DQE(f) of four generations of computed radiography acquisition devices.

J T Dobbins1, D L Ergun, L Rutz, D A Hinshaw, H Blume, D C Clark.   

Abstract

Measurements were made of the MTF(f), NPS(f), and DQE(f) of four generations of computed radiography (CR) imaging plates and three generations of CR image readers. The MTF generally showed only a minor change between generations of plates and readers, but the DQE(f) has improved substantially from a very early plate/reader combination to a more recent one. The DQE in the more recent plate/reader combination is 1.3X greater at low frequencies and about 3X greater at high frequencies than the much earlier versions. Thus there has been substantial improvement in the imaging performance obtainable with CR since some of the early observer studies which indicated poorer performance with CR than with screen-film.

Entities:  

Mesh:

Year:  1995        PMID: 8551982     DOI: 10.1118/1.597627

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  46 in total

1.  Full breast digital mammography with an amorphous silicon-based flat panel detector: physical characteristics of a clinical prototype.

Authors:  S Vedantham; A Karellas; S Suryanarayanan; D Albagli; S Han; E J Tkaczyk; C E Landberg; B Opsahl-Ong; P R Granfors; I Levis; C J D'Orsi; R E Hendrick
Journal:  Med Phys       Date:  2000-03       Impact factor: 4.071

2.  A new needle-crystalline computed radiography detector.

Authors:  P Leblans; L Struye; P Willems
Journal:  J Digit Imaging       Date:  2000-05       Impact factor: 4.056

3.  Mammographic imaging with a small format CCD-based digital cassette: physical characteristics of a clinical system.

Authors:  S Vedantham; A Karellas; S Suryanarayanan; I Levis; M Sayag; R Kleehammer; R Heidsieck; C J D'Orsi
Journal:  Med Phys       Date:  2000-08       Impact factor: 4.071

4.  Comparison of visual grading analysis and determination of detective quantum efficiency for evaluating system performance in digital chest radiography.

Authors:  Patrik Sund; Magnus Båth; Susanne Kheddache; Lars Gunnar Månsson
Journal:  Eur Radiol       Date:  2003-10-16       Impact factor: 5.315

5.  Solid-state fluoroscopic imager for high-resolution angiography: parallel-cascaded linear systems analysis.

Authors:  Srinivasan Vedantham; Andrew Karellas; Sankararaman Suryanarayanan
Journal:  Med Phys       Date:  2004-05       Impact factor: 4.071

6.  Solid-state fluoroscopic imager for high-resolution angiography: physical characteristics of an 8 cm x 8 cm experimental prototype.

Authors:  Srinivasan Vedantham; Andrew Karellas; Sankararaman Suryanarayanan; Steven K Onishi
Journal:  Med Phys       Date:  2004-06       Impact factor: 4.071

7.  Emerging Breast Imaging Technologies on the Horizon.

Authors:  Srinivasan Vedantham; Andrew Karellas
Journal:  Semin Ultrasound CT MR       Date:  2017-09-13       Impact factor: 1.875

8.  Flat detectors and their clinical applications.

Authors:  Martin Spahn
Journal:  Eur Radiol       Date:  2005-04-02       Impact factor: 5.315

9.  A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis.

Authors:  Yiheng Zhang; Heang-Ping Chan; Berkman Sahiner; Jun Wei; Mitchell M Goodsitt; Lubomir M Hadjiiski; Jun Ge; Chuan Zhou
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

10.  The effect of averaging adjacent planes for artifact reduction in matrix inversion tomosynthesis.

Authors:  Devon J Godfrey; H Page McAdams; James T Dobbins
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.