Literature DB >> 12674240

Influence of phantom diameter, kVp and scan mode upon computed tomography dose index.

Edward L Nickoloff1, Ajoy K Dutta, Zheng F Lu.   

Abstract

The computed tomography (CT) radiation dose to pediatric patients has received considerable attention recently. Moreover, it is important to be able to determine CT radiation doses for various patient sizes ranging from infants to large adults. The current AAPM protocol only measures CT radiation dose using a 16 cm acrylic phantom to represent an adult head and a 32 cm acrylic phantom to represent an adult body. The goal of this paper is to study the dependence of the computed tomography dose index (CTDI) upon the size of the phantom, the kVp selected and the scan mode employed. Our measurements were done on phantom sizes ranging from 6 cm to 32 cm. The x-ray tube potential ranged from 80 to 140 kVp. The scan modes utilized for the measurements included: consecutive axial scans, single-slice helical scans with variable pitch and multislice helical scans with variable pitch. The results were consolidated into simplified equations which related the phantom diameter and kVp to the measured CTDI. Some generalizations were made about the relationship between the scan modes of the various CT units to the measured radiation doses. The CTDI appears to be an exponential function of phantom diameter. For the same kVp and mAs, the radiation doses for smaller phantoms are much greater than for larger sizes. The derived relationship can be used to estimate the radiation doses for a variety of scan conditions and modes from measurements with the two standard reference phantoms. A method was also given for converting axial CT dose measurements to appropriate MSAD values for helical CT scans.

Entities:  

Mesh:

Year:  2003        PMID: 12674240     DOI: 10.1118/1.1543149

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  23 in total

1.  A computer-simulated liver phantom (virtual liver phantom) for multidetector computed tomography evaluation.

Authors:  Yoshinori Funama; Kazuo Awai; Osamu Miyazaki; Yoshiharu Nakayama; Da Liu; Taiga Goto; Yasuyuki Yamashita; Shinichi Hori
Journal:  Eur Radiol       Date:  2005-10-20       Impact factor: 5.315

2.  Is PET/CT necessary in paediatric oncology? For.

Authors:  Christiane Franzius; Kai Uwe Juergens; Otmar Schober
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-08       Impact factor: 9.236

3.  Converting dose-length product to effective dose at CT.

Authors:  Walter Huda; Kent M Ogden; Mohammad R Khorasani
Journal:  Radiology       Date:  2008-09       Impact factor: 11.105

Review 4.  Anniversary paper. Development of x-ray computed tomography: the role of medical physics and AAPM from the 1970s to present.

Authors:  Xiaochuan Pan; Jeffrey Siewerdsen; Patrick J La Riviere; Willi A Kalender
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

5.  Patient-based estimation of organ dose for a population of 58 adult patients across 13 protocol categories.

Authors:  Pooyan Sahbaee; W Paul Segars; Ehsan Samei
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

Review 6.  Radiation dose in non-dental cone beam CT applications: a systematic review.

Authors:  Cosimo Nardi; Sergio Salerno; Roberto Molteni; Mariaelena Occhipinti; Giulia Grazzini; Niccolò Norberti; Cesare Cordopatri; Stefano Colagrande
Journal:  Radiol Med       Date:  2018-06-05       Impact factor: 3.469

7.  Comparison of patient specific dose metrics between chest radiography, tomosynthesis, and CT for adult patients of wide ranging body habitus.

Authors:  Yakun Zhang; Xiang Li; W Paul Segars; Ehsan Samei
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

8.  Lateral decubitus positioning for cervical nerve root block using CT image guidance minimizes effective radiation dose and procedural time.

Authors:  T S Miller; K Fruauff; J Farinhas; D Pasquale; C Romano; A H Schoenfeld; A Brook
Journal:  AJNR Am J Neuroradiol       Date:  2012-06-28       Impact factor: 3.825

9.  Patient-specific dose estimation for pediatric chest CT.

Authors:  Xiang Li; Ehsan Samei; W Paul Segars; Gregory M Sturgeon; James G Colsher; Donald P Frush
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

10.  Radiation doses to children with shunt-treated hydrocephalus.

Authors:  Lise Jofrid Holmedal; Eva Godske Friberg; Ingelin Børretzen; Hilde Olerud; Liv Laegreid; Karen Rosendahl
Journal:  Pediatr Radiol       Date:  2007-10-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.