Literature DB >> 31673567

Deep learning-based image quality improvement for low-dose computed tomography simulation in radiation therapy.

Tonghe Wang1, Yang Lei1, Zhen Tian1, Xue Dong1, Yingzi Liu1, Xiaojun Jiang1, Walter J Curran1, Tian Liu1, Hui-Kuo Shu1, Xiaofeng Yang1.   

Abstract

Low-dose computed tomography (CT) is desirable for treatment planning and simulation in radiation therapy. Multiple rescanning and replanning during the treatment course with a smaller amount of dose than a single conventional full-dose CT simulation is a crucial step in adaptive radiation therapy. We developed a machine learning-based method to improve image quality of low-dose CT for radiation therapy treatment simulation. We used a residual block concept and a self-attention strategy with a cycle-consistent adversarial network framework. A fully convolution neural network with residual blocks and attention gates (AGs) was used in the generator to enable end-to-end transformation. We have collected CT images from 30 patients treated with frameless brain stereotactic radiosurgery (SRS) for this study. These full-dose images were used to generate projection data, which were then added with noise to simulate the low-mAs scanning scenario. Low-dose CT images were reconstructed from this noise-contaminated projection data and were fed into our network along with the original full-dose CT images for training. The performance of our network was evaluated by quantitatively comparing the high-quality CT images generated by our method with the original full-dose images. When mAs is reduced to 0.5% of the original CT scan, the mean square error of the CT images obtained by our method is ∼ 1.6 % , with respect to the original full-dose images. The proposed method successfully improved the noise, contract-to-noise ratio, and nonuniformity level to be close to those of full-dose CT images and outperforms a state-of-the-art iterative reconstruction method. Dosimetric studies show that the average differences of dose-volume histogram metrics are < 0.1    Gy ( p > 0.05 ). These quantitative results strongly indicate that the denoised low-dose CT images using our method maintains image accuracy and quality and are accurate enough for dose calculation in current CT simulation of brain SRS treatment. We also demonstrate the great potential for low-dose CT in the process of simulation and treatment planning.
© 2019 Society of Photo-Optical Instrumentation Engineers (SPIE).

Entities:  

Keywords:  computed tomography; low dose; machine learning; radiation therapy

Year:  2019        PMID: 31673567      PMCID: PMC6811730          DOI: 10.1117/1.JMI.6.4.043504

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  38 in total

1.  Statistical image reconstruction for polyenergetic X-ray computed tomography.

Authors:  Idris A Elbakri; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2002-02       Impact factor: 10.048

Review 2.  Radiation risk from medical imaging.

Authors:  Eugene C Lin
Journal:  Mayo Clin Proc       Date:  2010-12       Impact factor: 7.616

Review 3.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

4.  Model-Based Iterative Reconstruction for Dual-Energy X-Ray CT Using a Joint Quadratic Likelihood Model.

Authors:  Ruoqiao Zhang; Jean-Baptiste Thibault; Charles A Bouman; Ken D Sauer; Jiang Hsieh
Journal:  IEEE Trans Med Imaging       Date:  2013-09-17       Impact factor: 10.048

5.  Plasmodium life cycle stage classification based quantification of malaria parasitaemia in thin blood smears.

Authors:  Naveed Abbas; Tanzila Saba; Amjad Rehman; Zahid Mehmood; Hoshang Kolivand; Mueen Uddin; Adeel Anjum
Journal:  Microsc Res Tech       Date:  2018-12-21       Impact factor: 2.769

6.  Feature enhancement framework for brain tumor segmentation and classification.

Authors:  Bilal Tahir; Sajid Iqbal; M Usman Ghani Khan; Tanzila Saba; Zahid Mehmood; Adeel Anjum; Toqeer Mahmood
Journal:  Microsc Res Tech       Date:  2019-02-15       Impact factor: 2.769

7.  Noise suppression for dual-energy CT via penalized weighted least-square optimization with similarity-based regularization.

Authors:  Joseph Harms; Tonghe Wang; Michael Petrongolo; Tianye Niu; Lei Zhu
Journal:  Med Phys       Date:  2016-05       Impact factor: 4.071

8.  MRI-based pseudo CT synthesis using anatomical signature and alternating random forest with iterative refinement model.

Authors:  Yang Lei; Jiwoong Jason Jeong; Tonghe Wang; Hui-Kuo Shu; Pretesh Patel; Sibo Tian; Tian Liu; Hyunsuk Shim; Hui Mao; Ashesh B Jani; Walter J Curran; Xiaofeng Yang
Journal:  J Med Imaging (Bellingham)       Date:  2018-12-05

9.  Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements.

Authors:  W A Kalender; H Wolf; C Suess
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

10.  Learning-based automatic segmentation of arteriovenous malformations on contrast CT images in brain stereotactic radiosurgery.

Authors:  Tonghe Wang; Yang Lei; Sibo Tian; Xiaojun Jiang; Jun Zhou; Tian Liu; Sean Dresser; Walter J Curran; Hui-Kuo Shu; Xiaofeng Yang
Journal:  Med Phys       Date:  2019-05-21       Impact factor: 4.071

View more
  6 in total

1.  Real-time liver tumor localization via a single x-ray projection using deep graph neural network-assisted biomechanical modeling.

Authors:  Hua-Chieh Shao; Jing Wang; Ti Bai; Jaehee Chun; Justin C Park; Steve Jiang; You Zhang
Journal:  Phys Med Biol       Date:  2022-05-24       Impact factor: 4.174

Review 2.  Machine learning in quantitative PET: A review of attenuation correction and low-count image reconstruction methods.

Authors:  Tonghe Wang; Yang Lei; Yabo Fu; Walter J Curran; Tian Liu; Jonathon A Nye; Xiaofeng Yang
Journal:  Phys Med       Date:  2020-07-29       Impact factor: 2.685

3.  CBCT-based synthetic CT generation using deep-attention cycleGAN for pancreatic adaptive radiotherapy.

Authors:  Yingzi Liu; Yang Lei; Tonghe Wang; Yabo Fu; Xiangyang Tang; Walter J Curran; Tian Liu; Pretesh Patel; Xiaofeng Yang
Journal:  Med Phys       Date:  2020-03-28       Impact factor: 4.071

Review 4.  A review of deep learning based methods for medical image multi-organ segmentation.

Authors:  Yabo Fu; Yang Lei; Tonghe Wang; Walter J Curran; Tian Liu; Xiaofeng Yang
Journal:  Phys Med       Date:  2021-05-13       Impact factor: 2.685

Review 5.  A review on medical imaging synthesis using deep learning and its clinical applications.

Authors:  Tonghe Wang; Yang Lei; Yabo Fu; Jacob F Wynne; Walter J Curran; Tian Liu; Xiaofeng Yang
Journal:  J Appl Clin Med Phys       Date:  2020-12-11       Impact factor: 2.102

Review 6.  Principles and Perspectives of Radiographic Imaging with Muons.

Authors:  Luigi Cimmino
Journal:  J Imaging       Date:  2021-11-26
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.