Literature DB >> 991504

Radiological demarcation of cemented sockets in total hip replacement.

J G DeLee, J Charnley.   

Abstract

The frequency of radiological demarcation of the cement-bone junction in the acetabulum after total hip replacement has been examined in 141 Charnley low-friction arthroplasties followed for an average of 10.1 years. Sixty-nine per cent showed demarcation of various degrees and 9.2 per cent of the series showed evidence of progressive migration of the socket. The vast majority of cases with demarcation were symptomless. In most cases where demarcation was accompanied by migration the operation notes suggested a technical explanation and in three cases low-grade sepsis was responsible. The fact that nearly 30 per cent of cases showed no demarcation even after 10 years supports the idea that there is no fundamental defect in the principle of employing cement in the acetabulum. Better surgical technique may increase the number of cases showing no demarcation.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 991504

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  562 in total

1.  How long should patients be followed-up after total hip replacement? Current practice in the UK.

Authors:  M J Bankes; R Coull; B D Ferris
Journal:  Ann R Coll Surg Engl       Date:  1999-09       Impact factor: 1.891

2.  Highly crosslinked polyethylene does not reduce aseptic loosening in cemented THA 10-year findings of a randomized study.

Authors:  Per-Erik Johanson; Georgios Digas; Peter Herberts; Jonas Thanner; Johan Kärrholm
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

3.  Low incidence of groin pain and early failure with large metal articulation total hip arthroplasty.

Authors:  John B Meding; Lindsey K Meding; E Michael Keating; Michael E Berend
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

4.  High revision rate at 5 years after hip resurfacing with the Durom implant.

Authors:  Florian D Naal; Ronny Pilz; Urs Munzinger; Otmar Hersche; Michael Leunig
Journal:  Clin Orthop Relat Res       Date:  2011-01-29       Impact factor: 4.176

5.  Effect of cup geometry and the presence of cement on acetabular component fixation.

Authors:  J Timperley; G Bannister; G Gie; P Ring; R Ling
Journal:  Arch Orthop Trauma Surg       Date:  1992       Impact factor: 3.067

6.  Comparison of wear and osteolysis in hip replacement using two different coatings of the femoral stem.

Authors:  Joaquin Sanchez-Sotelo; David G Lewallen; William Scott Harmsen; Jeffrey Harrington; Miguel E Cabanela
Journal:  Int Orthop       Date:  2004-04-29       Impact factor: 3.075

7.  Early aseptic loosening of cemented total hip arthroplasty: the influence of non-steroidal anti-inflammatory drugs and smoking.

Authors:  M H A Malik; J Gray; P R Kay
Journal:  Int Orthop       Date:  2004-03-27       Impact factor: 3.075

8.  A scoring system to determine radiological loosening in cemented total hip arthroplasty.

Authors:  D M Dall; I D Learmonth; M Solomon
Journal:  Int Orthop       Date:  1992       Impact factor: 3.075

9.  Ten year results of the collum femoris preserving total hip replacement: a prospective cohort study of seventy five patients.

Authors:  Jonathan Hutt; Ziad Harb; Ian Gill; Fadhil Kashif; John Miller; Matthew Dodd
Journal:  Int Orthop       Date:  2013-12-10       Impact factor: 3.075

10.  Genetic susceptibility to hip arthroplasty failure--association with the RANK/OPG pathway.

Authors:  M H A Malik; A Bayat; F Jury; W E R Ollier; P R Kay
Journal:  Int Orthop       Date:  2006-04-01       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.