Accelerated barrier optimization compressed sensing (ABOCS) reconstruction for cone-beam CT: phantom studies.

Tianye Niu1, Lei Zhu.   

Abstract

PURPOSE: Recent advances in compressed sensing (CS) enable accurate CT image reconstruction from highly undersampled and noisy projection measurements, due to the sparsifiable feature of most CT images using total variation (TV). These novel reconstruction methods have demonstrated advantages in clinical applications where radiation dose reduction is critical, such as onboard cone-beam CT (CBCT) imaging in radiation therapy. The image reconstruction using CS is formulated as either a constrained problem to minimize the TV objective within a small and fixed data fidelity error, or an unconstrained problem to minimize the data fidelity error with TV regularization. However, the conventional solutions to the above two formulations are either computationally inefficient or involved with inconsistent regularization parameter tuning, which significantly limit the clinical use of CS-based iterative reconstruction. In this paper, we propose an optimization algorithm for CS reconstruction which overcomes the above two drawbacks.
METHODS: The data fidelity tolerance of CS reconstruction can be well estimated based on the measured data, as most of the projection errors are from Poisson noise after effective data correction for scatter and beam-hardening effects. We therefore adopt the TV optimization framework with a data fidelity constraint. To accelerate the convergence, we first convert such a constrained optimization using a logarithmic barrier method into a form similar to that of the conventional TV regularization based reconstruction but with an automatically adjusted penalty weight. The problem is then solved efficiently by gradient projection with an adaptive Barzilai-Borwein step-size selection scheme. The proposed algorithm is referred to as accelerated barrier optimization for CS (ABOCS), and evaluated using both digital and physical phantom studies.
RESULTS: ABOCS directly estimates the data fidelity tolerance from the raw projection data. Therefore, as demonstrated in both digital Shepp-Logan and physical head phantom studies, consistent reconstruction performances are achieved using the same algorithm parameters on scans with different noise levels and∕or on different objects. On the contrary, the penalty weight in a TV regularization based method needs to be fine-tuned in a large range (up to seven times) to maintain the reconstructed image quality. The improvement of ABOCS on computational efficiency is demonstrated in the comparisons with adaptive-steepest-descent-projection-onto-convex-sets (ASD-POCS), an existing CS reconstruction algorithm also using constrained optimization. ASD-POCS alternatively minimizes the TV objective using adaptive steepest descent (ASD) and the data fidelity error using projection onto convex sets (POCS). For similar image qualities of the Shepp-Logan phantom, ABOCS requires less computation time than ASD-POCS in MATLAB by more than one order of magnitude.
CONCLUSIONS: We propose ABOCS for CBCT reconstruction. As compared to other published CS-based algorithms, our method has attractive features of fast convergence and consistent parameter settings for different datasets. These advantages have been demonstrated on phantom studies.

Entities:  

Mesh:

Year:  2012        PMID: 22830790      PMCID: PMC3412436          DOI: 10.1118/1.4729837

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  29 in total

1.  An iterative approach to the beam hardening correction in cone beam CT.

Authors:  J Hsieh; R C Molthen; C A Dawson; R H Johnson
Journal:  Med Phys       Date:  2000-01       Impact factor: 4.071

2.  Scatter correction method for X-ray CT using primary modulation: theory and preliminary results.

Authors:  Lei Zhu; N Robert Bennett; Rebecca Fahrig
Journal:  IEEE Trans Med Imaging       Date:  2006-12       Impact factor: 10.048

3.  The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75.

Authors:  Martin J Murphy; James Balter; Stephen Balter; Jose A BenComo; Indra J Das; Steve B Jiang; C M Ma; Gustavo H Olivera; Raymond F Rodebaugh; Kenneth J Ruchala; Hiroki Shirato; Fang-Fang Yin
Journal:  Med Phys       Date:  2007-10       Impact factor: 4.071

Review 4.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

5.  A short-scan reconstruction for cone-beam CT using shift-invariant FBP and equal weighting.

Authors:  Lei Zhu; Sungwon Yoon; Rebecca Fahrig
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

6.  Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets.

Authors:  Guang-Hong Chen; Jie Tang; Shuai Leng
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

7.  Tomographic mammography using a limited number of low-dose cone-beam projection images.

Authors:  Tao Wu; Alexander Stewart; Martin Stanton; Thomas McCauley; Walter Phillips; Daniel B Kopans; Richard H Moore; Jeffrey W Eberhard; Beale Opsahl-Ong; Loren Niklason; Mark B Williams
Journal:  Med Phys       Date:  2003-03       Impact factor: 4.071

8.  Simultaneous algebraic reconstruction technique (SART): a superior implementation of the art algorithm.

Authors:  A H Andersen; A C Kak
Journal:  Ultrason Imaging       Date:  1984-01       Impact factor: 1.578

9.  Faster STORM using compressed sensing.

Authors:  Lei Zhu; Wei Zhang; Daniel Elnatan; Bo Huang
Journal:  Nat Methods       Date:  2012-04-22       Impact factor: 28.547

10.  Radiation dose from cone beam computed tomography for image-guided radiation therapy.

Authors:  Monica W K Kan; Lucullus H T Leung; Wicger Wong; Nelson Lam
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-11-05       Impact factor: 7.038

View more
  21 in total

1.  Constrained TpV Minimization for Enhanced Exploitation of Gradient Sparsity: Application to CT Image Reconstruction.

Authors:  Emil Y Sidky; Rick Chartrand; John M Boone; Xiaochuan Pan
Journal:  IEEE J Transl Eng Health Med       Date:  2014-06-30       Impact factor: 3.316

2.  Cone-beam breast computed tomography using ultra-fast image reconstruction with constrained, total-variation minimization for suppression of artifacts.

Authors:  Hsin Wu Tseng; Srinivasan Vedantham; Andrew Karellas
Journal:  Phys Med       Date:  2020-04-28       Impact factor: 2.685

3.  Improving thoracic four-dimensional cone-beam CT reconstruction with anatomical-adaptive image regularization (AAIR).

Authors:  Chun-Chien Shieh; John Kipritidis; Ricky T O'Brien; Benjamin J Cooper; Zdenka Kuncic; Paul J Keall
Journal:  Phys Med Biol       Date:  2015-01-07       Impact factor: 3.609

4.  Sparse-view x-ray CT reconstruction via total generalized variation regularization.

Authors:  Shanzhou Niu; Yang Gao; Zhaoying Bian; Jing Huang; Wufan Chen; Gaohang Yu; Zhengrong Liang; Jianhua Ma
Journal:  Phys Med Biol       Date:  2014-05-19       Impact factor: 3.609

5.  Accelerated fast iterative shrinkage thresholding algorithms for sparsity-regularized cone-beam CT image reconstruction.

Authors:  Qiaofeng Xu; Deshan Yang; Jun Tan; Alex Sawatzky; Mark A Anastasio
Journal:  Med Phys       Date:  2016-04       Impact factor: 4.071

6.  Deep learning-based image quality improvement for low-dose computed tomography simulation in radiation therapy.

Authors:  Tonghe Wang; Yang Lei; Zhen Tian; Xue Dong; Yingzi Liu; Xiaojun Jiang; Walter J Curran; Tian Liu; Hui-Kuo Shu; Xiaofeng Yang
Journal:  J Med Imaging (Bellingham)       Date:  2019-10-24

7.  Dual energy CT with one full scan and a second sparse-view scan using structure preserving iterative reconstruction (SPIR).

Authors:  Tonghe Wang; Lei Zhu
Journal:  Phys Med Biol       Date:  2016-08-23       Impact factor: 3.609

8.  Assessment of prior image induced nonlocal means regularization for low-dose CT reconstruction: Change in anatomy.

Authors:  Hao Zhang; Jianhua Ma; Jing Wang; William Moore; Zhengrong Liang
Journal:  Med Phys       Date:  2017-09       Impact factor: 4.071

9.  Adaptive-weighted total variation minimization for sparse data toward low-dose x-ray computed tomography image reconstruction.

Authors:  Yan Liu; Jianhua Ma; Yi Fan; Zhengrong Liang
Journal:  Phys Med Biol       Date:  2012-11-15       Impact factor: 3.609

10.  Accelerated barrier optimization compressed sensing (ABOCS) for CT reconstruction with improved convergence.

Authors:  Tianye Niu; Xiaojing Ye; Quentin Fruhauf; Michael Petrongolo; Lei Zhu
Journal:  Phys Med Biol       Date:  2014-03-14       Impact factor: 3.609