Literature DB >> 21606297

Low-kilovoltage, high-tube-current MDCT of liver in thin adults: pilot study evaluating radiation dose, image quality, and display settings.

Takeshi Nakaura1, Kazuo Awai, Seitaro Oda, Yoshinori Funama, Kazunori Harada, Shouzaburou Uemura, Yasuyuki Yamashita.   

Abstract

OBJECTIVE: The purpose of our study was to evaluate the effect of a low tube voltage-high tube current-time product technique for portal phase abdominal CT of thin adults. SUBJECTS AND METHODS: This study included 25 patients who had undergone portal phase abdominal CT at 120 kVp in the preceding 6 months. All were scanned using 80 kVp and high tube-current time products. We assessed the estimated effective dose (ED), image noise, attenuation, contrast-to-noise ratio (CNR), and figure of merit of the liver and portal vein. Two radiologists evaluated the quality of scans for image contrast and streak artifacts at 80 kVp, 120 kVp, and 80 kVp with wide window width display presets (W-80).
RESULTS: The estimated ED was 33% lower at 80 than at 120 kVp. CNR of the portal vein was 36.8% higher at 80 than 120 kVp, and for the liver it was 17.7% higher at 80 than 120 kVp. The visual score of image contrast was significantly higher for W-80 than for 120 kVp; however, there was no significant difference in the visual score of streak artifacts.
CONCLUSION: At portal phase abdominal CT, 80 kVp and a high tube current-time product setting significantly improved image quality and reduced the radiation dose compared with 120 kVp.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21606297     DOI: 10.2214/AJR.10.5698

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  21 in total

Review 1.  Contrast medium administration and image acquisition parameters in renal CT angiography: what radiologists need to know.

Authors:  Charbel Saade; Ibrahim Alsheikh Deeb; Maha Mohamad; Hussain Al-Mohiy; Fadi El-Merhi
Journal:  Diagn Interv Radiol       Date:  2016 Mar-Apr       Impact factor: 2.630

2.  High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: initial experience.

Authors:  Martin Beeres; Boris Schell; Aristidis Mastragelopoulos; Eva Herrmann; Josef Matthias Kerl; Tatjana Gruber-Rouh; Clara Lee; Petra Siebenhandl; Boris Bodelle; Stephan Zangos; Thomas J Vogl; Volkmar Jacobi; Ralf W Bauer
Journal:  Eur Radiol       Date:  2011-09-14       Impact factor: 5.315

3.  Low radiation dose protocol in cardiac CT with 100 kVp: usefulness of display preset optimization.

Authors:  Takeshi Nakaura; Masafumi Kidoh; Naritsugu Sakaino; Shota Nakamura; Toshimitsu Nozaki; Akari Izumi; Kazunori Harada; Yasuyuki Yamashita
Journal:  Int J Cardiovasc Imaging       Date:  2013-04-09       Impact factor: 2.357

Review 4.  Considerations for Imaging the Inferior Vena Cava (IVC) with/without IVC Filters.

Authors:  Jessie Aw-Zoretic; Jeremy D Collins
Journal:  Semin Intervent Radiol       Date:  2016-06       Impact factor: 1.513

5.  Low-tube-voltage 80-kVp neck CT: evaluation of diagnostic accuracy and interobserver agreement.

Authors:  J L Wichmann; J Kraft; E-M Nöske; B Bodelle; I Burck; J-E Scholtz; C Frellesen; J Wagenblast; J M Kerl; R W Bauer; T Lehnert; T J Vogl; B Schulz
Journal:  AJNR Am J Neuroradiol       Date:  2014-08-07       Impact factor: 3.825

6.  Effect of various environments and computed tomography scanning parameters on renal volume measurements in vitro: A phantom study.

Authors:  Wangyan Liu; Yinsu Zhu; Lijun Tang; Xiaomei Zhu; Yi Xu; Guanyu Yang
Journal:  Exp Ther Med       Date:  2016-06-01       Impact factor: 2.447

7.  Advantages of 70-kV CT Angiography for the Visualization of the Adamkiewicz Artery: Comparison with 120-kV Imaging.

Authors:  S Shimoyama; T Nishii; Y Watanabe; A K Kono; K Kagawa; S Takahashi; K Sugimura
Journal:  AJNR Am J Neuroradiol       Date:  2017-09-14       Impact factor: 3.825

8.  Additive value of split-bolus single-phase CT scan protocol for preoperative assessment of lung cancer patients referred for video-assisted thoracic surgery.

Authors:  Ryo Watanabe; Yoshinori Funama; Takeshi Takaki; Seitaro Oda; Takeshi Nakaura; Seiichi Murakami; Takatoshi Aoki
Journal:  Radiol Phys Technol       Date:  2019-10-25

9.  Optimizing CT technique to reduce radiation dose: effect of changes in kVp, iterative reconstruction, and noise index on dose and noise in a human cadaver.

Authors:  Kevin J Chang; Scott Collins; Baojun Li; William W Mayo-Smith
Journal:  Radiol Phys Technol       Date:  2016-10-03

10.  Single-source dual-energy CT angiography with reduced iodine load in patients referred for aortoiliofemoral evaluation before transcatheter aortic valve implantation: impact on image quality and radiation dose.

Authors:  Benjamin Dubourg; Jérôme Caudron; Jean-Pierre Lestrat; Michael Bubenheim; Valentin Lefebvre; Matthieu Godin; Christophe Tron; Hélène Eltchaninoff; Fabrice Bauer; Jean-Nicolas Dacher
Journal:  Eur Radiol       Date:  2014-06-25       Impact factor: 5.315