Evaluation and Comparison of High-Resolution (HR) and High-Light (HL) Phosphors in the Micro-Angiographic Fluoroscope (MAF) using Generalized Linear Systems Analyses (GMTF, GDQE) that include the Effect of Scatter, Magnification and Detector Characteristics.

Sandesh K Gupta1, Amit Jain, Daniel R Bednarek, Stephen Rudin.   

Abstract

In this study, we evaluated the imaging characteristics of the high-resolution, high-sensitivity micro-angiographic fluoroscope (MAF) with 35-micron pixel-pitch when used with different commercially-available 300 micron thick phosphors: the high resolution (HR) and high light (HL) from Hamamatsu. The purpose of this evaluation was to see if the HL phosphor with its higher screen efficiency could be replaced with the HR phosphor to achieve improved resolution without an increase in noise resulting from the HR's decreased light-photon yield. We designated the detectors MAF-HR and MAF-HL and compared them with a standard flat panel detector (FPD) (194 micron pixel pitch and 600 micron thick CsI(Tl)). For this comparison, we used the generalized linear-system metrics of GMTF, GNNPS and GDQE which are more realistic measures of total system performance since they include the effect of scattered radiation, focal spot distribution, and geometric un-sharpness. Magnifications (1.05-1.15) and scatter fractions (0.28 and 0.33) characteristic of a standard head phantom were used. The MAF-HR performed significantly better than the MAF-HL at high spatial frequencies. The ratio of GMTF and GDQE of the MAF-HR compared to the MAF-HL at 3(6) cycles/mm was 1.45(2.42) and 1.23(2.89), respectively. Despite significant degradation by inclusion of scatter and object magnification, both MAF-HR and MAF-HL provide superior performance over the FPD at higher spatial frequencies with similar performance up to the FPD's Nyquist frequency of 2.5 cycles/mm. Both substantially higher resolution and improved GDQE can be achieved with the MAF using the HR phosphor instead of the HL phosphor.

Entities:  

Year:  2011        PMID: 21760698      PMCID: PMC3134255          DOI: 10.1117/12.877714

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  17 in total

1.  Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: characterization of a small area prototype detector.

Authors:  Wei Zhao; W G Ji; Anne Debrie; J A Rowlands
Journal:  Med Phys       Date:  2003-02       Impact factor: 4.071

2.  Micro-angiography for neuro-vascular imaging. II. Cascade model analysis.

Authors:  Arundhuti Ganguly; Stephen Rudin; Daniel R Bednarek; Kenneth R Hoffmann
Journal:  Med Phys       Date:  2003-11       Impact factor: 4.071

3.  New device for accurate measurement of the x-ray intensity distribution of x-ray tube focal spots.

Authors:  K Doi; B Fromes; K Rossmann
Journal:  Med Phys       Date:  1975 Sep-Oct       Impact factor: 4.071

4.  Study of the Generalized MTF and DQE for a New Microangiographic System.

Authors:  Iacovos S Kyprianou; Stephen Rudin; Daniel R Bednarek; Kenneth R Hoffmann
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2004-05-06

5.  A method for measuring the presampled MTF of digital radiographic systems using an edge test device.

Authors:  E Samei; M J Flynn; D A Reimann
Journal:  Med Phys       Date:  1998-01       Impact factor: 4.071

6.  A new type of grid.

Authors:  I A Brezovich; G T Barnes
Journal:  Med Phys       Date:  1977 Sep-Oct       Impact factor: 4.071

7.  Characterization of the point spread function and modulation transfer function of scattered radiation using a digital imaging system.

Authors:  J M Boone; B A Arnold; J A Seibert
Journal:  Med Phys       Date:  1986 Mar-Apr       Impact factor: 4.071

8.  DQE(f) of four generations of computed radiography acquisition devices.

Authors:  J T Dobbins; D L Ergun; L Rutz; D A Hinshaw; H Blume; D C Clark
Journal:  Med Phys       Date:  1995-10       Impact factor: 4.071

9.  Generalized two-dimensional (2D) linear system analysis metrics (GMTF, GDQE) for digital radiography systems including the effect of focal spot, magnification, scatter, and detector characteristics.

Authors:  Amit Jain; Andrew T Kuhls-Gilcrist; Sandesh K Gupta; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2010-03-01

10.  X-ray imaging performance of structured cesium iodide scintillators.

Authors:  Wei Zhao; Goran Ristic; J A Rowlands
Journal:  Med Phys       Date:  2004-09       Impact factor: 4.071

View more
  1 in total

1.  Overcoming x-ray tube small focal spot output limitations for high-resolution region of interest imaging.

Authors:  Sandesh K Gupta; Amit Jain; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-03-08
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.