Literature DB >> 28555508

Iterative reconstruction in single-source dual-energy CT angiography: feasibility of low and ultra-low volume contrast medium protocols.

Ping Hou1, Xiangnan Feng2, Jie Liu1, Yue Zhou1, Yaojun Jiang1, Xiaochen Jiang1, Jianbo Gao1.   

Abstract

OBJECTIVE: To evaluate the feasibility of using contrast medium (CM) of low and ultra-low volumes and injection rates in aortic CT angiography (CTA) through the joint application of single-source dual-energy CT (ssDECT) and adaptive statistical iterative reconstruction (ASIR).
METHODS: 120 patients with known or suspected aortic dissection underwent aortic CTA and were equally divided into 3 groups. Conventional 120-kVp scan with a CM volume of 70 ml and an injection rate of 5 ml s-1 was performed on Group A. Groups B and C underwent ssDECT scan with CM volumes of 0.6 and 0.4 ml kg-1, respectively. 40% and 50% ASIR algorithms were applied for Groups B and C, respectively. A five-point grading scheme was utilized to subjectively evaluate the image quality, and the CT value and contrast-to-noise ratio were recorded as objective measures. The radiation dose was also evaluated.
RESULTS: Groups B and C had equivalent subjective scores and CT values as Group A, whereas they had higher or equivalent contrast-to-noise ratios. Group B had 40.1% and 30% reductions on CM volume and injection rate, respectively, than Group A. Group C further resulted in 19.2% and 22% lesser CM volume and injection rate than Group B. The average effective radiation doses for the study groups were 22.5-24.5% lower than the control group.
CONCLUSION: With the aid of ASIR and ssDECT for aortic CTA, it is feasible to adopt low and ultra-low CM volumes and injection rates while obtaining good quality images. Advances in knowledge: Low and ultra-low CM volumes and injection rates are feasible in CTA through the joint application of ssDECT and ASIR.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28555508      PMCID: PMC5594978          DOI: 10.1259/bjr.20160506

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  43 in total

Review 1.  Imaging of aortic dissection by helical computed tomography (CT).

Authors:  Serge Willoteaux; Christophe Lions; Virginia Gaxotte; Ziad Negaiwi; J P Beregi
Journal:  Eur Radiol       Date:  2004-08-05       Impact factor: 5.315

2.  Non-Electrocardiogram-Triggered 70-kVp High-Pitch Computed Tomography Angiography of the Whole Aorta With Iterative Reconstruction: Initial Results.

Authors:  Long Jiang Zhang; Xie Li; U Joseph Schoepf; Julian L Wichmann; Chun Xiang Tang; Chang Sheng Zhou; Guang Ming Lu
Journal:  J Comput Assist Tomogr       Date:  2016 Jan-Feb       Impact factor: 1.826

3.  Evaluation of an iterative model-based reconstruction algorithm for low-tube-voltage (80 kVp) computed tomography angiography.

Authors:  Peter B Noël; Thomas Köhler; Alexander A Fingerle; Kevin M Brown; Stanislav Zabic; Daniela Münzel; Bernhard Haller; Thomas Baum; Martin Henninger; Reinhard Meier; Ernst J Rummeny; Martin Dobritz
Journal:  J Med Imaging (Bellingham)       Date:  2014-10-09

4.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

5.  Use of non-linear image blending with dual-energy CT improves vascular visualization in abdominal angiography.

Authors:  P Lv; J Liu; R Wu; P Hou; L Hu; J Gao
Journal:  Clin Radiol       Date:  2013-11-26       Impact factor: 2.350

6.  Planimetry of the aortic valve orifice area: comparison of multislice spiral computed tomography and magnetic resonance imaging.

Authors:  Yvonne Westermann; Anja Geigenmüller; Thomas Elgeti; Moritz Wagner; Simon Dushe; Adrian C Borges; Pascal M Dohmen; Patrick A Hein; Alexander Lembcke
Journal:  Eur J Radiol       Date:  2009-09-23       Impact factor: 3.528

7.  Aortic dual-energy CT angiography with low contrast medium injection rate.

Authors:  Jie Liu; Pei-Jie Lv; Runze Wu; Yong-Gao Zhang; Li-Li Hu; Ping Hou; Jian-Bo Gao
Journal:  J Xray Sci Technol       Date:  2014       Impact factor: 1.535

8.  Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study.

Authors:  Sarabjeet Singh; Mannudeep K Kalra; Matthew D Gilman; Jiang Hsieh; Homer H Pien; Subba R Digumarthy; Jo-Anne O Shepard
Journal:  Radiology       Date:  2011-03-08       Impact factor: 11.105

9.  Contrast material-induced nephrotoxicity and intravenous low-osmolality iodinated contrast material: risk stratification by using estimated glomerular filtration rate.

Authors:  Matthew S Davenport; Shokoufeh Khalatbari; Richard H Cohan; Jonathan R Dillman; James D Myles; James H Ellis
Journal:  Radiology       Date:  2013-04-11       Impact factor: 11.105

10.  High-pitch, low-voltage and low-iodine-concentration CT angiography of aorta: assessment of image quality and radiation dose with iterative reconstruction.

Authors:  Yanguang Shen; Zhonghua Sun; Lei Xu; Yu Li; Nan Zhang; Zixu Yan; Zhanming Fan
Journal:  PLoS One       Date:  2015-02-02       Impact factor: 3.240

View more
  2 in total

Review 1.  Use of dual-energy CT for renal mass assessment.

Authors:  Shanigarn Thiravit; Christina Brunnquell; Larry M Cai; Mena Flemon; Achille Mileto
Journal:  Eur Radiol       Date:  2020-11-18       Impact factor: 5.315

2.  Automatic spectral imaging protocol and iterative reconstruction for radiation dose reduction in typical hepatic hemangioma computed tomography with reduced iodine load: a preliminary study.

Authors:  Wei Li; Aiyin Li; Bin Wang; Xiuyuan Niu; Xin Cao; Xinyi Wang; Hao Shi
Journal:  Br J Radiol       Date:  2018-05-17       Impact factor: 3.039

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.