Literature DB >> 10841385

Effective doses to patients undergoing thoracic computed tomography examinations.

W Huda1, E M Scalzetti, M Roskopf.   

Abstract

The purpose of this study was to investigate how x-ray technique factors and effective doses vary with patient size in chest CT examinations. Technique factors (kVp, mAs, section thickness, and number of sections) were recorded for 44 patients who underwent a routine chest CT examination. Patient weights were recorded together with dimensions and mean Hounsfield unit values obtained from representative axial CT images. The total mass of directly irradiated patient was modeled as a cylinder of water to permit the computation of the mean patient dose and total energy imparted for each chest CT examination. Computed values of energy imparted during the chest CT examination were converted into effective doses taking into account the patient weight. Patient weights ranged from 4.5 to 127 kg, and half the patients in this study were children under 18 years of age. All scans were performed at 120 kVp with a 1 s scan time. The selected tube current showed no correlation with patient weight (r2=0.06), indicating that chest CT examination protocols do not take into account for the size of the patient. Energy imparted increased with increasing patient weight, with values of energy imparted for 10 and 70 kg patients being 85 and 310 mJ, respectively. The effective dose showed an inverse correlation with increasing patient weight, however, with values of effective dose for 10 and 70 kg patients being 9.6 and 5.4 mSv, respectively. Current CT technique factors (kVp/mAs) used to perform chest CT examinations result in relatively high patient doses, which could be reduced by adjusting technique factors based on patient size.

Entities:  

Mesh:

Year:  2000        PMID: 10841385     DOI: 10.1118/1.598949

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  32 in total

1.  Strategies of dose reduction.

Authors:  Donald P Frush
Journal:  Pediatr Radiol       Date:  2002-03-07

2.  Effective doses to adult and pediatric patients.

Authors:  Walter Huda
Journal:  Pediatr Radiol       Date:  2002-03-06

3.  In-patient to isocenter KERMA ratios in CT.

Authors:  Walter Huda; Kent M Ogden; Robert L Lavallee; Marsha L Roskopf; Ernest M Scalzetti
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

4.  Radiation dose to organs and tissues from mammography: Monte Carlo and phantom study.

Authors:  Ioannis Sechopoulos; Sankararaman Suryanarayanan; Srinivasan Vedantham; Carl J D'Orsi; Andrew Karellas
Journal:  Radiology       Date:  2007-12-04       Impact factor: 11.105

5.  Monte Carlo and phantom study of the radiation dose to the body from dedicated CT of the breast.

Authors:  Ioannis Sechopoulos; Srinivasan Vedantham; Sankararaman Suryanarayanan; Carl J D'Orsi; Andrew Karellas
Journal:  Radiology       Date:  2008-02-21       Impact factor: 11.105

Review 6.  Anniversary paper. Development of x-ray computed tomography: the role of medical physics and AAPM from the 1970s to present.

Authors:  Xiaochuan Pan; Jeffrey Siewerdsen; Patrick J La Riviere; Willi A Kalender
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

7.  Improvement of image quality of multislice spiral CT scans of the head and neck region using a raw data-based multidimensional adaptive filtering (MAF) technique.

Authors:  Ulrich Baum; Katharina Anders; Gregor Steinbichler; Michael Lell; Holger Greess; Thomas Riedel; Marc Kachelriess; Willi A Kalender; Werner A Bautz
Journal:  Eur Radiol       Date:  2004-08-24       Impact factor: 5.315

8.  Scan time and patient dose for thoracic imaging in neonates and small children using axial volumetric 320-detector row CT compared to helical 64-, 32-, and 16- detector row CT acquisitions.

Authors:  Lucia J M Kroft; Joost J H Roelofs; Jacob Geleijns
Journal:  Pediatr Radiol       Date:  2009-12-08

9.  Radiation doses during chest examinations using dose modulation techniques in multislice CT scanner.

Authors:  Roshan S Livingstone; Joe Pradip; Paul M Dinakran; B Srikanth
Journal:  Indian J Radiol Imaging       Date:  2010-05

Review 10.  Radiation exposure from chest CT: issues and strategies.

Authors:  Mannudeep K Kalra; Michael M Maher; Stefania Rizzo; David Kanarek; Jo-Anne O Shepard; Jo-Anne O Shephard
Journal:  J Korean Med Sci       Date:  2004-04       Impact factor: 2.153

View more