Scatter correction method for X-ray CT using primary modulation: theory and preliminary results.

Lei Zhu1, N Robert Bennett, Rebecca Fahrig.   

Abstract

An X-ray system with a large area detector has high scatter-to-primary ratios (SPRs), which result in severe artifacts in reconstructed computed tomography (CT) images. A scatter correction algorithm is introduced that provides effective scatter correction but does not require additional patient exposure. The key hypothesis of the algorithm is that the high-frequency components of the X-ray spatial distribution do not result in strong high-frequency signals in the scatter. A calibration sheet with a checkerboard pattern of semitransparent blockers (a "primary modulator") is inserted between the X-ray source and the object. The primary distribution is partially modulated by a high-frequency function, while the scatter distribution still has dominant low-frequency components, based on the hypothesis. Filtering and demodulation techniques suffice to extract the low-frequency components of the primary and hence obtain the scatter estimation. The hypothesis was validated using Monte Carlo (MC) simulation, and the algorithm was evaluated by both MC simulations and physical experiments. Reconstructions of a software humanoid phantom suggested system parameters in the physical implementation and showed that the proposed method reduced the relative mean square error of the reconstructed image in the central region of interest from 74.2% to below 1%. In preliminary physical experiments on the standard evaluation phantom, this error was reduced from 31.8% to 2.3%, and it was also demonstrated that the algorithm has no noticeable impact on the resolution of the reconstructed image in spite of the filter-based approach. Although the proposed scatter correction technique was implemented for X-ray CT, it can also be used in other X-ray imaging applications, as long as a primary modulator can be inserted between the X-ray source and the imaged object.

Entities:  

Mesh:

Year:  2006        PMID: 17167993     DOI: 10.1109/tmi.2006.884636

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  58 in total

1.  Scatter correction for full-fan volumetric CT using a stationary beam blocker in a single full scan.

Authors:  Tianye Niu; Lei Zhu
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

2.  Monte Carlo evaluation of scatter mitigation strategies in cone-beam CT.

Authors:  Dimitrios Lazos; Jeffrey F Williamson
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

3.  Modulator design for x-ray scatter correction using primary modulation: material selection.

Authors:  Hewei Gao; Lei Zhu; Rebecca Fahrig
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

4.  Noise suppression in scatter correction for cone-beam CT.

Authors:  Lei Zhu; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

5.  X-ray scatter correction method for dedicated breast computed tomography.

Authors:  Ioannis Sechopoulos
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

6.  Scatter correction for cone-beam CT in radiation therapy.

Authors:  Lei Zhu; Yaoqin Xie; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

7.  Scatter Reduction and Correction for Dual-Source Cone-Beam CT Using Prepatient Grids.

Authors:  Lei Ren; Yingxuan Chen; You Zhang; William Giles; Jianyue Jin; Fang-Fang Yin
Journal:  Technol Cancer Res Treat       Date:  2015-05-24

8.  Transmission characteristics of a two dimensional antiscatter grid prototype for CBCT.

Authors:  Cem Altunbas; Brian Kavanagh; Timur Alexeev; Moyed Miften
Journal:  Med Phys       Date:  2017-06-16       Impact factor: 4.071

9.  4D cone-beam computed tomography (CBCT) using a moving blocker for simultaneous radiation dose reduction and scatter correction.

Authors:  Cong Zhao; Yuncheng Zhong; Xinhui Duan; You Zhang; Xiaokun Huang; Jing Wang; Mingwu Jin
Journal:  Phys Med Biol       Date:  2018-05-29       Impact factor: 3.609

10.  Experimental study of intracranial hematoma detection with flat panel detector C-arm CT.

Authors:  H Arakawa; M P Marks; H M Do; D M Bouley; N Strobel; T Moore; R Fahrig
Journal:  AJNR Am J Neuroradiol       Date:  2008-01-17       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.