Novel single-source high-pitch protocol for CT angiography of the aorta: comparison to high-pitch dual-source protocol in the context of TAVI planning.

Bernhard Bischoff1, Felix G Meinel, Maximilian Reiser, Hans-Christoph Becker.   

Abstract

Purpose Computed tomography (CT) is increasingly being used for planning purposes prior to trans-arterial valve implantation (TAVI). High-pitch protocols using a 2nd generation dual-source CT (DSCT) allow for a comprehensive assessment of the aortic valve anulus, its distance to the coronary artery ostia, the aortic bulbus and the iliofemoral arteries with very low radiation exposure and low amount of contrast agent. The aim of this study was to evaluate the image quality of a comparable high-pitch scan mode in a modern single-source CT (SSCT) system. Methods 40 patients with severe symptomatic aortic valve stenosis have been examined for planning purposes prior to TAVI. The first 20 consecutive patients were examined with a 2nd generation DSCT system using a high-pitch scan mode (pitch value 3.4) and 60 ml of contrast agent. The second group of 20 consecutive patients were examined with a 128-slice SSCT system, using a high-pitch scan mode (pitch value of 1.7) and 60 ml of contrast agent. Image quality of the aortic valve, the ascending aorta, the coronary artery ostia, the iliofemoral arteries and overall image quality were graded in a blinded fashion using a 4-point-grading-scale. Furthermore, signal intensity and image noise were derived in the ascending aorta and in the ilio-femoral arteries. Results There was a minor but significant difference in the overall image quality score with lower image quality in SSCT (3.5 ± 0.6) when compared to DSCT (3.85 ± 0.4; p = 0.037). The mean image quality score was significantly higher in patients examined in DSCT when compared to SSCT regarding the evaluability of the coronary ostia (4.0 vs. 3.5; p < 0.01) and the image quality of the ascending aorta (4.0 vs. 3.5; p < 0.01). There was no significant difference in evaluation of the aortic valve and its anulus (3.85 for DSCT and 3.65 for SSCT; p = 0.149) and image quality of the iliofemoral arteries (3.65 for DSCT and 3.85 for SSCT; p = 0.140). Signal intensity and image noise did not differ significantly between both groups. Conclusions This study presents a novel high-pitch protocol for modern SSCT scanners, which allows CT angiography for TAVI planning with a similar radiation dose and contrast agent exposition and only small compromises in image quality compared to a high-pitch protocol on a DSCT scanner.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23334190     DOI: 10.1007/s10554-013-0182-1

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  16 in total

Review 1.  Multidetector computed tomography in transcatheter aortic valve implantation.

Authors:  Jonathon Leipsic; Ronen Gurvitch; Troy M Labounty; James K Min; David Wood; Mark Johnson; Amr M Ajlan; Namal Wijesinghe; John G Webb
Journal:  JACC Cardiovasc Imaging       Date:  2011-04

2.  Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis: the U.K. TAVI (United Kingdom Transcatheter Aortic Valve Implantation) Registry.

Authors:  Neil E Moat; Peter Ludman; Mark A de Belder; Ben Bridgewater; Andrew D Cunningham; Christopher P Young; Martyn Thomas; Jan Kovac; Tom Spyt; Philip A MacCarthy; Olaf Wendler; David Hildick-Smith; Simon W Davies; Uday Trivedi; Daniel J Blackman; Richard D Levy; Stephen J D Brecker; Andreas Baumbach; Tim Daniel; Huon Gray; Michael J Mullen
Journal:  J Am Coll Cardiol       Date:  2011-10-20       Impact factor: 24.094

3.  Accuracy and reproducibility of left ventricular outflow tract diameter measurement using transthoracic when compared with transesophageal echocardiography in systole and diastole.

Authors:  Avinoam Shiran; Salim Adawi; Majdi Ganaeem; Ehab Asmer
Journal:  Eur J Echocardiogr       Date:  2008-10-02

4.  Feasibility and accuracy of a comprehensive multidetector computed tomography acquisition for patients referred for balloon-expandable transcatheter aortic valve implantation.

Authors:  Gianluca Pontone; Daniele Andreini; Antonio L Bartorelli; Andrea Annoni; Saima Mushtaq; Erika Bertella; Alberto Formenti; Sarah Cortinovis; Francesco Alamanni; Melissa Fusari; Veronica Bona; Gloria Tamborini; Manuela Muratori; Giovanni Ballerini; Cesare Fiorentini; Paolo Biglioli; Mauro Pepi
Journal:  Am Heart J       Date:  2011-06       Impact factor: 4.749

5.  Dual source multidetector CT-angiography before Transcatheter Aortic Valve Implantation (TAVI) using a high-pitch spiral acquisition mode.

Authors:  W Wuest; K Anders; A Schuhbaeck; M S May; S Gauss; M Marwan; M Arnold; S Ensminger; G Muschiol; W G Daniel; M Uder; S Achenbach
Journal:  Eur Radiol       Date:  2011-08-17       Impact factor: 5.315

6.  Combined assessment of aortic root anatomy and aortoiliac vasculature with dual-source CT as a screening tool in patients evaluated for transcatheter aortic valve implantation.

Authors:  Philipp Blanke; Wulf Euringer; Tobias Baumann; Jochen Reinöhl; Christian Schlensak; Mathias Langer; Gregor Pache
Journal:  AJR Am J Roentgenol       Date:  2010-10       Impact factor: 3.959

7.  Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement.

Authors:  Laurens F Tops; David A Wood; Victoria Delgado; Joanne D Schuijf; John R Mayo; Sanjeevan Pasupati; Frouke P L Lamers; Ernst E van der Wall; Martin J Schalij; John G Webb; Jeroen J Bax
Journal:  JACC Cardiovasc Imaging       Date:  2008-05

8.  Prospective ECG-triggered, axial 4-D imaging of the aortic root, valvular, and left ventricular structures: a lower radiation dose option for preprocedural TAVR imaging.

Authors:  Michael A Bolen; Zoran B Popovic; Arun Dahiya; Samir R Kapadia; E Murat Tuzcu; Scott D Flamm; Sandra S Halliburton; Paul Schoenhagen
Journal:  J Cardiovasc Comput Tomogr       Date:  2012-11-03

9.  Inter-individual variance and cardiac cycle dependency of aortic root dimensions and shape as assessed by ECG-gated multi-slice computed tomography in patients with severe aortic stenosis prior to transcatheter aortic valve implantation: is it crucial for correct sizing?

Authors:  Lukas Lehmkuhl; Borek Foldyna; Konstantin Von Aspern; Christian Lücke; Matthias Grothoff; Stefan Nitzsche; Jörg Kempfert; Martin Haensig; Ardawan Rastan; Thomas Walther; Friedrich-Wilhelm Mohr; Matthias Gutberlet
Journal:  Int J Cardiovasc Imaging       Date:  2012-09-18       Impact factor: 2.357

10.  Benefits of high-pitch 128-slice dual-source computed tomography for planning of transcatheter aortic valve implantation.

Authors:  Fabian Plank; Guy Friedrich; Thomas Bartel; Silvana Mueller; Nikolaos Bonaros; Anneliese Heinz; Andrea Klauser; Fabiola Cartes-Zumelzu; Michael Grimm; Gudrun Feuchtner
Journal:  Ann Thorac Surg       Date:  2012-08-24       Impact factor: 4.330

View more
  4 in total

1.  Assessment of vascular contrast and wall motion of the aortic root and ascending aorta on MDCT angiography: dual-source high-pitch vs non-gated single-source acquisition schemes.

Authors:  Jared D Christensen; Danielle M Seaman; Matthew P Lungren; Lynne M Hurwitz; Daniel T Boll
Journal:  Eur Radiol       Date:  2014-02-28       Impact factor: 5.315

Review 2.  Cardiovascular imaging 2013 in the International Journal of Cardiovascular Imaging.

Authors:  Hiram G Bezerra; Ricardo A Costa; Johan H C Reiber; Frank J Rybicki; Paul Schoenhagen; Arthur A Stillman; Johan De Sutter; Nico R L Van de Veire
Journal:  Int J Cardiovasc Imaging       Date:  2014-04       Impact factor: 2.357

3.  High-pitch dual-source CT angiography without ECG-gating for imaging the whole aorta: intraindividual comparison with standard pitch single-source technique without ECG gating.

Authors:  Carmelinda Manna; Mario Silva; Rocco Cobelli; Sara Poggesi; Cristina Rossi; Nicola Sverzellati
Journal:  Diagn Interv Radiol       Date:  2017 Jul-Aug       Impact factor: 2.630

4.  320-row CT transcatheter aortic valve replacement planning with a single reduced contrast media bolus injection.

Authors:  Daddy Mata-Mbemba; Aissam Labani; Soraya El Ghannudi; Mi-Young Jeung; Patrick Ohlmann; Catherine Roy; Mickaël Ohana
Journal:  PLoS One       Date:  2018-09-13       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.