6, with higher pH values having much higher nucleation rates. This recipe was derived from a vapor phase recipe mixing 60 mg ml−1 trypsin in 10 mg ml−1 benzamidine, 3 mM calcium chloride, 0.02%(w/v) sodium azide with an equal volume of 4%(w/v) PEG 4000, 200 mM lithium sulfate, 100 mM 2-(N-morpholino)ethanesulfonic acid pH 6.5, 15% ethylene glycol (Rigaku, 2013 ▶). Concanavalin A was crystallized by mixing 25 mg ml−1 concanavalin A type IV from Canavalia ensiformis in 10 mM Tris hydrochloride pH 7.4 with 100 mM Tris hydrochloride pH 8.5, 8 wt% PEG 8000 in a 1:1 ratio (all from Sigma Aldrich). For this we first set up vapor phase and microbatch trials of 20 mg ml−1 concanavalin A in 10 mM Tris pH 7.4 against the 50 conditions in the Hampton Crystal Screening Kit. From this screen we choose condition 36, with 100 mM Tris hydrochloride pH 8.5, 8%(w/v) PEG 8000, as this condition grew crystals in both vapor phase and microbatch trials. D1D2, the sub-complex from the human snRNP spliceosome core particle (PDB entry 1b34; Kambach et al., 1999 ▶), crystallized over a period of 72 h at room temperature from a crystallization batch with final concentrations of 6 mg ml−1 D1D2, 62 mM sodium citrate pH 5.2, 125 mM ammonium acetate, 9 vol.% glycerol, 26%(w/v) PEG 4000 (all Sigma Aldrich). D1D2 was purified as previously reported (Kambach et al., 1999 ▶). D1D2 was first crystallized by Kambach et al. (1999 ▶) in vapor phase by mixing equal volumes of 6 mg ml−1 D1D2 in 20 mM sodium HEPES pH 7.5, 200 mM sodium chloride and 6 mM dithiothreitol and 100 mM sodium citrate pH 5.6, 200 mM ammonium acetate, 15% glycerol, 25% PEG 4000. All globular proteins, concanavalin, glucose isomerase and trypsin, crystallized readily in vapor diffusion, microbatch and the emulsion system. The heterodimer D1D2 formed crystals in the vapor phase and the emulsion system only. In microbatch a thick protein skin grew at the droplet interphase, potentially depleting all the protein from the drop. We thus conclude that the PFPE–PEG–PFPE surfactant system is well suited to protecting protein from adsorbing at the fluoro oilwater interface and to stabilizing emulsions, making it ideal for crystallization trials. Future work should investigate the compatibility of the surfactant with other proteins. In particular, in membrane protein crystallization, the crystallization cocktail includes surfactants, which may partition to the fluoro oilwater interface and affect either the protein or emulsion stability. However, the two membrane proteins porin from Rhodobacter capsulatus and reaction center from Rhodo­pseudomonas viridis have previously been crystallized in a related fluorinated FC-40 and FC-70 oil (Li et al., 2006 ▶). All initial crystallization experiments were performed at room temperature. However, a particular protein may become unstable at too high or too low temperatures. Also, many proteins like lysozyme have temperature-sensitive nucleation rates, which one might like to exploit in crystallization trials (Akella, 2014 ▶). An ideal surfactant–oil system can hence be used in a large temperature range. To test for temperature compatibility, we prepared crystal emulsions from the PFPE–PEG–PFPE surfactant in HFE7500 oil, sealed them into rectangular glass capillaries, and incubated them in a water bath at 277 K and at 313 K. We found the emulsion droplets to be stable for at least two weeks at those two temperatures. Finally, to yield identical crystals in sufficient quantity for serial crystallography, we employed microfluidics to produce monodisperse emulsion droplets. For this we simply selected the drop-making chip appropriate to make drops of the desired diameter and used the crystallization recipe from the preceding polydisperse emulsion screen without further modification. We produced drops in a co-flow geometry designed such that the protein solution and buffer do not mix in the laminar flow upstream of the dropmaker (Fig. 2 ▶ d). Typically, injection of the oil–surfactant mixture proceeded at 600 µl h−1, while both protein and precipitant streams were pumped at equal flow rates of 300 µl h−1 to co-encapsulate both in a 1:1 mixture. Upon droplet formation, mixing inside each droplet proceeds within less than a second owing to recirculating flow that arises from shearing interactions of the fluid inside the drops with the stationary wall (Tice et al., 2003 ▶). These monodisperse emulsion droplets were then injected into and incubated in the diffraction chip to grow crystals for the X-ray diffraction experiments. To monitor crystallization, we stored emulsion droplets in two different systems. Firstly, polydisperse emulsions were usually sealed into rectangular glass capillaries, which prevented water and oil evaporation. Secondly, as our diffraction chip was made from a polymer material, we exploited its permeability to water vapor by slowly letting droplets shrink by permeation of water from the drops into the oil and also from the drops through the thin polymer-based chip. Water permeation across the polymer foil is proportional to the permeation constant of the material and inversely proportional to the foil thickness (Shim et al., 2007 ▶). In the case of the 25–75 µm-thick cyclic olefine copolymer (COC) sheets used here, the evaporative water loss amounted to a few percent per hour. When water evaporates from the drop, the solute concentrations inside the drop increase and hence the protein supersaturation also increases. As this corresponds to an increased nucleation rate, one would expect to yield a larger fraction of droplets with multiple crystals. We did not observe such an effect and attribute this to the fact that, once the first crystal nucleates, its subsequent growth reduces the supersaturation of the solution enough to prevent another crystal from nucleating. We consistently achieved one crystal per drop, which argues for the robustness of the method. Once all droplets had nucleated crystals after a few hours or days, we immersed the capillary/chip into an oil bath to prevent further evaporation (Li et al., 2006 ▶). Alternatively, we achieved equally good results with storing chips in a water bath, while having a vial filled with oil connected to the chip and all other inlets sealed.

X-ray semi-transparent chip fabrication

A detailed description of the fabrication of the microfluidic chips is given by Guha et al. (2012 ▶). An overview and modifications for in situ X-ray diffraction follow. Chips were sealed, which is colloquially referred to in the thermoplastic industry as ‘lidding’, by bonding COC or Kapton foil to both sides of the thin poly(dimethylsiloxane) (PDMS) slab containing the channels (Fig. 3 ▶). PDMS (Sylgard 184 from Dow Corning) with a 1:5 ratio of curing agent to base was molded on a standard SU8 master (McDonald et al., 2000 ▶) by squeezing the uncured PDMS resin into a thin film using a glass plate and a weight. To facilitate release of the PDMS film, the master was surface-treated with a fluorophilic coating by spin coating 1:20 Cytop CTL-809M in CTsolv.100E (both Bellex International) onto the master. We then baked the wafer for 1 h at 423 K. We placed a 30 µm-thick Mylar foil (DuPont) between the PDMS and the glass to allow for easy removal of the glass slide after PDMS curing. We pre-cured the PDMS for 4 h at room temperature before we removed the weight and transferred the complete stack into an oven to drive the curing reaction to completion at 345 K for another hour.
Figure 3

Chip fabrication. (a) PDMS resin was squeezed into a thin layer onto the SU8 master (1). After curing, a foil cover was bonded onto the featured PDMS using a silane coupling chemistry (Tang & Lee, 2010 ▶) (2). Then the reinforced PDMS film was peeled off and the chip was lidded using another foil cover (3). (b) Top view and (c) cross section of a device made from COC foil and PDMS. The cross section in (c) was obtained by cutting the chip across the storage array into two and was imaged by placing the chip edge on onto the microscope stage to magnify the cut. The chip shown here had a 5 mm-thick PDMS frame manifold for fluid interfacing where tubing could be directly inserted into the through holes in the PDMS.

We used either COC (TOPAS 5013 from Advanced Polymers) or Kapton (American Durafilm), depending on experimental requirements. COC is more brittle then Kapton but has a lower water vapor permeability. The thinnest commercial COC we used was 25 µm-thin TOPAS, while Kapton as thin as 8 µm can be purchased as bulk foil. We chemically bonded either substrate to the featured PDMS using a silane coupling chemistry (Tang & Lee, 2010 ▶). In brief, the foil and PDMS were both activated in an oxygen plasma and then each incubated separately for 25 min in an aqueous solution of a different silane: one in 1 vol.% of 3-amino­propyl­tri­methoxy­silane (APS; 97% from Aldrich) and the other in 1 vol.% of 3-glycidoxy­propyl­tri­methoxy­silane (GPS; 98%, from Aldrich). The two silanes are such that they can form an epoxy bond when brought into contact. The method works equally well with the foil treated with APS and the PMDS with GPS, or vice versa. Upon removing the foil and PDMS from the batch, we dried both with a stream of nitrogen gas and then carefully brought them into contact using tweezers to prevent trapping air bubbles between the two layers. The chip was then incubated in the oven at 345 K for 1 h to maximize chemical cross-linking. The process was repeated to lid the other side of the chip, now with a foil that had through holes at the appropriate locations for fluid inter­facing. Through holes were punched using a 0.75 mm Harrison Uni-Core biopsy punch (Ted Pella). Upon assembly the chip was surface-treated with a fluoro­philic coating to prevent protein interaction with the channel surface. For this, 1:20 Cytop CTX-109AE in CTsolv.100E (both Bellex International) was dead-end filled into the chip by plugging all outlets and slowly injecting the Cytop solution through the inlet into the chip. This causes gas bubbles trapped inside the chip to become pressurized, which prompts the gas to dissolve into the solution and also to permeate across the chip walls to result in a completely filled bubble-free device. The chip was then incubated at 363 K for at least 12 h to evaporate the solvent away and also to accelerate chemical cross-linking between the fluoropolymer and the chip surface.

In situ diffraction

We mounted the X-ray-transparent chip into a custom acrylic frame to collect diffraction data (Fig. 4 ▶). The acrylic frame was cut to shape from 3 mm-thick acrylic sheet using a 40 W CO2 Hobby Laser cutter with a 1.5′′ (1′′ = 25.4 mm) focus lens (Full Spectrum Laser). To create ports into the foil chip we drilled through holes into the acrylic frame with the laser cutter. Blunt needle tips (23 gauge) were then placed into the holes and glued into position with 5 Minute Epoxy. We connected #30 AWG poly(tetrafluoroethylene) tubing (Cole Palmer) to the needle tips using PDMS cubes with through holes punched into them by a 0.75 mm Harrison Uni-Core biopsy punch (Ted Pella). Buna O-rings, 70 durometer, size 002 (McMaster Carr), were then used to seal the foil chip to the hollow metal pins. For easy alignment the O-rings were fitted into a 1 mm-thick poly(ethyleneterephthalate) spacer that also was fabricated with the laser cutter. X-ray semi-transparent foil chips were mounted into a frame for the duration of each experiment. Each frame was held together by ten self-tapping 3/16′′ Pan Head 2-28 Phillips screws (McMaster Carr) to lock the chip into position and to minimize flow induced inside the chip from mechanical bending of the thin-foil chip. To mount the frame–chip assembly in the synchrotron we machined a stainless steel adapter that a frame could be mounted onto using two screws (Fig. 4 ▶ b).
Figure 4

(a) Monodisperse emulsions were prepared using a dedicated dropmaking chip as illustrated in Fig. 2 ▶(d) and directly routed into the chip for serial crystallography for storage. (b) We used a laser-cut frame to hold and to port into the X-ray semi-transparent chip. (c) The X-ray semi-transparent chip mounted on the goniometer inside the Cornell CHESS F1 beamline. (d) Glucose isomerase crystals inside of the microfluidic device. Using a motorized stage, each crystal can be centered in the collimated X-ray beam. The beam is 100 µm in diameter. (e) A representative diffraction pattern of a glucose isomerase crystal taken at room temperature from inside the chip. Crystals diffracted to 1.4 Å resolution with a mosaicity as low as 0.04°. The bottom-right quadrant shows the diffraction pattern after background subtraction, using the Adxv diffraction pattern visualization tool (http://www.scripps.edu/~arvai/adxv.html) with subtract background option.

For the proof-of-principle experiment we fabricated an X-ray semi-transparent chip with the ‘dropspot’ geometry (Schmitz et al., 2009 ▶) that can hold up to 8000 emulsion droplets in cavities with 150 µm diameter each (Figs. 3 ▶ b and 3 ▶ c). The fluorinated oil has a density of 2 g ml−1, while the water drops have a density of 1 g ml−1. Thus there is a strong tendency for the drops to float to the top of the oil, or ‘cream’. Surface tension forces arrest droplets in a cavity and prevent them from creaming to one side of the chip. We produced a monodisperse ∼110 µm-diameter emulsion of 30 mg ml−1 glucose isomerase, 100 mM ammonium sulfate pH 7.3, 20 wt% PEG 10 000 M W final concentration in a standard dropmaker (Fig. 2 ▶ d). Droplets exiting the dropmaker were immediately routed into the X-ray semi-transparent serial crystallography chip by simply plumbing the dropmaker outlet into the dropspot inlet (Fig. 4 ▶ a). After the dropspot chip was loaded, we dead-end plugged its outlet except for one inlet where we kept HFE7500 oil entering the chip using hydrostatic pressure to compensate for oil evaporation from the chip. We incubated the chip at room temperature for three days and monitored crystallization, before transferring into a water bath to prevent further evaporation. By then, most droplets had shrunk to about ∼90 µm diameter and more than 90% of them had nucleated a single crystal. Crystals grew to about 50 × 40 × 30 µm in size at room temperature (∼298 K). X-ray diffraction data were collected at Cornell High Energy Synchrotron Source, beamline F1 ( = 0.9179 Å, = 13.508 keV, X-ray flux = 5.53 × 1010 photons s−1), using a 100 µm monochromatic X-ray beam from a 24-pole wiggler. The chips were mounted at a distance of 200 mm from an Area Detector Systems Corporation Quantum 270 detector, corresponding to a largest inscribed circle of resolution of 1.4 Å. The detector face was oriented perpendicular to the beam. For selected crystals within the chip, data sets were collected at room temperature (∼295 K). Each recorded data set comprised ten frames, for a total of 10° oscillation. Each image consisted of a 5 s exposure with a 1° oscillation step size. A total of 1520 images were collected from 152 glucose isomerase crystals in three different dropspot chips.

X-ray structure determination

The software HKL-2000 was used to index, refine, integrate and scale each 10° data set (Otwinowski & Minor, 1997 ▶) before merging. Parameters including unit-cell size, χ2 values, resolution, mosaicity and completeness were evaluated for every partial data set during the indexing and scaling process. From these partial data sets, with 1520 frames total, we selected 262 frames from 72 crystals by rejecting frames with a mosaic spread higher than 0.1° and χ2 and (corresponding to the discrepancy between observed and predicted spot positions) above 2. Some frames were later rejected because of poor scaling statistics; the final data set included 248 frames. Glucose isomerase crystals were determined to have a space group of I222 and diffracted to an average of 2 Å; an example image is shown in Fig. 4 ▶(e). In some crystals, diffraction extended to 1.4 Å, with a mosaic spread of 0.04. The 248 selected frames were scaled together using SCALEPACK (HKL Research, Charlottesville, VA, USA) and merged with Aimless (Evans, 2011 ▶). The limiting resolution of 2.09 Å was chosen as that at which CC1/2 dropped below 0.5. Statistics are given in Table 2 ▶. The merged data set covered 93% of reciprocal space, suggesting that preferred orientation of the crystals was not a major problem. The glucose isomerase structure was readily solved by molecular replacement with MOLREP (Vagin & Teplyakov, 1997 ▶) using the structure previously determined at 1.90 Å resolution (PDB entry 8xia; Carrel et al., 1989 ▶), with water molecules removed. Prior to refinement, we randomly flagged 5% of the reflections for analysis (Brunger, 1992 ▶).
Table 2

Processing results of merging the 248 frames obtained from 72 glucose isomerase crystals

Values in parentheses refer to the highest resolution bin (2.15–2.09 Å).

Precipitant composition100 mM ammonium sulfate pH 7.0 + 20 wt% PEG 10 000
Space group I222
Unit-cell parameters (Å) a = 93.94, b = 99.47, c = 102.85
Resolution range (Å)49.7–2.09 (2.15–2.09)
No. of unique reflections26 699 (2075)
Redundancy8.2 (8.1)
Completeness (%)93.2 (94)
R merge 0.191 (0.686)
7.8 (4.1)
Mosaicity (°)0.03–0.1
Structure refinement was carried out through multiple iterations of REFMAC (Murshudov et al., 2011 ▶), refining atomic coordinates and isotropic B factors. 2F o–F c and F o–F c electron density maps were generated after each refinement step, and further refinement was carried out by manual inspection using Coot (Emsley & Cowtan, 2004 ▶). In the refinement process, two disordered N-terminal residues were removed, as well as a bound sugar molecule present in the model but not in the crystal, and 124 water molecules were added. Final refinement gave R and R free values of 0.144 and 0.174, respectively. Complete processing statistics are given in Table 3 ▶. Fig. 5 ▶ shows the quality of the final refined structure.
Table 3

Refinement and model statistics for glucose isomerase

Values in parentheses refer to the highest resolution bin.

Resolution range (Å)49.7–2.09 (2.14–2.09)
Reflections used: working, total25 395, 26 685 (1879, 1974)
Completeness (%)92.4 (93.6)
R(working)/ 0.144/0.174 (0.186/0.227)
RMSD, bond lengths (Å)0.019
RMSD, bond angles (°)1.93
No. of protein/other atoms (non-H)3034/126
Mean B value, all atoms (Å2 17.6
Ramachandran statistics (%): favored, allowed, outliers97.13, 2.35, 0.52

R and are calculated using for the working and free-set reflections, respectively.

Figure 5

Part of the final refined structure showing the quality of the electron density map. The 2F o–F c map is shown in purple, contoured at 2σ, while the F o–F c map is shown in red (negative) and green (positive), contoured at 3σ.

Conclusion

Here, we present a technology that optimizes the kinetics of crystallization, eliminates crystal handling, eliminates cryoprotection and simplifies collection of diffraction data for structural biology. In this paper we developed processing methods for protein crystallization that follow the ideal kinetic pathway of slowly increasing supersaturation until a single crystal nucleates and then reducing supersaturation so that one crystal grows slowly to allow annealing of defects. Sample volume is not a thermodynamic variable in phase equilibrium, but since crystallization is a non-equilibrium process, volume plays a key role in determining the kinetics of crystallization. In Appendix A , we argue using a combination of simulation, theory and experiment that selecting the appropriate droplet diameter guarantees that only one crystal per drop will form when the drop volume . We identify the critical drop diameter for a particular crystallization condition in a single experiment by using a polydisperse emulsion with droplets ranging from a few micrometres to a few hundreds of micrometres in size. These polydisperse emulsions can be made with ease within seconds using only a pipette and a test tube. The probability of crystallization is proportional to the drop volume. As we use drops of order 1 nl, which are smaller drops than employed by other methods, the nucleation rates and supersaturation that we use are higher than usual. It remains to be seen how such high nucleation and growth rates impact crystal quality. In the future we will study the quality of protein crystal structure determination as a function of crystal size, nucleation rate and crystal growth rate to determine the optimal crystal size and crystallization conditions for serial crystallography. Employing these kinetic processing methods, we grew monodisperse crystals compartmentalized in emulsion droplets, with one crystal per drop. Monodisperse microfluidically produced drops of supersaturated protein solutions were stored on chip and slowly concentrated as water permeated through the thin-foil chip. One single crystal per drop was nucleated and grown on chip in identical conditions. While cyrocooled crystals can be stored almost indefinitely, the crystals grown and stored in our chips are stable for several weeks when the chips are stored in a water bath connected to an oil reservoir, which prevents evaporation and hence drying out. The chip for nucleating crystals was thin enough to be X-ray semi-transparent, and diffraction patterns were collected from these crystals on chip at room temperature. The structure of glucose isomerase was solved and refined at 2.09 Å resolution, to an / of 0.144/0.174, using merged diffraction data sets from 72 crystals of about 50 × 40 × 30 µm in size. Diffraction from room-temperature crystals stored on the chip in which they were nucleated and grown has many advantages over traditional off-chip cyroprotected crystals. On-chip diffraction means the crystals are not removed from their mother liquor, thus avoiding a process that can lead to dehydration and osmotic shock of the crystals and the generation of stress and strain. Room-temperature diffraction eliminates the laborious step of cryoprotection and has the additional effect of lowering the mosaicity, as cryoprotection generates stresses as a result of changing solvent conditions and temperature-induced volume changes. Our chip can be inexpensively mass produced and is simple to operate without the need for controlling valves. The long-term vision is to create a chip that uses temperature and concentration gradients to discover optimal crystal growth conditions (Shim et al., 2007 ▶). Next, crystals would be grown at the optimal conditions to create a stream of tiny crystals that would be serially conveyed to a part of the chip with ultra-thin windows for in situ diffraction. For this we are exploring windows made from materials such as ultra-thin silicon nitride (Weinhausen & Köster, 2013 ▶) or graphene (Wierman et al., 2013 ▶) and ways to reduce in-beam volumes of the fluids surrounding crystals.
  35 in total

Review 1.  Fabrication of microfluidic systems in poly(dimethylsiloxane).

Authors:  J C McDonald; D C Duffy; J R Anderson; D T Chiu; H Wu; O J Schueller; G M Whitesides
Journal:  Electrophoresis       Date:  2000-01       Impact factor: 3.535

2.  A method for generating single crystals that rely on internal fluid dynamics of microdroplets.

Authors:  Masatoshi Maeki; Hiroshi Yamaguchi; Kenichi Yamashita; Hiroyuki Nakamura; Masaya Miyazaki; Hideaki Maeda
Journal:  Chem Commun (Camb)       Date:  2012-04-12       Impact factor: 6.222

3.  Dropspots: a picoliter array in a microfluidic device.

Authors:  Christian H J Schmitz; Amy C Rowat; Sarah Köster; David A Weitz
Journal:  Lab Chip       Date:  2008-10-28       Impact factor: 6.799

4.  Immunological studies on egg white proteins. IV. Immunochemical and physical studies of lysozyme.

Authors:  L R WETTER; H F DEUTSCH
Journal:  J Biol Chem       Date:  1951-09       Impact factor: 5.157

5.  Using Microfluidics to Decouple Nucleation and Growth of Protein Crystals.

Authors:  Jung-Uk Shim; Galder Cristobal; Darren R Link; Todd Thorsen; Seth Fraden
Journal:  Cryst Growth Des       Date:  2007       Impact factor: 4.076

6.  Microfluidic devices for X-ray studies on hydrated cells.

Authors:  Britta Weinhausen; Sarah Köster
Journal:  Lab Chip       Date:  2012-12-03       Impact factor: 6.799

7.  Growth rates of protein crystals.

Authors:  Jeremy D Schmit; Ken Dill
Journal:  J Am Chem Soc       Date:  2012-02-23       Impact factor: 15.419

8.  Biocompatible surfactants for water-in-fluorocarbon emulsions.

Authors:  C Holtze; A C Rowat; J J Agresti; J B Hutchison; F E Angilè; C H J Schmitz; S Köster; H Duan; K J Humphry; R A Scanga; J S Johnson; D Pisignano; D A Weitz
Journal:  Lab Chip       Date:  2008-09-02       Impact factor: 6.799

9.  Radiation damage in macromolecular crystallography: what is it and why should we care?

Authors:  Elspeth F Garman
Journal:  Acta Crystallogr D Biol Crystallogr       Date:  2010-03-24

10.  An introduction to data reduction: space-group determination, scaling and intensity statistics.

Authors:  Philip R Evans
Journal:  Acta Crystallogr D Biol Crystallogr       Date:  2011-03-18
View more
  36 in total

1.  In situ X-ray data collection and structure phasing of protein crystals at Structural Biology Center 19-ID.

Authors:  Karolina Michalska; Kemin Tan; Changsoo Chang; Hui Li; Catherine Hatzos-Skintges; Michael Molitsky; Randy Alkire; Andrzej Joachimiak
Journal:  J Synchrotron Radiat       Date:  2015-10-15       Impact factor: 2.616

2.  In situ serial Laue diffraction on a microfluidic crystallization device.

Authors:  Sarah L Perry; Sudipto Guha; Ashtamurthy S Pawate; Robert Henning; Irina Kosheleva; Vukica Srajer; Paul J A Kenis; Zhong Ren
Journal:  J Appl Crystallogr       Date:  2014-11-18       Impact factor: 3.304

3.  Towards time-resolved serial crystallography in a microfluidic device.

Authors:  Ashtamurthy S Pawate; Vukica Šrajer; Jeremy Schieferstein; Sudipto Guha; Robert Henning; Irina Kosheleva; Marius Schmidt; Zhong Ren; Paul J A Kenis; Sarah L Perry
Journal:  Acta Crystallogr F Struct Biol Commun       Date:  2015-06-27       Impact factor: 1.056

4.  Dynamic Structural Biology Experiments at XFEL or Synchrotron Sources.

Authors:  Pierre Aller; Allen M Orville
Journal:  Methods Mol Biol       Date:  2021

5.  Graphene-based microfluidics for serial crystallography.

Authors:  Shuo Sui; Yuxi Wang; Kristopher W Kolewe; Vukica Srajer; Robert Henning; Jessica D Schiffman; Christos Dimitrakopoulos; Sarah L Perry
Journal:  Lab Chip       Date:  2016-08-02       Impact factor: 6.799

6.  Crystallization via tubing microfluidics permits both in situ and ex situ X-ray diffraction.

Authors:  Charline J J Gerard; Gilles Ferry; Laurent M Vuillard; Jean A Boutin; Leonard M G Chavas; Tiphaine Huet; Nathalie Ferte; Romain Grossier; Nadine Candoni; Stéphane Veesler
Journal:  Acta Crystallogr F Struct Biol Commun       Date:  2017-10-02       Impact factor: 1.056

7.  High-throughput in situ X-ray screening of and data collection from protein crystals at room temperature and under cryogenic conditions.

Authors:  Jana Broecker; Takefumi Morizumi; Wei-Lin Ou; Viviane Klingel; Anling Kuo; David J Kissick; Andrii Ishchenko; Ming-Yue Lee; Shenglan Xu; Oleg Makarov; Vadim Cherezov; Craig M Ogata; Oliver P Ernst
Journal:  Nat Protoc       Date:  2018-01-04       Impact factor: 13.491

8.  3D printed droplet generation devices for serial femtosecond crystallography enabled by surface coating.

Authors:  Austin Echelmeier; Daihyun Kim; Jorvani Cruz Villarreal; Jesse Coe; Sebastian Quintana; Gerrit Brehm; Ana Egatz-Gomez; Reza Nazari; Raymond G Sierra; Jason E Koglin; Alexander Batyuk; Mark S Hunter; Sébastien Boutet; Nadia Zatsepin; Richard A Kirian; Thomas D Grant; Petra Fromme; Alexandra Ros
Journal:  J Appl Crystallogr       Date:  2019-08-29       Impact factor: 3.304

Review 9.  Current advances in synchrotron radiation instrumentation for MX experiments.

Authors:  Robin L Owen; Jordi Juanhuix; Martin Fuchs
Journal:  Arch Biochem Biophys       Date:  2016-04-01       Impact factor: 4.013

Review 10.  Multiple Modes of Protein-Protein Interactions Promote RNP Granule Assembly.

Authors:  Tanja Mittag; Roy Parker
Journal:  J Mol Biol       Date:  2018-08-09       Impact factor: 5.469

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.