Literature DB >> 21079952

Excellent results with cementless total hip arthroplasty and alumina-on-alumina pairing: minimum ten-year follow-up.

Alexander M Kress1, Rainer Schmidt, Ulrich Holzwarth, Raimund Forst, Lutz A Mueller.   

Abstract

Ceramic-on-ceramic coupling is thought to be a durable alternative to metal- or alumina-on-polyethylene pairing. No evidence exists suggesting superior clinical and radiological results for hydroxyapatite-coated stems versus uncoated stems. The aim of this study is to report the performance of an alumina-on-alumina bearing cementless total hip arthroplasty and to compare stems with a tapered design with and without hydroxyapatite coating. We prospectively analysed the results of cementless tapered femoral stems (40 hydroxyapatite-coated versus 22 uncoated stems), a metal-backed fibre mesh hydroxyapatite-coated socket and alumina-on-alumina pairing. Of 75 hips studied, 62 were available for follow-up (mean of 10.5 years after surgery). The average Harris hip score was 90. Only one hydroxyapatite-coated stem was revised for aseptic loosening. One instance of non-progressive osteolysis was detected around a screw of a cup. All other components showed radiographic signs of stable ingrowth. Hydroxyapatite coating of the stem had no significant impact on the clinical or radiological results. Total hip arthroplasty with the presented implant and pairing provides a durable standard for all patients requiring hip joint replacement against which all newer generations of cementless implants should be judged.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21079952      PMCID: PMC3032123          DOI: 10.1007/s00264-010-1150-1

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  28 in total

Review 1.  Evolution of alumina-on-alumina implants: a review.

Authors:  L Sedel
Journal:  Clin Orthop Relat Res       Date:  2000-10       Impact factor: 4.176

2.  The performance of two hydroxyapatite-coated acetabular cups compared with Charnley cups. From the Norwegian Arthroplasty Register.

Authors:  L I Havelin; B Espehaug; L B Engesaeter
Journal:  J Bone Joint Surg Br       Date:  2002-08

3.  Comparison of wear and osteolysis in hip replacement using two different coatings of the femoral stem.

Authors:  Joaquin Sanchez-Sotelo; David G Lewallen; William Scott Harmsen; Jeffrey Harrington; Miguel E Cabanela
Journal:  Int Orthop       Date:  2004-04-29       Impact factor: 3.075

4.  Prospective matched-pair analysis of hydroxyapatite-coated and uncoated femoral stems in total hip arthroplasty. A concise follow-up of a previous report.

Authors:  Javad Parvizi; Peter F Sharkey; William J Hozack; Fabio Orzoco; Gina A Bissett; Richard H Rothman
Journal:  J Bone Joint Surg Am       Date:  2004-04       Impact factor: 5.284

5.  Radiological demarcation of cemented sockets in total hip replacement.

Authors:  J G DeLee; J Charnley
Journal:  Clin Orthop Relat Res       Date:  1976 Nov-Dec       Impact factor: 4.176

6.  The anatomic basis of femoral component design.

Authors:  P C Noble; J W Alexander; L J Lindahl; D T Yew; W M Granberry; H S Tullos
Journal:  Clin Orthop Relat Res       Date:  1988-10       Impact factor: 4.176

7.  Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results.

Authors:  C A Engh; J D Bobyn; A H Glassman
Journal:  J Bone Joint Surg Br       Date:  1987-01

8.  [Personal experiences with uncemented prostheses].

Authors:  L Spotorno; R K Schenk; C Dietschi; S Romagnoli; A Mumenthaler
Journal:  Orthopade       Date:  1987-06       Impact factor: 1.087

9.  The Bicontact cementless primary total hip arthroplasty: long-term results.

Authors:  Girish Swamy; Alistair Pace; Conal Quah; Peter Howard
Journal:  Int Orthop       Date:  2010-09-10       Impact factor: 3.075

10.  Excellent results of HA coating on a grit-blasted stem: 245 patients followed for 8-12 years.

Authors:  Olav Reikerås; Ragnhild B Gunderson
Journal:  Acta Orthop Scand       Date:  2003-04
View more
  15 in total

1.  Fractures of a sandwich ceramic liner at ten year follow-up.

Authors:  Anthony Viste; Julien Chouteau; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2011-10-20       Impact factor: 3.075

2.  Total Hip Arthroplasty, state of the art for the 21st century.

Authors:  Jean-Pierre Courpied; Jacques Henri Caton
Journal:  Int Orthop       Date:  2011-01-18       Impact factor: 3.075

3.  A cementless hip system with a new surface for osseous integration.

Authors:  Richard Lass; Alexander Kolb; Gobert Skrbensky; Georg Reinisch; Bernd Kubista; Alexander Giurea; Reinhard Windhager; Rainer Kotz
Journal:  Int Orthop       Date:  2013-10-11       Impact factor: 3.075

4.  Ceramic bearings with bilayer coating in cementless total hip arthroplasty. A safe solution. A retrospective study of one hundred and twenty six cases with more than ten years' follow-up.

Authors:  André Ferreira; Thierry Aslanian; Thibaud Dalin; Jean Picaud
Journal:  Int Orthop       Date:  2016-08-20       Impact factor: 3.075

5.  Alumina-on-alumina THA performed in patients younger than 30 years: a 10-year minimum followup study.

Authors:  Hyeong Jo Yoon; Jeong Joon Yoo; Kang Sup Yoon; Kyung-Hoi Koo; Hee Joong Kim
Journal:  Clin Orthop Relat Res       Date:  2012-07-24       Impact factor: 4.176

6.  Ceramic bearings for total hip arthroplasty have high survivorship at 10 years.

Authors:  James A D'Antonio; William N Capello; Marybeth Naughton
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

Review 7.  Thirty years of experience with alumina-on-alumina bearings in total hip arthroplasty.

Authors:  Didier Hannouche; Amine Zaoui; Frédéric Zadegan; Laurent Sedel; Rémy Nizard
Journal:  Int Orthop       Date:  2010-12-30       Impact factor: 3.075

8.  In vivo testing of canine prosthetic femoral components with HA-Ti ladder-type coating on vacuum plasma-sprayed Ti substrate.

Authors:  Xian-Lin Zeng; Jing-Feng Li; Shu-Hua Yang; Qi-Xin Zheng; Zhen-Wei Zou
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2013-08-01

9.  A randomised prospective evaluation of ceramic-on-ceramic and ceramic-on-highly cross-linked polyethylene bearings in the same patients with primary cementless total hip arthroplasty.

Authors:  Young-Hoo Kim; Jang-Won Park; Sourabh S Kulkarni; Yoon-Hong Kim
Journal:  Int Orthop       Date:  2013-08-03       Impact factor: 3.075

10.  Behaviour of the ultra-short anatomic cementless femoral stem in young and elderly patients.

Authors:  Young-Hoo Kim; Jang-Won Park; Jun-Shik Kim
Journal:  Int Orthop       Date:  2013-08-08       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.