Literature DB >> 24007181

A visual-search model observer for multislice-multiview SPECT images.

Howard C Gifford1.   

Abstract

PURPOSE: Mathematical model observers are intended for efficient assessment of diagnostic image quality, but model-observer studies often are not representative of clinical realities. Model observers based on a visual-search (VS) paradigm may allow for greater clinical relevance. The author has compared the performances of several VS model observers with those of human observers and an existing scanning model observer for a study involving nodule detection and localization in simulated Tc-99m single-photon emission computed tomography (SPECT) lung volumes.
METHODS: A localization receiver operating characteristic (LROC) study compared two iterative SPECT reconstruction strategies: an all-corrections (AllC) strategy with compensations for attenuation, scatter, and distance-dependent camera resolution and an "RC" strategy with resolution compensation only. Nodules in the simulation phantom were of three different relative contrasts. Observers in the study had access to the coronal, sagittal, and transverse displays of the reconstructed volumes. Three human observers each read 50 training volumes and 100 test volumes per reconstruction strategy. The same images were analyzed by a channelized nonprewhitening (CNPW) scanning observer and two VS observers. The VS observers implemented holistic search processes that identified focal points of Tc-99m uptake for subsequent analysis by the CNPW scanning model. The level of prior knowledge about the background structure in the images was a study variable for the model observers. Performance was scored by area under the LROC curve.
RESULTS: The average human-observer performances were respectively 0.67 ± 0.04 and 0.61 ± 0.03 for the RC and AllC strategies. Given approximate knowledge about the background structure, both VS models scored 0.69 ± 0.08 (RC) and 0.66 ± 0.08 (AllC). The scanning observer reversed the strategy ranking in scoring 0.73 ± 0.08 with the AllC strategy and 0.64 ± 0.08 with the RC strategy. The VS observers exhibited less sensitivity to variations in background knowledge compared to the scanning observer.
CONCLUSIONS: The VS framework has the potential to increase the clinical similitude of model-observer studies and to enhance the ability of existing model observers to quantitatively predict human-observer performance.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24007181      PMCID: PMC3772942          DOI: 10.1118/1.4818824

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  14 in total

1.  A dual-photopeak window method for scatter correction.

Authors:  M A King; G J Hademenos; S J Glick
Journal:  J Nucl Med       Date:  1992-04       Impact factor: 10.057

2.  Evaluation of internal noise methods for Hotelling observer models.

Authors:  Yani Zhang; Binh T Pham; Miguel P Eckstein
Journal:  Med Phys       Date:  2007-08       Impact factor: 4.071

3.  Channelized Hotelling observers for the assessment of volumetric imaging data sets.

Authors:  Ljiljana Platiša; Bart Goossens; Ewout Vansteenkiste; Subok Park; Brandon D Gallas; Aldo Badano; Wilfried Philips
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2011-06-01       Impact factor: 2.129

Review 4.  Unified measurement of observer performance in detecting and localizing target objects on images.

Authors:  R G Swensson
Journal:  Med Phys       Date:  1996-10       Impact factor: 4.071

5.  A Monte Carlo program for the simulation of scintillation camera characteristics.

Authors:  M Ljungberg; S E Strand
Journal:  Comput Methods Programs Biomed       Date:  1989-08       Impact factor: 5.428

6.  Addition of a channel mechanism to the ideal-observer model.

Authors:  K J Myers; H H Barrett
Journal:  J Opt Soc Am A       Date:  1987-12       Impact factor: 2.129

7.  Human- and model-observer performance in ramp-spectrum noise: effects of regularization and object variability.

Authors:  C K Abbey; H H Barrett
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2001-03       Impact factor: 2.129

8.  A random-sum Wilcoxon statistic and its application to analysis of ROC and LROC data.

Authors:  Liansheng Larry Tang; N Balakrishnan
Journal:  J Stat Plan Inference       Date:  2010-06-12       Impact factor: 1.111

9.  The utility of a somatostatin-type receptor binding peptide radiopharmaceutical (P829) in the evaluation of solitary pulmonary nodules.

Authors:  J E Blum; H Handmaker; N A Rinne
Journal:  Chest       Date:  1999-01       Impact factor: 9.410

10.  A Multiclass Model Observer for Multislice-Multiview Images.

Authors:  H C Gifford; A Lehovich; M A King
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2006
View more
  15 in total

1.  The role of extra-foveal processing in 3D imaging.

Authors:  Miguel P Eckstein; Miguel A Lago; Craig K Abbey
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-10

2.  Foveated Model Observers to predict human performance in 3D images.

Authors:  Miguel A Lago; Craig K Abbey; Miguel P Eckstein
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-10

3.  Deep-learning-based model observer for a lung nodule detection task in computed tomography.

Authors:  Hao Gong; Qiyuan Hu; Andrew Walther; Chi Wan Koo; Edwin A Takahashi; David L Levin; Tucker F Johnson; Megan J Hora; Shuai Leng; Joel G Fletcher; Cynthia H McCollough; Lifeng Yu
Journal:  J Med Imaging (Bellingham)       Date:  2020-06-30

4.  Task Equivalence for Model and Human-Observer Comparisons in SPECT Localization Studies.

Authors:  Anando Sen; Faraz Kalantari; Howard C Gifford
Journal:  IEEE Trans Nucl Sci       Date:  2016-05-19       Impact factor: 1.679

5.  Collimator optimization in myocardial perfusion SPECT using the ideal observer and realistic background variability for lesion detection and joint detection and localization tasks.

Authors:  Michael Ghaly; Yong Du; Jonathan M Links; Eric C Frey
Journal:  Phys Med Biol       Date:  2016-02-19       Impact factor: 3.609

6.  Interactions of lesion detectability and size across single-slice DBT and 3D DBT.

Authors:  Miguel A Lago; Craig K Abbey; Bruno Barufaldi; Predrag R Bakic; Susan P Weinstein; Andrew D Maidment; Miguel P Eckstein
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-07

7.  Evaluation of Search Strategies for Microcalcifications and Masses in 3D Images.

Authors:  Miguel P Eckstein; Miguel A Lago; Craig K Abbey
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-07

8.  Visual-search observers for assessing tomographic x-ray image quality.

Authors:  Howard C Gifford; Zhihua Liang; Mini Das
Journal:  Med Phys       Date:  2016-03       Impact factor: 4.071

9.  Accounting for anatomical noise in search-capable model observers for planar nuclear imaging.

Authors:  Anando Sen; Howard C Gifford
Journal:  J Med Imaging (Bellingham)       Date:  2016-01-26

10.  Efficient visual-search model observers for PET.

Authors:  H C Gifford
Journal:  Br J Radiol       Date:  2014-05-16       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.