Literature DB >> 18383687

Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets.

Guang-Hong Chen, Jie Tang, Shuai Leng.   

Abstract

When the number of projections does not satisfy the Shannon/Nyquist sampling requirement, streaking artifacts are inevitable in x-ray computed tomography (CT) images reconstructed using filtered backprojection algorithms. In this letter, the spatial-temporal correlations in dynamic CT imaging have been exploited to sparsify dynamic CT image sequences and the newly proposed compressed sensing (CS) reconstruction method is applied to reconstruct the target image sequences. A prior image reconstructed from the union of interleaved dynamical data sets is utilized to constrain the CS image reconstruction for the individual time frames. This method is referred to as prior image constrained compressed sensing (PICCS). In vivo experimental animal studies were conducted to validate the PICCS algorithm, and the results indicate that PICCS enables accurate reconstruction of dynamic CT images using about 20 view angles, which corresponds to an under-sampling factor of 32. This undersampling factor implies a potential radiation dose reduction by a factor of 32 in myocardial CT perfusion imaging.

Mesh:

Year:  2008        PMID: 18383687      PMCID: PMC2655145          DOI: 10.1118/1.2836423

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint.

Authors:  Kai Tobias Block; Martin Uecker; Jens Frahm
Journal:  Magn Reson Med       Date:  2007-06       Impact factor: 4.668

2.  Sparse MRI: The application of compressed sensing for rapid MR imaging.

Authors:  Michael Lustig; David Donoho; John M Pauly
Journal:  Magn Reson Med       Date:  2007-12       Impact factor: 4.668

3.  Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro-CT.

Authors:  Jiayu Song; Qing H Liu; G Allan Johnson; Cristian T Badea
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

  3 in total
  249 in total

1.  A strategy to decrease partial scan reconstruction artifacts in myocardial perfusion CT: phantom and in vivo evaluation.

Authors:  Juan C Ramirez-Giraldo; Lifeng Yu; Birgit Kantor; Erik L Ritman; Cynthia H McCollough
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

2.  Prior image constrained compressed sensing: implementation and performance evaluation.

Authors:  Pascal Thériault Lauzier; Jie Tang; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

3.  Extraction of tumor motion trajectories using PICCS-4DCBCT: a validation study.

Authors:  Zhihua Qi; Guang-Hong Chen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

4.  A constrained, total-variation minimization algorithm for low-intensity x-ray CT.

Authors:  Emil Y Sidky; Yuval Duchin; Xiaochuan Pan; Christer Ullberg
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

5.  Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

Authors:  Cynthia H McCollough; Guang Hong Chen; Willi Kalender; Shuai Leng; Ehsan Samei; Katsuyuki Taguchi; Ge Wang; Lifeng Yu; Roderic I Pettigrew
Journal:  Radiology       Date:  2012-06-12       Impact factor: 11.105

6.  Simultaneous segmentation and reconstruction: a level set method approach for limited view computed tomography.

Authors:  Sungwon Yoon; Angel R Pineda; Rebecca Fahrig
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

7.  Compressed sensing based cone-beam computed tomography reconstruction with a first-order method.

Authors:  Kihwan Choi; Jing Wang; Lei Zhu; Tae-Suk Suh; Stephen Boyd; Lei Xing
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

8.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

9.  Ultra-High Resolution Photon-Counting Detector CT Reconstruction using Spectral Prior Image Constrained Compressed-Sensing (UHR-SPICCS).

Authors:  Kishore Rajendran; Shengzhen Tao; Dilbar Abdurakhimova; Shuai Leng; Cynthia McCollough
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03

10.  A Feasibility Study of Extracting Tissue Textures From a Previous Full-Dose CT Database as Prior Knowledge for Bayesian Reconstruction of Current Low-Dose CT Images.

Authors:  Yongfeng Gao; Zhengrong Liang; William Moore; Hao Zhang; Marc J Pomeroy; John A Ferretti; Thomas V Bilfinger; Jianhua Ma; Hongbing Lu
Journal:  IEEE Trans Med Imaging       Date:  2019-01-03       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.