Literature DB >> 3430229

Addition of a channel mechanism to the ideal-observer model.

K J Myers1, H H Barrett.   

Abstract

Several authors have measured the detection ability of human observers for objects in correlated (nonwhite) noise. These studies have shown that the human observer has approximately constant efficiency when compared with a nonprewhitening ideal observer. In this paper we add a frequency-selective mechanism to the ideal-observer model, similar to the channel mechanism that has been demonstrated through experiments that measure a subject's ability to detect grating stimuli. For a number of detection and discrimination tasks, the nonprewhitening ideal-observer model and the channelized ideal-observer model yield similar performance predictions. Thus both models seem equally capable of explaining a considerable body of psychophysical data, and it would be difficult to devise an experiment to determine which model is more nearly correct.

Entities:  

Mesh:

Year:  1987        PMID: 3430229     DOI: 10.1364/josaa.4.002447

Source DB:  PubMed          Journal:  J Opt Soc Am A        ISSN: 0740-3232            Impact factor:   2.129


  99 in total

1.  Application of a generalized scan statistic model to evaluate TOF PET images.

Authors:  Suleman Surti; Joel S Karp
Journal:  IEEE Trans Nucl Sci       Date:  2011       Impact factor: 1.679

2.  Experimental determination of object statistics from noisy images.

Authors:  Matthew A Kupinski; Eric Clarkson; John W Hoppin; Liying Chen; Harrison H Barrett
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2003-03       Impact factor: 2.129

3.  Effects of motion, attenuation, and scatter corrections on gated cardiac SPECT reconstruction.

Authors:  Xiaofeng Niu; Yongyi Yang; Mingwu Jin; Miles N Wernick; Michael A King
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

4.  Rapid Computation of LROC Figures of Merit Using Numerical Observers (for SPECT/PET Reconstruction).

Authors:  Parmeshwar Khurd; Gene Gindi
Journal:  IEEE Trans Nucl Sci       Date:  2003       Impact factor: 1.679

5.  Myocardial perfusion SPECT using a rotating multi-segment slant-hole collimator.

Authors:  Chi Liu; Jingyan Xu; Benjamin M W Tsui
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

6.  Detectability of perfusion defect in five-dimensional gated-dynamic cardiac SPECT images.

Authors:  Xiaofeng Niu; Yongyi Yang; Michael A King; Miles N Wernick
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

7.  Rapid Optimization of SPECT Scatter Correction Using Model LROC Observers.

Authors:  Santosh Kulkarni; Parmeshwar Khurd; Lili Zhou; Gene Gindi
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2007

8.  Observer signal-to-noise ratios for the ML-EM algorithm.

Authors:  Craig K Abbey; Harrison H Barrett; Donald W Wilson
Journal:  Proc SPIE Int Soc Opt Eng       Date:  1996-01-01

9.  Computational and human observer image quality evaluation of low dose, knowledge-based CT iterative reconstruction.

Authors:  Brendan L Eck; Rachid Fahmi; Kevin M Brown; Stanislav Zabic; Nilgoun Raihani; Jun Miao; David L Wilson
Journal:  Med Phys       Date:  2015-10       Impact factor: 4.071

10.  New Theoretical Results on Channelized Hotelling Observer Performance Estimation with Known Difference of Class Means.

Authors:  Adam Wunderlich; Frédéric Noo
Journal:  IEEE Trans Nucl Sci       Date:  2013-01-11       Impact factor: 1.679

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.