Literature DB >> 29808363

The feasibility of high-pitch acquisition protocol for imaging of the pediatric abdomen by dual-source CT.

Eray Atlı1,2, Erhan Akpınar3, Emre Ünal3, Berna Oğuz Sayan3, Mithat Haliloğlu3.   

Abstract

PURPOSE: To investigate feasibility of high-pitch acquisition protocol for imaging of pediatric abdomen.
MATERIALS AND METHODS: The study group consisted of 90 patients scanned with high-pitch acquisition protocol (pitch = 3) by 64-slice dual-source CT (DSCT) scanner. Fifty-four patients scanned with standard protocol (pitch = 1.5) by 16-slice single-source CT scanner comprised the control group. Anteroposterior and lateral diameters of abdomen, effective diameter, scan time and length, qualitative and quantitative noise levels, volumetric CT dose index (CTDIvol), dose length product (DLP), and size-specific dose estimations were compared between groups.
RESULTS: The mean scan time of high-pitch CT protocol was shorter than control protocol (1.66 ± 0.31 vs. 4.1 ± 0.75 s; p < 0.001). The high-pitch protocol reduced the radiation dose by 48% (CTDIvol and DLP values 0.94 mGy and 32.2 mGy-cm vs. 1.59 mGy and 61.5 mGy-cm; p < 0.001, respectively). Although image noise was higher with high-pitch acquisition, there was no significant effect on diagnostic confidence. Voluntary and involuntary artifacts were less frequent in high-pitch protocol (p < 0.001). Interobserver agreement was moderate in terms of artifact and very good in terms of diagnostic confidence assessment.
CONCLUSION: High-pitch acquisition protocol by DSCT yields significant radiation dose reduction without compromising image quality and diagnostic confidence for pediatric abdomen imaging.

Entities:  

Keywords:  Abdominal CT; Dual source; High pitch; Pediatrics; Radiation dose

Mesh:

Year:  2018        PMID: 29808363     DOI: 10.1007/s11604-018-0744-1

Source DB:  PubMed          Journal:  Jpn J Radiol        ISSN: 1867-1071            Impact factor:   2.374


  31 in total

Review 1.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

2.  Effects of adaptive section collimation on patient radiation dose in multisection spiral CT.

Authors:  Paul D Deak; Oliver Langner; Michael Lell; Willi A Kalender
Journal:  Radiology       Date:  2009-07       Impact factor: 11.105

3.  Medical radiation exposure in the U.S. in 2006: preliminary results.

Authors:  Fred A Mettler; Bruce R Thomadsen; Mythreyi Bhargavan; Debbie B Gilley; Joel E Gray; Jill A Lipoti; John McCrohan; Terry T Yoshizumi; Mahadevappa Mahesh
Journal:  Health Phys       Date:  2008-11       Impact factor: 1.316

4.  Accuracy and safety of high pitch computed tomography imaging in young children with complex congenital heart disease.

Authors:  B Kelly Han; Jana Lindberg; Katharine Grant; Robert S Schwartz; John R Lesser
Journal:  Am J Cardiol       Date:  2011-05-15       Impact factor: 2.778

5.  Optimization of kVp and mAs for pediatric low-dose simulated abdominal CT: is it best to base parameter selection on object circumference?

Authors:  Janet Reid; Jessica Gamberoni; Frank Dong; William Davros
Journal:  AJR Am J Roentgenol       Date:  2010-10       Impact factor: 3.959

6.  Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose).

Authors:  Holger Greess; Anton Nömayr; Heiko Wolf; Ulrich Baum; Michael Lell; Bernhard Böwing; Willi Kalender; Werner A Bautz
Journal:  Eur Radiol       Date:  2002-02-02       Impact factor: 5.315

7.  High-pitch dual-source CT angiography of the thoracic and abdominal aorta: is simultaneous coronary artery assessment possible?

Authors:  Robert Goetti; Stephan Baumüller; Gudrun Feuchtner; Paul Stolzmann; Christoph Karlo; Hatem Alkadhi; Sebastian Leschka
Journal:  AJR Am J Roentgenol       Date:  2010-04       Impact factor: 3.959

8.  Reducing abdominal CT radiation dose with the adaptive statistical iterative reconstruction technique in children: a feasibility study.

Authors:  Gregory A Vorona; Rafael C Ceschin; Barbara L Clayton; Tom Sutcavage; Sameh S Tadros; Ashok Panigrahy
Journal:  Pediatr Radiol       Date:  2011-05-19

9.  Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience.

Authors:  Sebastian Leschka; Paul Stolzmann; Lotus Desbiolles; Stephan Baumueller; Robert Goetti; Thomas Schertler; Hans Scheffel; Andre Plass; Volkmar Falk; Gudrun Feuchtner; Borut Marincek; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2009-09-16       Impact factor: 5.315

Review 10.  Technical principles of dual source CT.

Authors:  Martin Petersilka; Herbert Bruder; Bernhard Krauss; Karl Stierstorfer; Thomas G Flohr
Journal:  Eur J Radiol       Date:  2008-10-07       Impact factor: 3.528

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.