Literature DB >> 24842150

Sparse-view x-ray CT reconstruction via total generalized variation regularization.

Shanzhou Niu1, Yang Gao, Zhaoying Bian, Jing Huang, Wufan Chen, Gaohang Yu, Zhengrong Liang, Jianhua Ma.   

Abstract

Sparse-view CT reconstruction algorithms via total variation (TV) optimize the data iteratively on the basis of a noise- and artifact-reducing model, resulting in significant radiation dose reduction while maintaining image quality. However, the piecewise constant assumption of TV minimization often leads to the appearance of noticeable patchy artifacts in reconstructed images. To obviate this drawback, we present a penalized weighted least-squares (PWLS) scheme to retain the image quality by incorporating the new concept of total generalized variation (TGV) regularization. We refer to the proposed scheme as 'PWLS-TGV' for simplicity. Specifically, TGV regularization utilizes higher order derivatives of the objective image, and the weighted least-squares term considers data-dependent variance estimation, which fully contribute to improving the image quality with sparse-view projection measurement. Subsequently, an alternating optimization algorithm was adopted to minimize the associative objective function. To evaluate the PWLS-TGV method, both qualitative and quantitative studies were conducted by using digital and physical phantoms. Experimental results show that the present PWLS-TGV method can achieve images with several noticeable gains over the original TV-based method in terms of accuracy and resolution properties.

Entities:  

Mesh:

Year:  2014        PMID: 24842150      PMCID: PMC4219274          DOI: 10.1088/0031-9155/59/12/2997

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  39 in total

1.  Accelerated barrier optimization compressed sensing (ABOCS) reconstruction for cone-beam CT: phantom studies.

Authors:  Tianye Niu; Lei Zhu
Journal:  Med Phys       Date:  2012-07       Impact factor: 4.071

2.  Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction.

Authors:  Pascal Theriault Lauzier; Guang-Hong Chen
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

3.  Optimization-based reconstruction of sparse images from few-view projections.

Authors:  Xiao Han; Junguo Bian; Erik L Ritman; Emil Y Sidky; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2012-07-31       Impact factor: 3.609

4.  SR-NLM: a sinogram restoration induced non-local means image filtering for low-dose computed tomography.

Authors:  Zhaoying Bian; Jianhua Ma; Jing Huang; Hua Zhang; Shanzhou Niu; Qianjin Feng; Zhengrong Liang; Wufan Chen
Journal:  Comput Med Imaging Graph       Date:  2013-06-24       Impact factor: 4.790

5.  Low-dose X-ray CT reconstruction via dictionary learning.

Authors:  Qiong Xu; Hengyong Yu; Xuanqin Mou; Lei Zhang; Jiang Hsieh; Ge Wang
Journal:  IEEE Trans Med Imaging       Date:  2012-04-20       Impact factor: 10.048

6.  Adaptive-weighted total variation minimization for sparse data toward low-dose x-ray computed tomography image reconstruction.

Authors:  Yan Liu; Jianhua Ma; Yi Fan; Zhengrong Liang
Journal:  Phys Med Biol       Date:  2012-11-15       Impact factor: 3.609

7.  A limited-angle CT reconstruction method based on anisotropic TV minimization.

Authors:  Zhiqiang Chen; Xin Jin; Liang Li; Ge Wang
Journal:  Phys Med Biol       Date:  2013-03-08       Impact factor: 3.609

8.  Quantifying admissible undersampling for sparsity-exploiting iterative image reconstruction in X-ray CT.

Authors:  Jakob S Jørgensen; Emil Y Sidky; Xiaochuan Pan
Journal:  IEEE Trans Med Imaging       Date:  2012-11-27       Impact factor: 10.048

9.  Few-view single photon emission computed tomography (SPECT) reconstruction based on a blurred piecewise constant object model.

Authors:  Paul A Wolf; Jakob S Jørgensen; Taly G Schmidt; Emil Y Sidky
Journal:  Phys Med Biol       Date:  2013-07-29       Impact factor: 3.609

10.  Iterative image reconstruction for cerebral perfusion CT using a pre-contrast scan induced edge-preserving prior.

Authors:  Jianhua Ma; Hua Zhang; Yang Gao; Jing Huang; Zhengrong Liang; Qianjing Feng; Wufan Chen
Journal:  Phys Med Biol       Date:  2012-10-26       Impact factor: 3.609

View more
  39 in total

1.  Tomographic Cherenkov-excited luminescence scanned imaging with multiple pinhole beams recovered via back-projection reconstruction.

Authors:  Mengyu J Jia; Xu Cao; Jason R Gunn; Petr Bruza; Shudong Jiang; Brian W Pogue
Journal:  Opt Lett       Date:  2019-04-01       Impact factor: 3.776

2.  [Influence of projection data correction on digital breast tomosynthesis imaging].

Authors:  Xin-Yu Zhang; Hua Zhang; Zhao-Ying Bian; Dong Zeng; Ji He; Xiu-Mei Tian; Jian-Hua Ma; Jing Huang
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2017-03-20

3.  Cone-beam breast computed tomography using ultra-fast image reconstruction with constrained, total-variation minimization for suppression of artifacts.

Authors:  Hsin Wu Tseng; Srinivasan Vedantham; Andrew Karellas
Journal:  Phys Med       Date:  2020-04-28       Impact factor: 2.685

4.  Low-dose X-ray computed tomography image reconstruction with a combined low-mAs and sparse-view protocol.

Authors:  Yang Gao; Zhaoying Bian; Jing Huang; Yunwan Zhang; Shanzhou Niu; Qianjin Feng; Wufan Chen; Zhengrong Liang; Jianhua Ma
Journal:  Opt Express       Date:  2014-06-16       Impact factor: 3.894

Review 5.  Regularization strategies in statistical image reconstruction of low-dose x-ray CT: A review.

Authors:  Hao Zhang; Jing Wang; Dong Zeng; Xi Tao; Jianhua Ma
Journal:  Med Phys       Date:  2018-09-10       Impact factor: 4.071

6.  [Total generalized variation minimization based on projection data for low?dose CT reconstruction].

Authors:  Shan-Zhou Niu; Heng Wu; Ze-Feng Yu; Zi-Jun Zheng; Gao-Hang Yu
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2017-12-20

7.  4D cone-beam computed tomography (CBCT) using a moving blocker for simultaneous radiation dose reduction and scatter correction.

Authors:  Cong Zhao; Yuncheng Zhong; Xinhui Duan; You Zhang; Xiaokun Huang; Jing Wang; Mingwu Jin
Journal:  Phys Med Biol       Date:  2018-05-29       Impact factor: 3.609

8.  Statistical CT reconstruction using region-aware texture preserving regularization learning from prior normal-dose CT image.

Authors:  Xiao Jia; Yuting Liao; Dong Zeng; Hao Zhang; Yuanke Zhang; Ji He; Zhaoying Bian; Yongbo Wang; Xi Tao; Zhengrong Liang; Jing Huang; Jianhua Ma
Journal:  Phys Med Biol       Date:  2018-11-20       Impact factor: 3.609

9.  An Efficient Augmented Lagrangian Method for Statistical X-Ray CT Image Reconstruction.

Authors:  Jiaojiao Li; Shanzhou Niu; Jing Huang; Zhaoying Bian; Qianjin Feng; Gaohang Yu; Zhengrong Liang; Wufan Chen; Jianhua Ma
Journal:  PLoS One       Date:  2015-10-23       Impact factor: 3.240

10.  Low-dose cerebral perfusion computed tomography image restoration via low-rank and total variation regularizations.

Authors:  Shanzhou Niu; Shanli Zhang; Jing Huang; Zhaoying Bian; Wufan Chen; Gaohang Yu; Zhengrong Liang; Jianhua Ma
Journal:  Neurocomputing       Date:  2016-03-28       Impact factor: 5.719

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.