Literature DB >> 22639485

A random-sum Wilcoxon statistic and its application to analysis of ROC and LROC data.

Liansheng Larry Tang1, N Balakrishnan.   

Abstract

The Wilcoxon-Mann-Whitney statistic is commonly used for a distribution-free comparison of two groups. One requirement for its use is that the sample sizes of the two groups are fixed. This is violated in some of the applications such as medical imaging studies and diagnostic marker studies; in the former, the violation occurs since the number of correctly localized abnormal images is random, while in the latter the violation is due to some subjects not having observable measurements. For this reason, we propose here a random-sum Wilcoxon statistic for comparing two groups in the presence of ties, and derive its variance as well as its asymptotic distribution for large sample sizes. The proposed statistic includes the regular Wilcoxon rank-sum statistic. Finally, we apply the proposed statistic for summarizing location response operating characteristic data from a liver computed tomography study, and also for summarizing diagnostic accuracy of biomarker data.

Entities:  

Year:  2010        PMID: 22639485      PMCID: PMC3358783          DOI: 10.1016/j.jspi.2010.06.011

Source DB:  PubMed          Journal:  J Stat Plan Inference        ISSN: 0378-3758            Impact factor:   1.111


  12 in total

1.  Visual detection and localization of radiographic images.

Authors:  S J Starr; C E Metz; L B Lusted; D J Goodenough
Journal:  Radiology       Date:  1975-09       Impact factor: 11.105

2.  Visualization and detection-localization on computed tomographic images.

Authors:  S E Seltzer; R G Swensson; R D Nawfel; J F Lentini; I Kazda; P F Judy
Journal:  Invest Radiol       Date:  1991-04       Impact factor: 6.016

3.  ROC analysis for markers with mass at zero.

Authors:  Enrique F Schisterman; Benjamin Reiser; David Faraggi
Journal:  Stat Med       Date:  2006-02-28       Impact factor: 2.373

4.  Receiver operating characteristic curve inference from a sample with a limit of detection.

Authors:  Neil J Perkins; Enrique F Schisterman; Albert Vexler
Journal:  Am J Epidemiol       Date:  2006-11-16       Impact factor: 4.897

5.  On the Asymptotic Distribution of the Sum of a Random Number of Random Variables.

Authors:  H Robbins
Journal:  Proc Natl Acad Sci U S A       Date:  1948-04       Impact factor: 11.205

6.  High-performance wavelet compression for mammography: localization response operating characteristic evaluation.

Authors:  Maria Kallergi; Bradley J Lucier; Claudia G Berman; Marla R Hersh; Jihai J Kim; Margaret S Szabunio; Robert A Clark
Journal:  Radiology       Date:  2006-01       Impact factor: 11.105

7.  Maximum likelihood analysis of free-response receiver operating characteristic (FROC) data.

Authors:  D P Chakraborty
Journal:  Med Phys       Date:  1989 Jul-Aug       Impact factor: 4.071

8.  The meaning and use of the area under a receiver operating characteristic (ROC) curve.

Authors:  J A Hanley; B J McNeil
Journal:  Radiology       Date:  1982-04       Impact factor: 11.105

9.  Receiver operator characteristic (ROC) curves and non-normal data: an empirical study.

Authors:  M J Goddard; I Hinberg
Journal:  Stat Med       Date:  1990-03       Impact factor: 2.373

10.  Maximum likelihood ratio tests for comparing the discriminatory ability of biomarkers subject to limit of detection.

Authors:  Albert Vexler; Aiyi Liu; Ekaterina Eliseeva; Enrique F Schisterman
Journal:  Biometrics       Date:  2007-11-19       Impact factor: 1.701

View more
  7 in total

1.  A nonparametric procedure for comparing the areas under correlated LROC curves.

Authors:  Adam Wunderlich; Frédéric Noo
Journal:  IEEE Trans Med Imaging       Date:  2012-06-18       Impact factor: 10.048

2.  A visual-search model observer for multislice-multiview SPECT images.

Authors:  Howard C Gifford
Journal:  Med Phys       Date:  2013-09       Impact factor: 4.071

3.  Task Equivalence for Model and Human-Observer Comparisons in SPECT Localization Studies.

Authors:  Anando Sen; Faraz Kalantari; Howard C Gifford
Journal:  IEEE Trans Nucl Sci       Date:  2016-05-19       Impact factor: 1.679

4.  Visual-search observers for assessing tomographic x-ray image quality.

Authors:  Howard C Gifford; Zhihua Liang; Mini Das
Journal:  Med Phys       Date:  2016-03       Impact factor: 4.071

5.  Accounting for anatomical noise in search-capable model observers for planar nuclear imaging.

Authors:  Anando Sen; Howard C Gifford
Journal:  J Med Imaging (Bellingham)       Date:  2016-01-26

6.  Efficient visual-search model observers for PET.

Authors:  H C Gifford
Journal:  Br J Radiol       Date:  2014-05-16       Impact factor: 3.039

7.  Functional principal component based landmark analysis for the effects of longitudinal cholesterol profiles on the risk of coronary heart disease.

Authors:  Bin Shi; Peng Wei; Xuelin Huang
Journal:  Stat Med       Date:  2020-11-05       Impact factor: 2.497

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.