Literature DB >> 1552349

A dual-photopeak window method for scatter correction.

M A King1, G J Hademenos, S J Glick.   

Abstract

The imaging of scattered photons degrades contrast and is a major source of error in the quantitation of activity. It was hypothesized that, if the photopeak was divided into two nonoverlapping energy windows, a regression relation could be obtained between the ratio of counts within these windows and the scatter fraction for counts within the total region. This idea was tested by acquiring dual photopeak window acquisitions of a 99mTc point source in an elliptical attenuator, and at the same locations in air. From these, a regression between the scatter fraction and window ratio was determined. When this regression was applied to estimate the scatter distribution for acquisitions in both uniform and nonuniform elliptical attenuators, the residual scatter fraction was reduced approximately ten-fold and the estimated scatter line spread functions matched very closely the tails of the total line spread functions. In SPECT acquisitions, dual-photopeak window scatter correction was observed to significantly increase the contrast of "cold" spheres, improve the accuracy of estimating activity at the center of "hot" spheres, and return the three-dimensional modulation transfer function for point sources in an elliptical attenuator to near their in-air shape.

Mesh:

Year:  1992        PMID: 1552349

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  29 in total

Review 1.  Scatter modelling and compensation in emission tomography.

Authors:  Habib Zaidi; Kenneth F Koral
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-31       Impact factor: 9.236

2.  Accelerated SPECT Monte Carlo Simulation Using Multiple Projection Sampling and Convolution-Based Forced Detection.

Authors:  Shaoying Liu; Michael A King; Aaron B Brill; Michael G Stabin; Troy H Farncombe
Journal:  IEEE Trans Nucl Sci       Date:  2008-01-01       Impact factor: 1.679

3.  Effects of shortened acquisition time on accuracy and precision of quantitative estimates of organ activity.

Authors:  Bin He; Eric C Frey
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

4.  Rapid Optimization of SPECT Scatter Correction Using Model LROC Observers.

Authors:  Santosh Kulkarni; Parmeshwar Khurd; Lili Zhou; Gene Gindi
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2007

5.  Characterization of simulated incident scatter and the impact on quantification in dedicated breast single-photon emission computed tomography.

Authors:  Steve D Mann; Martin P Tornai
Journal:  J Med Imaging (Bellingham)       Date:  2015-09-21

6.  Development of a practical image-based scatter correction method for brain perfusion SPECT: comparison with the TEW method.

Authors:  Miho Shidahara; Hiroshi Watabe; Kyeong Min Kim; Takashi Kato; Shoji Kawatsu; Rikio Kato; Kumiko Yoshimura; Hidehiro Iida; Kengo Ito
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-05-28       Impact factor: 9.236

7.  Speedup OS-EM Image Reconstruction by PC Graphics Card Technologies for Quantitative SPECT with Varying Focal-Length Fan-Beam Collimation.

Authors:  Zigang Wang; Guoping Han; Tianfang Li; Zhengrong Liang
Journal:  IEEE Trans Nucl Sci       Date:  2005-10       Impact factor: 1.679

8.  Improved quantification in single-pinhole and multiple-pinhole SPECT using micro-CT information.

Authors:  Christian Vanhove; Michel Defrise; Axel Bossuyt; Tony Lahoutte
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-02-14       Impact factor: 9.236

9.  A visual-search model observer for multislice-multiview SPECT images.

Authors:  Howard C Gifford
Journal:  Med Phys       Date:  2013-09       Impact factor: 4.071

10.  A postprocessing method for compensation of scatter and collimator blurring in SPECT: a proof-of-concept study.

Authors:  Yan Yan; Gengsheng Lawrence Zeng
Journal:  J Nucl Med Technol       Date:  2009-05-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.