Evaluation of the microangiographic fluoroscope (MAF) using generalized system performance metrics.

Amit Jain1, Daniel R Bednarek, Stephen Rudin.   

Abstract

PURPOSE: The performance of a newly developed, high resolution, microangiographic fluoroscope (MAF) (35 μm pixel pitch and 300 μm thick CsI phosphor) was evaluated using a generalized linear system analysis and compared with that of a standard amorphous Si thin film transistor flat panel detector (FPD) (194 μm pixel pitch and 600 μm thick CsI phosphor). The linear system metrics such as modulation transfer function (MTF), noise power spectrum, and detection quantum efficiency (DQE) are commonly used to gauge the intrinsic detector performance in the detector plane. However, these linear system metrics do not provide information about the image receptor performance in a real system since they do not include the effects of other parameters such as focal spot distribution, scatter radiation, and geometric unsharpness, which may compromise detector performance characteristics. Use of generalized linear system metrics [generalized modulation transfer function (GMTF), generalized normalized noise power spectrum (GNNPS), and generalized detection quantum efficiency (GDQE)] that include these effects gives a more meaningful, complete, and appropriate evaluation of detector performance as part of the imaging system.
METHODS: A uniform head equivalent phantom was used to simulate realistic clinical parameters and x-ray spectra. The detector MTFs were measured using the slanted edge method and the focal spot MTFs were measured using a pinhole assembly. The scatter MTF was simulated and the scatter fraction was measured for a head-equivalent phantom. The generalized system metrics were calculated for different combinations of three choices of focal spots and three different magnifications with two different air-gaps. The performance of the MAF was also illustrated using stent images obtained with different focal spots under similar conditions.
RESULTS: Results for the generalized metrics provide a quantitative description of the performance of the imaging system for both detectors. This generalized analysis demonstrated that both detectors have similar imaging capabilities at lower spatial frequencies, but that the MAF has superior performance over the FPD at higher frequencies even when considering focal spot blurring and scatter.
CONCLUSIONS: This generalized performance analysis demonstrates the significance of focal spot size, magnification, and scatter on the system performance metrics (GMTF, GNNPS, and GDQE). Although the ideal detector performance characteristics of the MAF are not fully realized due to these other system factors, it still retains an advantage in DQE at high spatial frequencies over the FPD. Similar studies based on the generalized linear system metrics can serve as an efficient tool to evaluate total system capabilities under different realistic conditions to enable optimal design for specific imaging tasks.

Entities:  

Mesh:

Year:  2013        PMID: 23464330      PMCID: PMC3598874          DOI: 10.1118/1.4792460

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  21 in total

1.  Evaluation of the imaging properties of an amorphous selenium-based flat panel detector for digital fluoroscopy.

Authors:  D C Hunt; O Tousignant; J A Rowlands
Journal:  Med Phys       Date:  2004-05       Impact factor: 4.071

2.  A simple method for determining the modulation transfer function in digital radiography.

Authors:  H Fujita; D Y Tsai; T Itoh; K Doi; J Morishita; K Ueda; A Ohtsuka
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

3.  Study of the Generalized MTF and DQE for a New Microangiographic System.

Authors:  Iacovos S Kyprianou; Stephen Rudin; Daniel R Bednarek; Kenneth R Hoffmann
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2004-05-06

4.  A method for measuring the presampled MTF of digital radiographic systems using an edge test device.

Authors:  E Samei; M J Flynn; D A Reimann
Journal:  Med Phys       Date:  1998-01       Impact factor: 4.071

5.  A new type of grid.

Authors:  I A Brezovich; G T Barnes
Journal:  Med Phys       Date:  1977 Sep-Oct       Impact factor: 4.071

6.  Endovascular coil embolization of a very small ruptured aneurysm using a novel microangiographic technique: technical note.

Authors:  Peter Kan; Parham Yashar; Ciprian N Ionita; Amit Jain; Stephen Rudin; Elad I Levy; Adnan H Siddiqui
Journal:  J Neurointerv Surg       Date:  2012-01-21       Impact factor: 5.836

7.  Design considerations for a new, high resolution Micro-Angiographic Fluoroscope based on a CMOS sensor (MAF-CMOS).

Authors:  Brendan Loughran; S N Swetadri Vasan; Vivek Singh; Ciprian N Ionita; Amit Jain; Daniel R Bednarek; Albert Titus; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-03-06

8.  Theoretical performance analysis for CMOS based high resolution detectors.

Authors:  Amit Jain; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-03-06

9.  Characterization of the point spread function and modulation transfer function of scattered radiation using a digital imaging system.

Authors:  J M Boone; B A Arnold; J A Seibert
Journal:  Med Phys       Date:  1986 Mar-Apr       Impact factor: 4.071

10.  DQE(f) of four generations of computed radiography acquisition devices.

Authors:  J T Dobbins; D L Ergun; L Rutz; D A Hinshaw; H Blume; D C Clark
Journal:  Med Phys       Date:  1995-10       Impact factor: 4.071

View more
  3 in total

1.  Region-of-interest cone beam computed tomography (ROI CBCT) with a high resolution CMOS detector.

Authors:  A Jain; H Takemoto; M D Silver; S V S Nagesh; C N Ionita; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-18

2.  Photon-counting hexagonal pixel array CdTe detector: Spatial resolution characteristics for image-guided interventional applications.

Authors:  Srinivasan Vedantham; Suman Shrestha; Andrew Karellas; Linxi Shi; Matthew J Gounis; Ronaldo Bellazzini; Gloria Spandre; Alessandro Brez; Massimo Minuti
Journal:  Med Phys       Date:  2016-05       Impact factor: 4.071

3.  Initial investigations of a special high-definition (Hi-Def) zoom capability in a new detector system for neuro-interventional procedures.

Authors:  S V Setlur Nagesh; A Shankar; J Krebs; J Hinaman; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-09
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.