Literature DB >> 12674237

Tomographic mammography using a limited number of low-dose cone-beam projection images.

Tao Wu1, Alexander Stewart, Martin Stanton, Thomas McCauley, Walter Phillips, Daniel B Kopans, Richard H Moore, Jeffrey W Eberhard, Beale Opsahl-Ong, Loren Niklason, Mark B Williams.   

Abstract

A method is described for using a limited number (typically 10-50) of low-dose radiographs to reconstruct the three-dimensional (3D) distribution of x-ray attenuation in the breast. The method uses x-ray cone-beam imaging, an electronic digital detector, and constrained nonlinear iterative computational techniques. Images are reconstructed with high resolution in two dimensions and lower resolution in the third dimension. The 3D distribution of attenuation that is projected into one image in conventional mammography can be separated into many layers (typically 30-80 1-mm-thick layers, depending on breast thickness), increasing the conspicuity of features that are often obscured by overlapping structure in a single-projection view. Schemes that record breast images at nonuniform angular increments, nonuniform image exposure, and nonuniform detector resolution are investigated in order to reduce the total x-ray exposure necessary to obtain diagnostically useful 3D reconstructions, and to improve the quality of the reconstructed images for a given exposure. The total patient radiation dose can be comparable to that used for a standard two-view mammogram. The method is illustrated with images from mastectomy specimens, a phantom, and human volunteers. The results show how image quality is affected by various data-collection protocols.

Entities:  

Mesh:

Year:  2003        PMID: 12674237     DOI: 10.1118/1.1543934

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  68 in total

1.  High resolution dual detector volume-of-interest cone beam breast CT--Demonstration with a bench top system.

Authors:  Youtao Shen; Ying Yi; Yuncheng Zhong; Chao-Jen Lai; Xinming Liu; Zhicheng You; Shuaiping Ge; Tianpeng Wang; Chris C Shaw
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  High resolution stationary digital breast tomosynthesis using distributed carbon nanotube x-ray source array.

Authors:  Xin Qian; Andrew Tucker; Emily Gidcumb; Jing Shan; Guang Yang; Xiomara Calderon-Colon; Shabana Sultana; Jianping Lu; Otto Zhou; Derrek Spronk; Frank Sprenger; Yiheng Zhang; Don Kennedy; Tom Farbizio; Zhenxue Jing
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

3.  Image quality of microcalcifications in digital breast tomosynthesis: effects of projection-view distributions.

Authors:  Yao Lu; Heang-Ping Chan; Jun Wei; Mitch Goodsitt; Paul L Carson; Lubomir Hadjiiski; Andrea Schmitz; Jeffrey W Eberhard; Bernhard E H Claus
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

4.  Characterization of masses in digital breast tomosynthesis: comparison of machine learning in projection views and reconstructed slices.

Authors:  Heang-Ping Chan; Yi-Ta Wu; Berkman Sahiner; Jun Wei; Mark A Helvie; Yiheng Zhang; Richard H Moore; Daniel B Kopans; Lubomir Hadjiiski; Ted Way
Journal:  Med Phys       Date:  2010-07       Impact factor: 4.071

5.  Task-based assessment of breast tomosynthesis: effect of acquisition parameters and quantum noise.

Authors:  I Reiser; R M Nishikawa
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

6.  The quantitative potential for breast tomosynthesis imaging.

Authors:  Christina M Shafer; Ehsan Samei; Joseph Y Lo
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

7.  Simultaneous segmentation and reconstruction: a level set method approach for limited view computed tomography.

Authors:  Sungwon Yoon; Angel R Pineda; Rebecca Fahrig
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

8.  Anatomical background and generalized detectability in tomosynthesis and cone-beam CT.

Authors:  G J Gang; D J Tward; J Lee; J H Siewerdsen
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

9.  A novel approach to digital breast tomosynthesis for simultaneous acquisition of 2D and 3D images.

Authors:  Sara Vecchio; Achille Albanese; Paolo Vignoli; Angelo Taibi
Journal:  Eur Radiol       Date:  2010-12-31       Impact factor: 5.315

10.  Comparison study of reconstruction algorithms for prototype digital breast tomosynthesis using various breast phantoms.

Authors:  Ye-seul Kim; Hye-suk Park; Haeng-Hwa Lee; Young-Wook Choi; Jae-Gu Choi; Hak Hee Kim; Hee-Joung Kim
Journal:  Radiol Med       Date:  2015-09-18       Impact factor: 3.469

View more