Thirty years of experience with alumina-on-alumina bearings in total hip arthroplasty.

Didier Hannouche1, Amine Zaoui, Frédéric Zadegan, Laurent Sedel, Rémy Nizard.   

Abstract

Alumina-on-alumina bearings in total hip arthroplasty have been developed in an attempt to minimise debris and the occurrence of osteolytic lesions. The outstanding tribological properties of this bearing system are explained by low surface roughness, high hardness for major scratch resistance, and high wettability. Since the 1970s, technological improvements in the manufacturing process of alumina components together with a better understanding of Morse taper technology have provided a surgical grade material with high density, high purity and small grains. Published studies on the outcome of total hip arthroplasty performed with this new generation of implants showed high survivorship especially in young and active patients, with survival rates free of revision of 90.8% to 97.4% at ten years. However, concern remains over ceramic liner fracture and squeaking, which has been noted recently with increasing prevalence. This review will discuss the current knowledge on the use of alumina-on-alumina bearings.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21191579      PMCID: PMC3032121          DOI: 10.1007/s00264-010-1187-1

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  51 in total

1.  Modes of failure of a threaded acetabular cup : a radiographic study with EBRA of 42 revised cups.

Authors:  Thomas Ilchmann; Severin Neher; Franz Maurer; Kuno Weise
Journal:  Int Orthop       Date:  2006-06-08       Impact factor: 3.075

2.  The role of stripe wear in causing acoustic emissions from alumina ceramic-on-ceramic bearings.

Authors:  Scott Taylor; Michael T Manley; Kate Sutton
Journal:  J Arthroplasty       Date:  2007-10       Impact factor: 4.757

Review 3.  The squeaking hip: a cause for concern-agrees.

Authors:  Amar S Ranawat; Chitranjan S Ranawat
Journal:  Orthopedics       Date:  2007-09       Impact factor: 1.390

4.  High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings.

Authors:  J C Keurentjes; R M Kuipers; D J Wever; B W Schreurs
Journal:  Clin Orthop Relat Res       Date:  2008-02-26       Impact factor: 4.176

5.  Ceramic liner fracture after cementless alumina-on-alumina total hip arthroplasty.

Authors:  Yong-Chan Ha; Shin-Yoon Kim; Hee Joong Kim; Jeong Joon Yoo; Kyung-Hoi Koo
Journal:  Clin Orthop Relat Res       Date:  2007-05       Impact factor: 4.176

6.  Failure of a stainless-steel femoral head of a revision total hip arthroplasty performed after a fracture of a ceramic femoral head. A case report.

Authors:  J Allain; D Goutallier; M C Voisin; S Lemouel
Journal:  J Bone Joint Surg Am       Date:  1998-09       Impact factor: 5.284

Review 7.  Ceramics in total hip replacement.

Authors:  Didier Hannouche; Moussa Hamadouche; Rémy Nizard; Pascal Bizot; Alain Meunier; Laurent Sedel
Journal:  Clin Orthop Relat Res       Date:  2005-01       Impact factor: 4.176

8.  Cementless bulk alumina socket: preliminary results at 6 years.

Authors:  M Hamadouche; R S Nizard; A Meunier; P Bizot; L Sedel
Journal:  J Arthroplasty       Date:  1999-09       Impact factor: 4.757

9.  Total hip arthroplasty performed without cement in patients with femoral head osteonecrosis who are less than 50 years old.

Authors:  M A Fye; M H Huo; L E Zatorski; K J Keggi
Journal:  J Arthroplasty       Date:  1998-12       Impact factor: 4.757

10.  Characterisation of wear particles produced by metal on metal and ceramic on metal hip prostheses under standard and microseparation simulation.

Authors:  Christopher Brown; Sophie Williams; Joanne L Tipper; John Fisher; Eileen Ingham
Journal:  J Mater Sci Mater Med       Date:  2006-12-14       Impact factor: 4.727

View more
  33 in total

1.  Fractures of a sandwich ceramic liner at ten year follow-up.

Authors:  Anthony Viste; Julien Chouteau; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2011-10-20       Impact factor: 3.075

2.  Experience with sandwich liner and its high rate of failure.

Authors:  John Junghun Shin; Ji-Soo Shin; Jae-Hyun Kim; Sung Kwan Hwang
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-07-16

3.  Total Hip Arthroplasty, state of the art for the 21st century.

Authors:  Jean-Pierre Courpied; Jacques Henri Caton
Journal:  Int Orthop       Date:  2011-01-18       Impact factor: 3.075

4.  CORR Insights(®): do alumina matrix composite bearings decrease hip noises and bearing fractures at a minimum of 5 years after THA?

Authors:  Laurent Sedel
Journal:  Clin Orthop Relat Res       Date:  2015-07-23       Impact factor: 4.176

5.  Clinical faceoff: Ceramic-on-ceramic THA: do the advantages outweigh the limitations?

Authors:  Laurent Sedel; William L Walter; Rocco P Pitto
Journal:  Clin Orthop Relat Res       Date:  2014-05-13       Impact factor: 4.176

Review 6.  Systematic review of potential health risks posed by pharmaceutical, occupational and consumer exposures to metallic and nanoscale aluminum, aluminum oxides, aluminum hydroxide and its soluble salts.

Authors:  Calvin C Willhite; Nataliya A Karyakina; Robert A Yokel; Nagarajkumar Yenugadhati; Thomas M Wisniewski; Ian M F Arnold; Franco Momoli; Daniel Krewski
Journal:  Crit Rev Toxicol       Date:  2014-10       Impact factor: 5.635

7.  Ceramic bearings with bilayer coating in cementless total hip arthroplasty. A safe solution. A retrospective study of one hundred and twenty six cases with more than ten years' follow-up.

Authors:  André Ferreira; Thierry Aslanian; Thibaud Dalin; Jean Picaud
Journal:  Int Orthop       Date:  2016-08-20       Impact factor: 3.075

8.  Clinical Faceoff: Instability After THA: The Potential Role of the Bearing Surface.

Authors:  Javad Parvizi; Laurent Sedel; Michael J Dunbar
Journal:  Clin Orthop Relat Res       Date:  2018-04       Impact factor: 4.176

9.  High failure rate of a new pressfit cup in mid-term follow-up.

Authors:  Steffen Brodt; Georg Matziolis; Christoph Windisch; Andreas Gosse; Matthias Spalteholz; Ralf Herbert Gahr
Journal:  Int Orthop       Date:  2015-07-08       Impact factor: 3.075

10.  Charnley-Kerboull total hip arthroplasty combining zirconia on polyethylene. A minimum eight-year follow-up prospective study.

Authors:  Jean Langlois; Samer El Hage; Faouzi Madi; Jean-Pierre Courpied; Marcel Kerboull; Moussa Hamadouche
Journal:  Int Orthop       Date:  2013-01-31       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.