Literature DB >> 23904375

In vivo testing of canine prosthetic femoral components with HA-Ti ladder-type coating on vacuum plasma-sprayed Ti substrate.

Xian-Lin Zeng1, Jing-Feng Li2,3, Shu-Hua Yang2, Qi-Xin Zheng2, Zhen-Wei Zou2.   

Abstract

The purpose of the present study was to observe the structure and functional change of the bone-coating-prosthesis interface in vivo and to evaluate the histocompatibility of self-made prosthetic femoral components in the body and the degree of their bonding with the surrounding bone tissues as well as their stability. Six mature beagle dogs underwent bilateral hip replacement with prosthetic femur components. Three groups were established in terms of different coating of prothesis (four joints in each group): atmosphere (A) plasma-sprayed pure titanium (Ti) prosthetic joint with hydroxyapatite (HA) coating (HA+Ti+A group); vacuum (V) plasma-sprayed pure Ti prosthetic joint with HA coating (HA+Ti+V group); vacuum plasma-sprayed pure Ti prosthetic joint with Ti-HA stepped coating (Ti+HAG+Ti+V group). The hip joints were functionally evaluated, and subjected to X-ray examination, biomechanics inspection, and histological examination. As a result, X-ray imaging revealed all prosthetic joints were in a good location and no dislocation of joint was found. Shear strength of interface was significantly higher in Ti+HAG+Ti+V group than in HA+Ti+V group (P<0.05) and HA+Ti+A group (P<0.05) at 28th week. Histological examination showed the amount of newborn bone in Ti+HAG+Ti+V group was more than in HA+Ti+V group and HA+Ti+A group after 28 weeks. It was suggested that vacuum plasma-sprayed pure Ti prosthetic joint with TI-HA stepped coating could improve the bonding capacity of bone-prosthesis, enhance the stability of prosthesis, and increase the fixion of prosthetic femoral components because of better bone growth. This new type of biological material in prosthetic femoral components holds promises for application in clinical practice.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23904375     DOI: 10.1007/s11596-013-1156-1

Source DB:  PubMed          Journal:  J Huazhong Univ Sci Technolog Med Sci        ISSN: 1672-0733


  39 in total

Review 1.  Prosthetic joint infection: recent developments in diagnosis and management.

Authors:  Maria Adriana Cataldo; Nicola Petrosillo; Michela Cipriani; Roberto Cauda; Evelina Tacconelli
Journal:  J Infect       Date:  2010-10-07       Impact factor: 6.072

2.  Outcome of a hemispherical porous-coated acetabular component with a proximally hydroxyapatite-coated anatomical femoral component: a 12- to 15-year follow-up study.

Authors:  E García-Rey; E García-Cimbrelo; J Cordero-Ampuero
Journal:  J Bone Joint Surg Br       Date:  2009-03

Review 3.  Current progress in inorganic artificial biomaterials.

Authors:  Zhixia Li; Masakazu Kawashita
Journal:  J Artif Organs       Date:  2011-07-07       Impact factor: 1.731

Review 4.  Uncemented custom computer-assisted design and manufacture of hydroxyapatite-coated femoral components: survival at 10 to 17 years.

Authors:  S K Muirhead-Allwood; N Sandiford; J A Skinner; J Hua; C Kabir; P S Walker
Journal:  J Bone Joint Surg Br       Date:  2010-08

Review 5.  Novel bioactive materials with different mechanical properties.

Authors:  Tadashi Kokubo; Hyun-Min Kim; Masakazu Kawashita
Journal:  Biomaterials       Date:  2003-06       Impact factor: 12.479

6.  Second-generation proximally coated titanium femoral component: minimum 7-year results.

Authors:  Paul F Lachiewicz; Elizabeth S Soileau; Paul Bryant
Journal:  Clin Orthop Relat Res       Date:  2007-12       Impact factor: 4.176

7.  Comparison of porous-coated titanium femoral stems with and without hydroxyapatite coating.

Authors:  Young-Hoo Kim; Jun-Shik Kim; Seung-Hwan Oh; Ju-Moon Kim
Journal:  J Bone Joint Surg Am       Date:  2003-09       Impact factor: 5.284

Review 8.  Hydroxyapatite coating on the femoral stem in primary total hip arthroplasty.

Authors:  Benjamin E Bierbaum; Erik N Zeegen; Michael R Dayton
Journal:  Orthopedics       Date:  2003-09       Impact factor: 1.390

9.  Seven-year results of a tapered, titanium, hydroxyapatite-coated cementless femoral stem in primary total hip arthroplasty.

Authors:  Jin-Ho Cho; Jonathan P Garino; Suk-Kyu Choo; Kye-Young Han; Jung-Hoon Kim; Hyoung-Keun Oh
Journal:  Clin Orthop Surg       Date:  2010-11-05

10.  Effects of hydroxyapatite coating on survival of an uncemented femoral stem. A Swedish Hip Arthroplasty Register study on 4,772 hips.

Authors:  Stergios Lazarinis; Johan Kärrholm; Nils P Hailer
Journal:  Acta Orthop       Date:  2011-07-13       Impact factor: 3.717