Literature DB >> 17065288

Comparison of radiation doses to patients undergoing standard radiographic examinations with conventional screen-film radiography, computed radiography and direct digital radiography.

G Compagnone1, M Casadio Baleni, L Pagan, F L Calzolaio, L Barozzi, C Bergamini.   

Abstract

New flat-panel direct digital radiography equipment has recently been installed in our Accident and Emergency Department; its characteristics and versatility are well suited to the work undertaken in this environment. The aim of this study was to compare radiation doses to patients undergoing standard radiographic examinations using conventional screen-film radiography, computed radiography and direct digital radiography; entrance surface dose and effective dose were calculated for six standard examinations (a total of 10 projections) using standard patient exposure parameters for the three imaging modalities. It was found that doses for computed radiography (all examinations) were higher than the doses for the other two modalities; effective doses for direct digital radiography were approximately 29% and approximately 43% lower than those for screen-film radiography and computed radiography, respectively. The image quality met the criteria in the European guidelines for all modalities.

Entities:  

Mesh:

Year:  2006        PMID: 17065288     DOI: 10.1259/bjr/57138583

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  6 in total

1.  Assessment of patient doses in CR examinations throughout a large health region.

Authors:  Yogesh Thakur; Thorarin A Bjarnason; Kevin Hammerstrom; Lorie Marchinkow; Tim Koch; John E Aldrich
Journal:  J Digit Imaging       Date:  2012-02       Impact factor: 4.056

2.  First test on three stitching methods with digital detectors used in radiography.

Authors:  Sarah Bassi; Stefano Baldini; Ciro Rebuffat; Riccardo Sarti; Fabio Ferretti
Journal:  Radiol Phys Technol       Date:  2012-11-10

3.  Optimisation of radiological protocols for chest imaging using computed radiography and flat-panel X-ray detectors.

Authors:  G Compagnone; M Casadio Baleni; E Di Nicola; M Valentino; M Benati; L F Calzolaio; N Oberhofer; E Fabbri; S Domenichelli; L Barozzi
Journal:  Radiol Med       Date:  2012-10-22       Impact factor: 3.469

4.  Comparison of patient specific dose metrics between chest radiography, tomosynthesis, and CT for adult patients of wide ranging body habitus.

Authors:  Yakun Zhang; Xiang Li; W Paul Segars; Ehsan Samei
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

5.  Digital X-ray: Not so indefectible!

Authors:  Aanchal Dixit; Sandeep Sharan
Journal:  Ann Card Anaesth       Date:  2019 Jul-Sep

Review 6.  Patient-based radiographic exposure factor selection: a systematic review.

Authors:  William Ching; John Robinson; Mark McEntee
Journal:  J Med Radiat Sci       Date:  2014-08-07
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.