Literature DB >> 10659734

An iterative approach to the beam hardening correction in cone beam CT.

J Hsieh1, R C Molthen, C A Dawson, R H Johnson.   

Abstract

In computed tomography (CT), the beam hardening effect has been known to be one of the major sources of deterministic error that leads to inaccuracy and artifact in the reconstructed images. Because of the polychromatic nature of the x-ray source used in CT and the energy-dependent attenuation of most materials, Beer's law no longer holds. As a result, errors are present in the acquired line integrals or measurements of the attenuation coefficients of the scanned object. In the past, many studies have been conducted to combat image artifacts induced by beam hardening. In this paper, we present an iterative beam hardening correction approach for cone beam CT. An algorithm that utilizes a tilted parallel beam geometry is developed and subsequently employed to estimate the projection error and obtain an error estimation image, which is then subtracted from the initial reconstruction. A theoretical analysis is performed to investigate the accuracy of our methods. Phantom and animal experiments are conducted to demonstrate the effectiveness of our approach.

Mesh:

Year:  2000        PMID: 10659734     DOI: 10.1118/1.598853

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  42 in total

1.  Accuracy of CBCT measurements of a human skull.

Authors:  Kivanç Kamburoğlu; Eray Kolsuz; Hakan Kurt; Cenk Kiliç; Tuncer Özen; Candan Semra Paksoy
Journal:  J Digit Imaging       Date:  2011-10       Impact factor: 4.056

2.  Proton dose calculation on scatter-corrected CBCT image: Feasibility study for adaptive proton therapy.

Authors:  Yang-Kyun Park; Gregory C Sharp; Justin Phillips; Brian A Winey
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

Review 3.  Vision 20/20: Single photon counting x-ray detectors in medical imaging.

Authors:  Katsuyuki Taguchi; Jan S Iwanczyk
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

Review 4.  Anniversary paper. Development of x-ray computed tomography: the role of medical physics and AAPM from the 1970s to present.

Authors:  Xiaochuan Pan; Jeffrey Siewerdsen; Patrick J La Riviere; Willi A Kalender
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

Review 5.  Artefacts in CBCT: a review.

Authors:  R Schulze; U Heil; D Gross; D D Bruellmann; E Dranischnikow; U Schwanecke; E Schoemer
Journal:  Dentomaxillofac Radiol       Date:  2011-07       Impact factor: 2.419

6.  Investigation into the optimal linear time-invariant lag correction for radar artifact removal.

Authors:  Jared Starman; Josh Star-Lack; Gary Virshup; Edward Shapiro; Rebecca Fahrig
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

7.  CT to cone-beam CT deformable registration with simultaneous intensity correction.

Authors:  Xin Zhen; Xuejun Gu; Hao Yan; Linghong Zhou; Xun Jia; Steve B Jiang
Journal:  Phys Med Biol       Date:  2012-10-03       Impact factor: 3.609

8.  Fast analytical approach of application specific dose efficient spectrum selection for diagnostic CT imaging and PET attenuation correction.

Authors:  Xue Rui; Yannan Jin; Paul F FitzGerald; Mingye Wu; Adam M Alessio; Paul E Kinahan; Bruno De Man
Journal:  Phys Med Biol       Date:  2016-10-18       Impact factor: 3.609

9.  Experimental study of intracranial hematoma detection with flat panel detector C-arm CT.

Authors:  H Arakawa; M P Marks; H M Do; D M Bouley; N Strobel; T Moore; R Fahrig
Journal:  AJNR Am J Neuroradiol       Date:  2008-01-17       Impact factor: 3.825

10.  Specimen size and porosity can introduce error into microCT-based tissue mineral density measurements.

Authors:  Roberto J Fajardo; Esther Cory; Nipun D Patel; Ara Nazarian; Andres Laib; Rajaram K Manoharan; James E Schmitz; Jeremy M DeSilva; Laura M MacLatchy; Brian D Snyder; Mary L Bouxsein
Journal:  Bone       Date:  2008-09-10       Impact factor: 4.398

View more