Literature DB >> 12807319

Excellent results of HA coating on a grit-blasted stem: 245 patients followed for 8-12 years.

Olav Reikerås1, Ragnhild B Gunderson.   

Abstract

We report the outcome of a grit-blasted titanium stem designed for press-fit insertion and entirely plasma sprayed with HA. During the years 1988-1993, we performed 323 primary total hip replacements in 276 patients (189 women) with a HA-coated prosthesis. Their mean age was 48 (15-79) years. During the follow-up, 12 patients died. 19 other patients did not attend the follow-up examination, but had no major symptoms according to telephone interviews and written replies. Thus, 245 patients (291 hips) were followed for a mean of 10 (8-12) years with radiographic and clinical examinations. Only 1 stem was revised due to mechanical failure. None were revised because of infection. Osteolysis was significantly associated with wear, and wear was significantly associated with the size of the femoral head. We found a small amount of proximal bone loss (37/291) and a low incidence of distal hypertrophy of the bone (23/291). These observations indicate an essentially physiological weight distribution from the stem to the femoral bone. The changes in the bone confirmed that the femoral component was well fixed in asymptomatic patients. To conclude, we found excellent 8-12-year results with a fully HA-coated femoral prosthesis designed for press-fit insertion.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12807319     DOI: 10.1080/00016470310013851

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  21 in total

1.  Excellent results with cementless total hip arthroplasty and alumina-on-alumina pairing: minimum ten-year follow-up.

Authors:  Alexander M Kress; Rainer Schmidt; Ulrich Holzwarth; Raimund Forst; Lutz A Mueller
Journal:  Int Orthop       Date:  2010-11-16       Impact factor: 3.075

2.  Enhanced cell integration to titanium alloy by surface treatment with microarc oxidation: a pilot study.

Authors:  Young Wook Lim; Soon Yong Kwon; Doo Hoon Sun; Hyoun Ee Kim; Yong Sik Kim
Journal:  Clin Orthop Relat Res       Date:  2009-05-12       Impact factor: 4.176

3.  Cemented versus uncemented hemiarthroplasty for displaced femoral neck fractures.

Authors:  Wender Figved; Vidar Opland; Frede Frihagen; Tore Jervidalo; Jan Erik Madsen; Lars Nordsletten
Journal:  Clin Orthop Relat Res       Date:  2009-01-07       Impact factor: 4.176

4.  Cemented versus uncemented hemiarthroplasty for displaced femoral neck fractures: 5-year followup of a randomized trial.

Authors:  Ellen Langslet; Frede Frihagen; Vidar Opland; Jan Erik Madsen; Lars Nordsletten; Wender Figved
Journal:  Clin Orthop Relat Res       Date:  2013-10-01       Impact factor: 4.176

5.  Cementless total hip arthroplasty in patients with rheumatoid arthritis using a tapered designed titanium hip stem minimum: 10-year results.

Authors:  Hans D Carl; Jan Ploetzner; Bernd Swoboda; Gerd Weseloh; Lutz Arne Mueller
Journal:  Rheumatol Int       Date:  2009-12-18       Impact factor: 2.631

6.  The effect of surface treatments on the adhesion of electrochemically deposited hydroxyapatite coating to titanium and on its interaction with cells and bacteria.

Authors:  Noam Eliaz; Oshrit Ritman-Hertz; Daniel Aronov; Evgeny Weinberg; Yotam Shenhar; Gil Rosenman; Miron Weinreb; Eliora Ron
Journal:  J Mater Sci Mater Med       Date:  2011-05-25       Impact factor: 3.896

7.  Regenerated silk materials for functionalized silk orthopedic devices by mimicking natural processing.

Authors:  Chunmei Li; Blake Hotz; Shengjie Ling; Jin Guo; Dylan S Haas; Benedetto Marelli; Fiorenzo Omenetto; Samuel J Lin; David L Kaplan
Journal:  Biomaterials       Date:  2016-09-20       Impact factor: 12.479

8.  Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA study.

Authors:  David Campbell; Graham Mercer; Kjell G Nilsson; Vanessa Wells; John R Field; Stuart A Callary
Journal:  Int Orthop       Date:  2009-12-13       Impact factor: 3.075

9.  An in vivo evaluation of bone response to three implant surfaces using a rabbit intramedullary rod model.

Authors:  Juan C Hermida; Arnie Bergula; Fred Dimaano; Monica Hawkins; Clifford W Colwell; Darryl D D'Lima
Journal:  J Orthop Surg Res       Date:  2010-08-16       Impact factor: 2.359

10.  Hip arthroplasty in patients younger than 30 years: excellent ten to 16-year follow-up results with a HA-coated stem.

Authors:  H Wangen; P Lereim; I Holm; R Gunderson; O Reikerås
Journal:  Int Orthop       Date:  2007-02-15       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.