Literature DB >> 24506654

Comparison of patient specific dose metrics between chest radiography, tomosynthesis, and CT for adult patients of wide ranging body habitus.

Yakun Zhang1, Xiang Li2, W Paul Segars3, Ehsan Samei4.   

Abstract

PURPOSE: Given the radiation concerns inherent to the x-ray modalities, accurately estimating the radiation doses that patients receive during different imaging modalities is crucial. This study estimated organ doses, effective doses, and risk indices for the three clinical chest x-ray imaging techniques (chest radiography, tomosynthesis, and CT) using 59 anatomically variable voxelized phantoms and Monte Carlo simulation methods.
METHODS: A total of 59 computational anthropomorphic male and female extended cardiac-torso (XCAT) adult phantoms were used in this study. Organ doses and effective doses were estimated for a clinical radiography system with the capability of conducting chest radiography and tomosynthesis (Definium 8000, VolumeRAD, GE Healthcare) and a clinical CT system (LightSpeed VCT, GE Healthcare). A Monte Carlo dose simulation program (PENELOPE, version 2006, Universitat de Barcelona, Spain) was used to mimic these two clinical systems. The Duke University (Durham, NC) technique charts were used to determine the clinical techniques for the radiographic modalities. An exponential relationship between CTDIvol and patient diameter was used to determine the absolute dose values for CT. The simulations of the two clinical systems compute organ and tissue doses, which were then used to calculate effective dose and risk index. The calculation of the two dose metrics used the tissue weighting factors from ICRP Publication 103 and BEIR VII report.
RESULTS: The average effective dose of the chest posteroanterior examination was found to be 0.04 mSv, which was 1.3% that of the chest CT examination. The average effective dose of the chest tomosynthesis examination was found to be about ten times that of the chest posteroanterior examination and about 12% that of the chest CT examination. With increasing patient average chest diameter, both the effective dose and risk index for CT increased considerably in an exponential fashion, while these two dose metrics only increased slightly for radiographic modalities and for chest tomosynthesis. Effective and organ doses normalized to mAs all illustrated an exponential decrease with increasing patient size. As a surface organ, breast doses had less correlation with body size than that of lungs or liver.
CONCLUSIONS: Patient body size has a much greater impact on radiation dose of chest CT examinations than chest radiography and tomosynthesis. The size of a patient should be considered when choosing the best thoracic imaging modality.

Entities:  

Mesh:

Year:  2014        PMID: 24506654      PMCID: PMC3985882          DOI: 10.1118/1.4859315

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  28 in total

1.  Organ weight in 684 adult autopsies: new tables for a Caucasoid population.

Authors:  G L de la Grandmaison; I Clairand; M Durigon
Journal:  Forensic Sci Int       Date:  2001-06-15       Impact factor: 2.395

2.  An experimental comparison of detector performance for computed radiography systems.

Authors:  Ehsan Samei; Michael J Flynn
Journal:  Med Phys       Date:  2002-04       Impact factor: 4.071

Review 3.  Recent advances in chest radiography.

Authors:  H Page McAdams; Ehsan Samei; James Dobbins; Georgia D Tourassi; Carl E Ravin
Journal:  Radiology       Date:  2006-12       Impact factor: 11.105

4.  Radiation doses and detriment from chest x-ray examinations.

Authors:  W Huda; G A Sandison; R F Palser; D Savoie
Journal:  Phys Med Biol       Date:  1989-10       Impact factor: 3.609

Review 5.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

6.  Influence of phantom diameter, kVp and scan mode upon computed tomography dose index.

Authors:  Edward L Nickoloff; Ajoy K Dutta; Zheng F Lu
Journal:  Med Phys       Date:  2003-03       Impact factor: 4.071

7.  Comparison of radiation doses to patients undergoing standard radiographic examinations with conventional screen-film radiography, computed radiography and direct digital radiography.

Authors:  G Compagnone; M Casadio Baleni; L Pagan; F L Calzolaio; L Barozzi; C Bergamini
Journal:  Br J Radiol       Date:  2006-11       Impact factor: 3.039

8.  Effective doses to patients undergoing thoracic computed tomography examinations.

Authors:  W Huda; E M Scalzetti; M Roskopf
Journal:  Med Phys       Date:  2000-05       Impact factor: 4.071

9.  Effective dose and energy imparted in diagnostic radiology.

Authors:  W Huda; N A Gkanatsios
Journal:  Med Phys       Date:  1997-08       Impact factor: 4.071

10.  An approach for the estimation of effective radiation dose at CT in pediatric patients.

Authors:  W Huda; J V Atherton; D E Ware; W A Cumming
Journal:  Radiology       Date:  1997-05       Impact factor: 11.105

View more
  10 in total

1.  Advances in Computational Human Phantoms and Their Applications in Biomedical Engineering - A Topical Review.

Authors:  Wolfgang Kainz; Esra Neufeld; Wesley E Bolch; Christian G Graff; Chan Hyeong Kim; Niels Kuster; Bryn Lloyd; Tina Morrison; Paul Segars; Yeon Soo Yeom; Maria Zankl; X George Xu; Benjamin M W Tsui
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-01

2.  Organ dose variability and trends in tomosynthesis and radiography.

Authors:  Jocelyn Hoye; Yakun Zhang; Greeshma Agasthya; Greg Sturgeon; Anuj Kapadia; W Paul Segars; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2017-08-01

3.  Application of a pixel-shifted linear interpolation technique for reducing the projection number in tomosynthesis imaging.

Authors:  Ryohei Fukui; Junji Shiraishi
Journal:  Radiol Phys Technol       Date:  2018-11-19

Review 4.  Application of the 4-D XCAT Phantoms in Biomedical Imaging and Beyond.

Authors:  W Paul Segars; B M W Tsui; George S K Fung; Ehsan Samei
Journal:  IEEE Trans Med Imaging       Date:  2017-08-10       Impact factor: 10.048

5.  A GPU-accelerated framework for individualized estimation of organ doses in digital tomosynthesis.

Authors:  Shobhit Sharma; Anuj Kapadia; Justin Brown; William Paul Segars; Wesley Bolch; Ehsan Samei
Journal:  Med Phys       Date:  2021-12-22       Impact factor: 4.071

6.  Dose coefficients for organ dosimetry in tomosynthesis imaging of adults and pediatrics across diverse protocols.

Authors:  Shobhit Sharma; Anuj Kapadia; Francesco Ria; W Paul Segars; Ehsan Samei
Journal:  Med Phys       Date:  2022-06-21       Impact factor: 4.506

7.  The relationship of whole human vertebral body creep to bone density and texture via clinically available imaging modalities.

Authors:  Daniel Oravec; Woong Kim; Michael J Flynn; Yener N Yeni
Journal:  J Biomech       Date:  2022-02-24       Impact factor: 2.789

8.  Assessment of Intravertebral Mechanical Strains and Cancellous Bone Texture Under Load Using a Clinically Available Digital Tomosynthesis Modality.

Authors:  Daniel Oravec; Joshua Drost; Roger Zauel; Michael J Flynn; Yener N Yeni
Journal:  J Biomech Eng       Date:  2021-10-01       Impact factor: 1.899

Review 9.  Progress and prospects of early detection in lung cancer.

Authors:  Sean Blandin Knight; Phil A Crosbie; Haval Balata; Jakub Chudziak; Tracy Hussell; Caroline Dive
Journal:  Open Biol       Date:  2017-09       Impact factor: 6.411

10.  Construction of an Anthropomorphic Phantom for Use in Evaluating Pediatric Airway Digital Tomosynthesis Protocols.

Authors:  Nima Kasraie; Amie Robinson; Sherwin Chan
Journal:  Radiol Res Pract       Date:  2018-04-18
  10 in total