Literature DB >> 24625411

Accelerated barrier optimization compressed sensing (ABOCS) for CT reconstruction with improved convergence.

Tianye Niu1, Xiaojing Ye, Quentin Fruhauf, Michael Petrongolo, Lei Zhu.   

Abstract

Recently, we proposed a new algorithm of accelerated barrier optimization compressed sensing (ABOCS) for iterative CT reconstruction. The previous implementation of ABOCS uses gradient projection (GP) with a Barzilai-Borwein (BB) step-size selection scheme (GP-BB) to search for the optimal solution. The algorithm does not converge stably due to its non-monotonic behavior. In this paper, we further improve the convergence of ABOCS using the unknown-parameter Nesterov (UPN) method and investigate the ABOCS reconstruction performance on clinical patient data. Comparison studies are carried out on reconstructions of computer simulation, a physical phantom and a head-and-neck patient. In all of these studies, the ABOCS results using UPN show more stable and faster convergence than those of the GP-BB method and a state-of-the-art Bregman-type method. As shown in the simulation study of the Shepp-Logan phantom, UPN achieves the same image quality as those of GP-BB and the Bregman-type methods, but reduces the iteration numbers by up to 50% and 90%, respectively. In the Catphan©600 phantom study, a high-quality image with relative reconstruction error (RRE) less than 3% compared to the full-view result is obtained using UPN with 17% projections (60 views). In the conventional filtered-backprojection reconstruction, the corresponding RRE is more than 15% on the same projection data. The superior performance of ABOCS with the UPN implementation is further demonstrated on the head-and-neck patient. Using 25% projections (91 views), the proposed method reduces the RRE from 21% as in the filtered backprojection (FBP) results to 7.3%. In conclusion, we propose UPN for ABOCS implementation. As compared to GP-BB and the Bregman-type methods, the new method significantly improves the convergence with higher stability and fewer iterations.

Entities:  

Mesh:

Year:  2014        PMID: 24625411      PMCID: PMC4080804          DOI: 10.1088/0031-9155/59/7/1801

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  30 in total

1.  Fast compressed sensing-based CBCT reconstruction using Barzilai-Borwein formulation for application to on-line IGRT.

Authors:  Justin C Park; Bongyong Song; Jin Sung Kim; Sung Ho Park; Ho Kyung Kim; Zhaowei Liu; Tae Suk Suh; William Y Song
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

2.  A constrained, total-variation minimization algorithm for low-intensity x-ray CT.

Authors:  Emil Y Sidky; Yuval Duchin; Xiaochuan Pan; Christer Ullberg
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

3.  Scatter correction for cone-beam CT in radiation therapy.

Authors:  Lei Zhu; Yaoqin Xie; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

4.  Characterization of statistical prior image constrained compressed sensing. I. Applications to time-resolved contrast-enhanced CT.

Authors:  Pascal Theriault Lauzier; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.071

5.  Accelerated barrier optimization compressed sensing (ABOCS) reconstruction for cone-beam CT: phantom studies.

Authors:  Tianye Niu; Lei Zhu
Journal:  Med Phys       Date:  2012-07       Impact factor: 4.071

6.  Optimization-based reconstruction of sparse images from few-view projections.

Authors:  Xiao Han; Junguo Bian; Erik L Ritman; Emil Y Sidky; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2012-07-31       Impact factor: 3.609

7.  Perfusion measurements by micro-CT using prior image constrained compressed sensing (PICCS): initial phantom results.

Authors:  Brian E Nett; Robert Brauweiler; Willi Kalender; Howard Rowley; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2010-04-01       Impact factor: 3.609

8.  Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction?

Authors:  Xiaochuan Pan; Emil Y Sidky; Michael Vannier
Journal:  Inverse Probl       Date:  2009-01-01       Impact factor: 2.407

9.  A prospective evaluation of dose reduction and image quality in chest CT using adaptive statistical iterative reconstruction.

Authors:  Jonathon Leipsic; Giang Nguyen; Jaqueline Brown; Don Sin; John R Mayo
Journal:  AJR Am J Roentgenol       Date:  2010-11       Impact factor: 3.959

10.  Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT.

Authors:  Junguo Bian; Jeffrey H Siewerdsen; Xiao Han; Emil Y Sidky; Jerry L Prince; Charles A Pelizzari; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2010-10-20       Impact factor: 3.609

View more
  12 in total

1.  Accelerated statistical reconstruction for C-arm cone-beam CT using Nesterov's method.

Authors:  Adam S Wang; J Webster Stayman; Yoshito Otake; Sebastian Vogt; Gerhard Kleinszig; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

2.  Towards the clinical implementation of iterative low-dose cone-beam CT reconstruction in image-guided radiation therapy: cone/ring artifact correction and multiple GPU implementation.

Authors:  Hao Yan; Xiaoyu Wang; Feng Shi; Ti Bai; Michael Folkerts; Laura Cervino; Steve B Jiang; Xun Jia
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

3.  Accelerated fast iterative shrinkage thresholding algorithms for sparsity-regularized cone-beam CT image reconstruction.

Authors:  Qiaofeng Xu; Deshan Yang; Jun Tan; Alex Sawatzky; Mark A Anastasio
Journal:  Med Phys       Date:  2016-04       Impact factor: 4.071

4.  Data correlation based noise level estimation for cone beam projection data.

Authors:  Ti Bai; Hao Yan; Luo Ouyang; David Staub; Jing Wang; Xun Jia; Steve B Jiang; Xuanqin Mou
Journal:  J Xray Sci Technol       Date:  2017       Impact factor: 1.535

5.  Compressive sensing in medical imaging.

Authors:  Christian G Graff; Emil Y Sidky
Journal:  Appl Opt       Date:  2015-03-10       Impact factor: 1.980

6.  Noise Suppression for Dual-Energy CT Through Entropy Minimization.

Authors:  Michael Petrongolo; Lei Zhu
Journal:  IEEE Trans Med Imaging       Date:  2015-05-01       Impact factor: 10.048

7.  Z-Index Parameterization for Volumetric CT Image Reconstruction via 3-D Dictionary Learning.

Authors:  Ti Bai; Hao Yan; Xun Jia; Steve Jiang; Ge Wang; Xuanqin Mou
Journal:  IEEE Trans Med Imaging       Date:  2017-10-05       Impact factor: 10.048

8.  Improving Low-dose Cardiac CT Images based on 3D Sparse Representation.

Authors:  Luyao Shi; Yining Hu; Yang Chen; Xindao Yin; Huazhong Shu; Limin Luo; Jean-Louis Coatrieux
Journal:  Sci Rep       Date:  2016-03-16       Impact factor: 4.379

9.  Fast alternating projection methods for constrained tomographic reconstruction.

Authors:  Li Liu; Yongxin Han; Mingwu Jin
Journal:  PLoS One       Date:  2017-03-02       Impact factor: 3.240

10.  Combining Acceleration Techniques for Low-Dose X-Ray Cone Beam Computed Tomography Image Reconstruction.

Authors:  Hsuan-Ming Huang; Ing-Tsung Hsiao
Journal:  Biomed Res Int       Date:  2017-06-05       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.