Literature DB >> 17879795

Evaluation of internal noise methods for Hotelling observer models.

Yani Zhang1, Binh T Pham, Miguel P Eckstein.   

Abstract

The inclusion of internal noise in model observers is a common method to allow for quantitative comparisons between human and model observer performance in visual detection tasks. In this article, we studied two different strategies for inserting internal noise into Hotelling model observers. In the first strategy, internal noise was added to the output of individual channels: (a) Independent nonuniform channel noise, (b) independent uniform channel noise. In the second strategy, internal noise was added to the decision variable arising from the combination of channel responses. The standard deviation of the zero mean internal noise was either constant or proportional to: (a) the decision variable's standard deviation due to the external noise, (b) the decision variable's variance caused by the external noise, (c) the decision variable magnitude on a trial to trial basis. We tested three model observers: square window Hotelling observer (HO), channelized Hotelling observer (CHO), and Laguerre-Gauss Hotelling observer (LGHO) using a four alternative forced choice (4AFC) signal known exactly but variable task with a simulated signal embedded in real x-ray coronary angiogram backgrounds. The results showed that the internal noise method that led to the best prediction of human performance differed across the studied model observers. The CHO model best predicted human observer performance with the channel internal noise. The HO and LGHO best predicted human observer performance with the decision variable internal noise. The present results might guide researchers with the choice of methods to include internal noise into Hotelling model observers when evaluating and optimizing medical image quality.

Entities:  

Mesh:

Year:  2007        PMID: 17879795     DOI: 10.1118/1.2756603

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  22 in total

1.  Computational and human observer image quality evaluation of low dose, knowledge-based CT iterative reconstruction.

Authors:  Brendan L Eck; Rachid Fahmi; Kevin M Brown; Stanislav Zabic; Nilgoun Raihani; Jun Miao; David L Wilson
Journal:  Med Phys       Date:  2015-10       Impact factor: 4.071

2.  Anthropomorphic model observer performance in three-dimensional detection task for low-contrast computed tomography.

Authors:  Alexandre Ba; Miguel P Eckstein; Damien Racine; Julien G Ott; Francis Verdun; Sabine Kobbe-Schmidt; François O Bochud
Journal:  J Med Imaging (Bellingham)       Date:  2015-12-29

3.  A visual-search model observer for multislice-multiview SPECT images.

Authors:  Howard C Gifford
Journal:  Med Phys       Date:  2013-09       Impact factor: 4.071

4.  Implementation of a channelized Hotelling observer model to assess image quality of x-ray angiography systems.

Authors:  Christopher P Favazza; Kenneth A Fetterly; Nicholas J Hangiandreou; Shuai Leng; Beth A Schueler
Journal:  J Med Imaging (Bellingham)       Date:  2015-03-25

5.  The role of extra-foveal processing in 3D imaging.

Authors:  Miguel P Eckstein; Miguel A Lago; Craig K Abbey
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-10

6.  4D numerical observer for lesion detection in respiratory-gated PET.

Authors:  Auranuch Lorsakul; Quanzheng Li; Cathryn M Trott; Christopher Hoog; Yoann Petibon; Jinsong Ouyang; Andrew F Laine; Georges El Fakhri
Journal:  Med Phys       Date:  2014-10       Impact factor: 4.071

7.  Generalization Evaluation of Machine Learning Numerical Observers for Image Quality Assessment.

Authors:  Mahdi M Kalayeh; Thibault Marin; Jovan G Brankov
Journal:  IEEE Trans Nucl Sci       Date:  2013-06       Impact factor: 1.679

8.  Task Equivalence for Model and Human-Observer Comparisons in SPECT Localization Studies.

Authors:  Anando Sen; Faraz Kalantari; Howard C Gifford
Journal:  IEEE Trans Nucl Sci       Date:  2016-05-19       Impact factor: 1.679

9.  Evaluation of the channelized Hotelling observer with an internal-noise model in a train-test paradigm for cardiac SPECT defect detection.

Authors:  Jovan G Brankov
Journal:  Phys Med Biol       Date:  2013-09-20       Impact factor: 3.609

10.  Virtual assessment of stereoscopic viewing of digital breast tomosynthesis projection images.

Authors:  Gezheng Wen; Ho-Chang Chang; Jacob Reinhold; Joseph Y Lo; Mia K Markey
Journal:  J Med Imaging (Bellingham)       Date:  2018-01-17