Literature DB >> 10841386

An edge spread technique for measurement of the scatter-to-primary ratio in mammography.

V N Cooper1, J M Boone, J A Seibert, C J Pellot-Barakat.   

Abstract

An experimental measurement technique that directly measures the magnitude and spatial distribution of scatter in relation to primary radiation is presented in this work. The technique involves the acquisition of magnified edge spread function (ESF) images with and without scattering material present. The ESFs are normalized and subtracted to yield scatter-to-primary ratios (SPRs), along with the spatial distributions of scatter and primary radiation. Mammography is used as the modality to demonstrate the ESF method, which is applicable to all radiographic environments. Sets of three images were acquired with a modified clinical mammography system employing a flat panel detector for 2, 4, 6, and 8 cm thick breast tissue equivalent material phantoms composed of 0%, 43%, and 100% glandular tissue at four different kV settings. Beam stop measurements of scatter were used to validate the ESF methodology. There was good agreement of the mean SPRs between the beam stop and ESF methods. There was good precision in the ESF-determined SPRs with a coefficient of variation on the order of 5%. SPRs ranged from 0.2 to 2.0 and were effectively independent of energy for clinically realistic kVps. The measured SPRs for 2, 4, and 6 cm 0% glandular phantoms imaged at 28 kV were 0.21+/-0.01, 0.39+/-0.01, and 0.57+/-0.02, respectively. The measured SPRs for 2, 4, and 6 cm 43% glandular phantoms imaged at 28 kV were 0.20+/-0.01, 0.35+/-0.02, and 0.53+/-0.02, respectively. The measured SPRs for 2, 4, and 6 cm 100% glandular phantoms imaged at 28 kV were 0.22+/-0.02, 0.42+/-0.03, and 0.88+/-0.08, respectively.

Mesh:

Year:  2000        PMID: 10841386     DOI: 10.1118/1.598950

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  Scatter radiation in digital tomosynthesis of the breast.

Authors:  Ioannis Sechopoulos; Sankararaman Suryanarayanan; Srinivasan Vedantham; Carl J D'Orsi; Andrew Karellas
Journal:  Med Phys       Date:  2007-02       Impact factor: 4.071

2.  Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): simulation with spot images.

Authors:  Xinming Liu; Chris C Shaw
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

3.  Scatter rejection and low-contrast performance of a slot-scan digital chest radiography system with electronic aft-collimation: a chest phantom study.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Mustafa C Altunbas; Lingyun Chen; Tao Han; Tianpeng Wang
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

4.  Study of the Generalized MTF and DQE for a New Microangiographic System.

Authors:  Iacovos S Kyprianou; Stephen Rudin; Daniel R Bednarek; Kenneth R Hoffmann
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2004-05-06

5.  Impact of flat panel-imager veiling glare on scatter-estimation accuracy and image quality of a commercial on-board cone-beam CT imaging system.

Authors:  Dimitrios Lazos; Jeffrey F Williamson
Journal:  Med Phys       Date:  2012-09       Impact factor: 4.071

6.  Intrinsic and total system performance evaluation for a newly developed Solid State X-ray Image Intensifier (SSXII) detector.

Authors:  V Singh; S N Swetadri Vasan; A Jain; P Sharma; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-03-06

7.  Efficiency of the Human Observer Compared to an Ideal Observer Based on a Generalized NEQ Which Incorporates Scatter and Geometric Unsharpness: Evaluation with a 2AFC Experiment.

Authors:  Iacovos S Kyprianou; Arundhuti Ganguly; Stephen Rudin; Daniel R Bednarek; Brandon D Gallas; Kyle J Myers
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2005

8.  Generalized Performance Evaluation of X-ray Image Intensifier compared with a Microangiographic System.

Authors:  Girijesh K Yadava; Iacovos S Kyprianou; Stephen Rudin; Daniel R Bednarek; Kenneth R Hoffmann
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2005

9.  Scan equalization digital radiography (SEDR) implemented with an amorphous selenium flat-panel detector: initial experience.

Authors:  Xinming Liu; Chao-Jen Lai; Lingyun Chen; Tao Han; Yuncheng Zhong; Youtao Shen; Tianpeng Wang; Chris C Shaw
Journal:  Phys Med Biol       Date:  2009-11-04       Impact factor: 3.609

10.  Quantification of breast arterial calcification using full field digital mammography.

Authors:  Sabee Molloi; Tong Xu; Justin Ducote; Carlos Iribarren
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.