Study of the Generalized MTF and DQE for a New Microangiographic System.

Iacovos S Kyprianou1, Stephen Rudin, Daniel R Bednarek, Kenneth R Hoffmann.   

Abstract

We study the properties of a new microangiographic system, consisting of a Region of Interest (ROI) microangiographic detector, x-ray source, and patient. The study was performed under conditions intended for clinical procedures such as neurological diagnostic angiograms as well as treatments of intracranial aneurysms, and vessel-stenoses. The study was performed in two steps; first a uniform head equivalent phantom was used as a "filter". This allowed us to study the properties of the detector alone, under clinically relevant x-ray spectra. We report the detector MTF, NPS, NEQ, and DQE for beam energies ranging from 60-100kVp and for different detector entrance exposures. For the second step, the phantom was placed adjacent to the detector, allowing scatter to enter the detector and new measurements were obtained for the same beam energies and detector entrance exposures. Different radiation field sizes were studied, and the effects of different scatter amounts were investigated. The spatial distribution of scatter was studied using the edge-spread method and a generalized system MTF was obtained by combining the scatter MTF weighted by the scatter fraction with the detector MTF and focal spot unsharpness due to magnification. The NPS combined with the generalized MTF gave the generalized system NEQ and DQE. The generalized NEQ and the ideal object detectability were used to calculate the Dose Area Product to the patient for 75% object detection probability. This was used as a system optimization method.

Entities:  

Year:  2004        PMID: 21603129      PMCID: PMC3097392          DOI: 10.1117/12.533512

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  19 in total

1.  An edge spread technique for measurement of the scatter-to-primary ratio in mammography.

Authors:  V N Cooper; J M Boone; J A Seibert; C J Pellot-Barakat
Journal:  Med Phys       Date:  2000-05       Impact factor: 4.071

2.  Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: characterization of a small area prototype detector.

Authors:  Wei Zhao; W G Ji; Anne Debrie; J A Rowlands
Journal:  Med Phys       Date:  2003-02       Impact factor: 4.071

3.  Micro-angiography for neuro-vascular imaging. II. Cascade model analysis.

Authors:  Arundhuti Ganguly; Stephen Rudin; Daniel R Bednarek; Kenneth R Hoffmann
Journal:  Med Phys       Date:  2003-11       Impact factor: 4.071

4.  Chest radiography: optimization of X-ray spectrum for cesium iodide-amorphous silicon flat-panel detector.

Authors:  James T Dobbins; Ehsan Samei; Harrell G Chotas; Richard J Warp; Alan H Baydush; Carey E Floyd; Carl E Ravin
Journal:  Radiology       Date:  2003-01       Impact factor: 11.105

5.  New device for accurate measurement of the x-ray intensity distribution of x-ray tube focal spots.

Authors:  K Doi; B Fromes; K Rossmann
Journal:  Med Phys       Date:  1975 Sep-Oct       Impact factor: 4.071

6.  A simple method for determining the modulation transfer function in digital radiography.

Authors:  H Fujita; D Y Tsai; T Itoh; K Doi; J Morishita; K Ueda; A Ohtsuka
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

7.  An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV.

Authors:  J M Boone; J A Seibert
Journal:  Med Phys       Date:  1997-11       Impact factor: 4.071

8.  Characterization of the point spread function and modulation transfer function of scattered radiation using a digital imaging system.

Authors:  J M Boone; B A Arnold; J A Seibert
Journal:  Med Phys       Date:  1986 Mar-Apr       Impact factor: 4.071

9.  DQE(f) of four generations of computed radiography acquisition devices.

Authors:  J T Dobbins; D L Ergun; L Rutz; D A Hinshaw; H Blume; D C Clark
Journal:  Med Phys       Date:  1995-10       Impact factor: 4.071

10.  Comparison of low contrast detectability between a digital amorphous silicon and a screen-film based imaging system for thoracic radiography.

Authors:  R Aufrichtig
Journal:  Med Phys       Date:  1999-07       Impact factor: 4.071

View more
  17 in total

1.  Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging.

Authors:  P Prakash; W Zbijewski; G J Gang; Y Ding; J W Stayman; J Yorkston; J A Carrino; J H Siewerdsen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  Singular value description of a digital radiographic detector: theory and measurements.

Authors:  Iacovos S Kyprianou; Aldo Badano; Brandon D Gallas; Kyle J Myers
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

3.  Quantitative comparison using Generalized Relative Object Detectability (G-ROD) metrics of an amorphous selenium detector with high resolution Microangiographic Fluoroscopes (MAF) and standard flat panel detectors (FPD).

Authors:  M Russ; A Shankar; A Jain; S V Setlur Nagesh; C N Ionita; C Scott; K S Karim; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-22

4.  Effective DQE (eDQE) and speed of digital radiographic systems: an experimental methodology.

Authors:  Ehsan Samei; Nicole T Ranger; Alistair MacKenzie; Ian D Honey; James T Dobbins; Carl E Ravin
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

5.  Evaluation of the microangiographic fluoroscope (MAF) using generalized system performance metrics.

Authors:  Amit Jain; Daniel R Bednarek; Stephen Rudin
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

6.  Intrinsic and total system performance evaluation for a newly developed Solid State X-ray Image Intensifier (SSXII) detector.

Authors:  V Singh; S N Swetadri Vasan; A Jain; P Sharma; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-03-06

7.  Evaluation and Comparison of High-Resolution (HR) and High-Light (HL) Phosphors in the Micro-Angiographic Fluoroscope (MAF) using Generalized Linear Systems Analyses (GMTF, GDQE) that include the Effect of Scatter, Magnification and Detector Characteristics.

Authors:  Sandesh K Gupta; Amit Jain; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2011

8.  Efficiency of the Human Observer Compared to an Ideal Observer Based on a Generalized NEQ Which Incorporates Scatter and Geometric Unsharpness: Evaluation with a 2AFC Experiment.

Authors:  Iacovos S Kyprianou; Arundhuti Ganguly; Stephen Rudin; Daniel R Bednarek; Brandon D Gallas; Kyle J Myers
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2005

9.  Overcoming x-ray tube small focal spot output limitations for high-resolution region of interest imaging.

Authors:  Sandesh K Gupta; Amit Jain; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-03-08

10.  Evaluation of intracranial aneurysm coil embolization in phantoms and patients using a high-resolution Microangiographic Fluoroscope (MAF).

Authors:  Ciprian N Ionita; Amit Jain; Brendan Loughran; Swetadri Vasan S N; Daniel R Bednarek; Elad Levy; Adnan H Siddiqui; Kenneth V Snyder; L N Hopkins; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-03-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.