PURPOSE: The failure of total hip systems caused by wear-particle-induced loosening has focused interest on factors potentially affecting wear rate. Remnants of the blasting material were reported on grit-blasted surfaces for cementless fixation. These particles are believed to cause third-body wear and implant loosening. The purpose of this study was to evaluate the early clinical and radiological outcomes of a cementless hip system with a new, contamination-free, roughened surface with regard to prosthesis-related failures. METHODS: Between May 2004 and March 2009, 202 consecutive primary total hip arthroplasties (THAs) (192 patients with a mean age of 62.6 years) were performed using a cementless stem (Hipstar®) and a hemispherical acetabular cup (Trident®). RESULTS: At a minimum follow-up of two years, five revisions (2.5%) due to aseptic loosening of the stem and three (1.5%) of the cup were necessary. The cumulative rate of prostheses survival, counting revision of both components and with aseptic failure as end point, was 92.9% at 8.8 years. Radiolucent lines up to three millimetres were evaluated in the proximal part of the femur in 61% of cases. CONCLUSIONS: Although the incidence of radiolucent lines was decreased, the revision rate was considerably increased compared to other uncemented hip implants with grit-blasted surfaces in the short- to mid-term follow-up of our study. Subsequent studies are needed to confirm whether these changes in implant material and surface affect the radiological and clinical outcome in the long term.
PURPOSE: The failure of total hip systems caused by wear-particle-induced loosening has focused interest on factors potentially affecting wear rate. Remnants of the blasting material were reported on grit-blasted surfaces for cementless fixation. These particles are believed to cause third-body wear and implant loosening. The purpose of this study was to evaluate the early clinical and radiological outcomes of a cementless hip system with a new, contamination-free, roughened surface with regard to prosthesis-related failures. METHODS: Between May 2004 and March 2009, 202 consecutive primary total hip arthroplasties (THAs) (192 patients with a mean age of 62.6 years) were performed using a cementless stem (Hipstar®) and a hemispherical acetabular cup (Trident®). RESULTS: At a minimum follow-up of two years, five revisions (2.5%) due to aseptic loosening of the stem and three (1.5%) of the cup were necessary. The cumulative rate of prostheses survival, counting revision of both components and with aseptic failure as end point, was 92.9% at 8.8 years. Radiolucent lines up to three millimetres were evaluated in the proximal part of the femur in 61% of cases. CONCLUSIONS: Although the incidence of radiolucent lines was decreased, the revision rate was considerably increased compared to other uncemented hip implants with grit-blasted surfaces in the short- to mid-term follow-up of our study. Subsequent studies are needed to confirm whether these changes in implant material and surface affect the radiological and clinical outcome in the long term.
Authors: Craig J Della Valle; Nathan W Mesko; Laura Quigley; Aaron G Rosenberg; Joshua J Jacobs; Jorge O Galante Journal: J Bone Joint Surg Am Date: 2009-05 Impact factor: 5.284
Authors: Alexander Kolb; Alexander Grübl; Charlotte-Dorothé Schneckener; Catharina Chiari; Alexandra Kaider; Richard Lass; Reinhard Windhager Journal: J Bone Joint Surg Am Date: 2012-09-19 Impact factor: 5.284
Authors: Rob Zwartele; Anil Peters; Johannes Brouwers; Paul Olsthoorn; Ronald Brand; Cornelis Doets Journal: Int Orthop Date: 2007-07-03 Impact factor: 3.075
Authors: Steffen Brodt; Georg Matziolis; Christoph Windisch; Andreas Gosse; Matthias Spalteholz; Ralf Herbert Gahr Journal: Int Orthop Date: 2015-07-08 Impact factor: 3.075