Literature DB >> 10435537

Comparison of low contrast detectability between a digital amorphous silicon and a screen-film based imaging system for thoracic radiography.

R Aufrichtig1.   

Abstract

Low contrast threshold detectability is investigated theoretically and experimentally for an amorphous silicon (a-Si) x-ray detector designed for digital radiography and for a standard thoracic screen-film combination. A theoretical signal-to-noise ratio is described with a human observer signal detection model. It is calculated using the detective quantum efficiency (DQE) and the modulation transfer function of the imaging system, as well as a spatial response function for the human visual system. Using a four-alternative forced choice observer perception study, the threshold contrasts of disk shaped objects ranging in size from 0.3 to 4.0 mm are determined. Significantly better contrast detectability is obtained from the digital detector, which is attributed to its higher DQE. On average, the disk shaped objects can be detected at 45% less contrast than required for screen-film. With no free parameters the experimental data agree well with those predicted by the observer model. Based upon the data, the model predicts that x-ray exposure for the a-Si detector only needs to be 30% of the exposure required to perform equally well on the contrast-detail detectability task using screen-film.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10435537     DOI: 10.1118/1.598630

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  12 in total

1.  Clinical results of CsI-detector-based dual-exposure dual energy in chest radiography.

Authors:  Jens Ricke; Frank Fischbach; Torsten Freund; Ulf Teichgräber; Enrique Lopez Hänninen; Rainer Röttgen; Ulrike Engert; Hermann Eichstädt; Roland Felix
Journal:  Eur Radiol       Date:  2003-06-19       Impact factor: 5.315

2.  A perceptual evaluation of JPEG 2000 image compression for digital mammography: contrast-detail characteristics.

Authors:  Sankararaman Suryanarayanan; Andrew Karellas; Srinivasan Vedantham; Sandra M Waldrop; Carl J D'Orsi
Journal:  J Digit Imaging       Date:  2004-03       Impact factor: 4.056

3.  Contrast-detail evaluation and dose assessment of eight digital chest radiography systems in clinical practice.

Authors:  Wouter J H Veldkamp; Lucia J M Kroft; Mireille V Boot; Bart J A Mertens; Jacob Geleijns
Journal:  Eur Radiol       Date:  2005-08-31       Impact factor: 5.315

4.  Should 3K zoom function be used for detection of pneumothorax in cesium iodide/amorphous silicon flat-panel detector radiographs presented on 1K-matrix soft copies?

Authors:  Karin A Herrmann; H M Bonél; A Stäbler; M Voelk; M Strotzer; C J Zech; M F Reiser
Journal:  Eur Radiol       Date:  2006-08-01       Impact factor: 5.315

5.  Detection of simulated microcalcifications in a phantom with digital mammography: effect of pixel size.

Authors:  Sankararaman Suryanarayanan; Andrew Karellas; Srinivasan Vedantham; Ioannis Sechopoulos; Carl J D'Orsi
Journal:  Radiology       Date:  2007-05-23       Impact factor: 11.105

6.  Reduction of radiation dose for cerebral angiography using flat panel detector of direct conversion type: a vascular phantom study.

Authors:  Y Hatakeyama; S Kakeda; N Ohnari; J Moriya; N Oda; K Nishino; W Miyamoto; Y Korogi
Journal:  AJNR Am J Neuroradiol       Date:  2007-04       Impact factor: 3.825

7.  Digital magnification mammography with matched incident exposure: physical imaging properties and detectability of simulated microcalcifications.

Authors:  Nobukazu Tanaka; Kentaro Naka; Hiroko Fukushima; Junji Morishita; Fukai Toyofuku; Masafumi Ohki; Yoshiharu Higashida
Journal:  Radiol Phys Technol       Date:  2011-03-18

8.  Study of the Generalized MTF and DQE for a New Microangiographic System.

Authors:  Iacovos S Kyprianou; Stephen Rudin; Daniel R Bednarek; Kenneth R Hoffmann
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2004-05-06

9.  Basic imaging properties of an indirect flat-panel detector system employing irradiation side sampling (ISS) technology for chest radiography: comparison with a computed radiographic system.

Authors:  Nobukazu Tanaka; Yuki Yano; Hidetake Yabuuchi; Tsutomu Akasaka; Masayuki Sasaki; Masafumi Ohki; Junji Morishita
Journal:  Radiol Phys Technol       Date:  2012-11-10

10.  Investigation of optimum anti-scatter grid selection for digital radiography: physical imaging properties and detectability of low-contrast signals.

Authors:  Nobukazu Tanaka; Kentaro Naka; Aya Saito; Junji Morishita; Fukai Toyofuku; Masafumi Ohki; Yoshiharu Higashida
Journal:  Radiol Phys Technol       Date:  2012-08-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.