Literature DB >> 21915607

High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: initial experience.

Martin Beeres1, Boris Schell, Aristidis Mastragelopoulos, Eva Herrmann, Josef Matthias Kerl, Tatjana Gruber-Rouh, Clara Lee, Petra Siebenhandl, Boris Bodelle, Stephan Zangos, Thomas J Vogl, Volkmar Jacobi, Ralf W Bauer.   

Abstract

OBJECTIVE: To investigate the feasibility, image quality and radiation dose for high-pitch dual-source CT angiography (CTA) of the whole aorta without ECG synchronisation.
METHODS: Each group of 40 patients underwent CTA either on a 16-slice (group 1) or dual-source CT device with conventional single-source (group 2) or high-pitch mode with a pitch of 3.0 (group 3). The presence of motion or stair-step artefacts of the thoracic aorta was independently assessed by two readers.
RESULTS: Subjective and objective scoring of motion and artefacts were significantly reduced in the high-pitch examination protocol (p < 0.05). The imaging length was not significantly different, but the imaging time was significantly (p < 0.001) shorter in the high-pitch group (12.2 vs. 7.4 vs. 1.7 s for groups 1, 2 and 3). The ascending aorta and the coronary ostia were reliably evaluable in all patients of group 3 without motion artefacts as well.
CONCLUSION: High-pitch dual-source CT angiography of the whole aorta is feasible in unselected patients. As a significant advantage over regular pitch protocols, motion-free imaging of the aorta is possible without ECG synchronisation. Thus, this CT mode bears potential to become a standard CT protocol before trans-catheter aortic valve implantation (TAVI).

Entities:  

Mesh:

Year:  2011        PMID: 21915607     DOI: 10.1007/s00330-011-2257-5

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  16 in total

1.  Thoracic aorta: motion artifact reduction with retrospective and prospective electrocardiography-assisted multi-detector row CT.

Authors:  Justus E Roos; Jürgen K Willmann; Dominik Weishaupt; Mario Lachat; Borut Marincek; Paul R Hilfiker
Journal:  Radiology       Date:  2002-01       Impact factor: 11.105

2.  Motion artifacts of the aorta simulating aortic dissection on spiral CT.

Authors:  S D Qanadli; M El Hajjam; B Mesurolle; L Lavisse; O Jourdan; B Randoux; S Chagnon; P Lacombe
Journal:  J Comput Assist Tomogr       Date:  1999 Jan-Feb       Impact factor: 1.826

3.  Hypervascular liver tumors: low tube voltage, high tube current multi-detector row CT for enhanced detection--phantom study.

Authors:  Sebastian T Schindera; Rendon C Nelson; Srinivasan Mukundan; Erik K Paulson; Tracy A Jaffe; Chad M Miller; David M DeLong; Keigo Kawaji; Terry T Yoshizumi; Ehsan Samei
Journal:  Radiology       Date:  2008-01       Impact factor: 11.105

4.  Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: image reconstruction and assessment of image quality.

Authors:  Thomas G Flohr; Shuai Leng; Lifeng Yu; Thomas Aiimendinger; Herbert Bruder; Martin Petersilka; Christian D Eusemann; Karl Stierstorfer; Bernhard Schmidt; Cynthia H McCollough
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

5.  Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience.

Authors:  Michael Lell; Mohamed Marwan; Tiziano Schepis; Tobias Pflederer; Katharina Anders; Thomas Flohr; Thomas Allmendinger; Willi Kalender; Dirk Ertel; Carsten Thierfelder; Axel Kuettner; Dieter Ropers; Werner G Daniel; Stephan Achenbach
Journal:  Eur Radiol       Date:  2009-11       Impact factor: 5.315

Review 6.  Transcatheter aortic valve implantation: review of the nature, management, and avoidance of procedural complications.

Authors:  Jean-Bernard Masson; Jan Kovac; Gerhard Schuler; Jian Ye; Anson Cheung; Samir Kapadia; Murat E Tuzcu; Susheel Kodali; Martin B Leon; John G Webb
Journal:  JACC Cardiovasc Interv       Date:  2009-09       Impact factor: 11.195

7.  Low-kilovoltage, high-tube-current MDCT of liver in thin adults: pilot study evaluating radiation dose, image quality, and display settings.

Authors:  Takeshi Nakaura; Kazuo Awai; Seitaro Oda; Yoshinori Funama; Kazunori Harada; Shouzaburou Uemura; Yasuyuki Yamashita
Journal:  AJR Am J Roentgenol       Date:  2011-06       Impact factor: 3.959

8.  Saving dose in triple-rule-out computed tomography examination using a high-pitch dual spiral technique.

Authors:  Wieland H Sommer; Jan C Schenzle; Christoph R Becker; Konstantin Nikolaou; Anno Graser; Gisela Michalski; Klement Neumaier; Maximilian F Reiser; Thorsten R C Johnson
Journal:  Invest Radiol       Date:  2010-02       Impact factor: 6.016

9.  320-row CT coronary angiography: effect of 100-kV tube voltages on image quality, contrast volume, and radiation dose.

Authors:  Chuanchen Zhang; Zhaoqi Zhang; Zixu Yan; Lei Xu; Wei Yu; Rui Wang
Journal:  Int J Cardiovasc Imaging       Date:  2010-11-26       Impact factor: 2.357

10.  High-pitch dual-source CT angiography of the thoracic and abdominal aorta: is simultaneous coronary artery assessment possible?

Authors:  Robert Goetti; Stephan Baumüller; Gudrun Feuchtner; Paul Stolzmann; Christoph Karlo; Hatem Alkadhi; Sebastian Leschka
Journal:  AJR Am J Roentgenol       Date:  2010-04       Impact factor: 3.959

View more
  17 in total

1.  Improved visual delineation of the intimal flap in Stanford type A and B dissections at 3rd generation dual-source high-pitch CT angiography.

Authors:  Martin Beeres; Andreas M Bucher; Julian L Wichmann; Claudia Frellesen; Jan E Scholtz; Moritz Albrecht; Boris Bodelle; Nour-Eldin A Nour-Eldin; Clara Lee; Moritz Kaup; Thomas J Vogl; Tatjana Gruber-Rouh
Journal:  Radiol Med       Date:  2016-04-21       Impact factor: 3.469

2.  Iterative reconstruction in single-source dual-energy CT angiography: feasibility of low and ultra-low volume contrast medium protocols.

Authors:  Ping Hou; Xiangnan Feng; Jie Liu; Yue Zhou; Yaojun Jiang; Xiaochen Jiang; Jianbo Gao
Journal:  Br J Radiol       Date:  2017-06-23       Impact factor: 3.039

Review 3.  Noninvasive aortic imaging.

Authors:  Vinit Baliyan; Daniel Verdini; Nandini M Meyersohn
Journal:  Cardiovasc Diagn Ther       Date:  2018-04

4.  The feasibility of high-pitch acquisition protocol for imaging of the pediatric abdomen by dual-source CT.

Authors:  Eray Atlı; Erhan Akpınar; Emre Ünal; Berna Oğuz Sayan; Mithat Haliloğlu
Journal:  Jpn J Radiol       Date:  2018-05-28       Impact factor: 2.374

5.  High-pitch dual-source CT angiography of supra-aortic arteries: assessment of image quality and radiation dose.

Authors:  A Korn; M Fenchel; B Bender; S Danz; C Thomas; D Ketelsen; C D Claussen; G Moonis; B Krauss; M Heuschmid; U Ernemann; H Brodoefel
Journal:  Neuroradiology       Date:  2012-12-08       Impact factor: 2.804

6.  Is ECG triggering for motion artefact reduction in dual-source CT angiography of the ascending aorta still required with high-pitch scanning? The role of ECG-gating in high-pitch dual-source CT of the ascending aorta.

Authors:  Alice Wielandner; Dietrich Beitzke; Ruediger Schernthaner; Florian Wolf; Christina Langenberger; Alfred Stadler; Christian Loewe
Journal:  Br J Radiol       Date:  2016-06-01       Impact factor: 3.039

7.  Coronary artery visibility in free-breathing young children on non-gated chest CT: impact of temporal resolution.

Authors:  Alexandre Bridoux; Antoine Hutt; Jean-Baptiste Faivre; Thomas Flohr; Alain Duhamel; Julien Pagniez; Jacques Remy; Martine Remy-Jardin
Journal:  Pediatr Radiol       Date:  2015-08-21

8.  High-pitch dual-source CT angiography without ECG-gating for imaging the whole aorta: intraindividual comparison with standard pitch single-source technique without ECG gating.

Authors:  Carmelinda Manna; Mario Silva; Rocco Cobelli; Sara Poggesi; Cristina Rossi; Nicola Sverzellati
Journal:  Diagn Interv Radiol       Date:  2017 Jul-Aug       Impact factor: 2.630

9.  Radiation dose and image quality of X-ray volume imaging systems: cone-beam computed tomography, digital subtraction angiography and digital fluoroscopy.

Authors:  Jijo Paul; Volkmar Jacobi; Mohammad Farhang; Babak Bazrafshan; Thomas J Vogl; Emmanuel C Mbalisike
Journal:  Eur Radiol       Date:  2012-12-19       Impact factor: 5.315

10.  Novel single-source high-pitch protocol for CT angiography of the aorta: comparison to high-pitch dual-source protocol in the context of TAVI planning.

Authors:  Bernhard Bischoff; Felix G Meinel; Maximilian Reiser; Hans-Christoph Becker
Journal:  Int J Cardiovasc Imaging       Date:  2013-01-19       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.