Literature DB >> 10708076

Clinical and radiographic evaluation of the Harris-Galante cup: incidence of wear and osteolysis at 7 to 9 years follow-up.

M O Soto1, J A Rodriguez, C S Ranawat.   

Abstract

A retrospective evaluation of the clinical and radiographic results of the Harris-Galante acetabular cups was performed in 112 patients with 127 total hip arthroplasties. Patients with 14 hips had died, and patients with 20 hips were lost to follow-up. A total of 82 patients with 93 hips was available for follow-up. There were 67 men and 45 women. The mean follow-up was 87 months (range, 48-113 months). There were a total of 9 revisions: 2 for recurrent dislocations, 1 for a loose cup, and 6 for wear and osteolysis. Radiographic evaluation demonstrated that 22 (24%) hips had periacetabular osteolysis, and 16 of these 22 (73%) were associated with the screws. Twenty-two hips (23%) demonstrated osteolytic lesions around the femoral stem. Mean femoral head displacement was of 1.00 mm (range, 0.40-4.5 mm) with a rate of 0.16 mm/yr (range, 0.05-0.44 mm/yr). The Harris-Galante socket has maintained a low implant failure rate at intermediate term, even in these young patients. As follow-up increases, wear of the polyethylene and periprosthetic osteolysis may become growing concerns.

Entities:  

Mesh:

Year:  2000        PMID: 10708076     DOI: 10.1016/s0883-5403(00)90022-6

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  7 in total

1.  The incidence of acetabular osteolysis in young patients with conventional versus highly crosslinked polyethylene.

Authors:  Nathan A Mall; Ryan M Nunley; Jin Jun Zhu; William J Maloney; Robert L Barrack; John C Clohisy
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

2.  Effects of screw eccentricity on the initial stability of the acetabular cup.

Authors:  Jui-Ting Hsu; Chih-Han Chang; Kai-Nan An; Mark E Zobitz; Rapin Phimolsarnti; Ronald R Hugate; Kuo-An Lai
Journal:  Int Orthop       Date:  2006-09-01       Impact factor: 3.075

3.  Correlation of computed tomography with histology in the assessment of periprosthetic defect healing.

Authors:  Stephen D Cook; Laura P Patron; Samantha L Salkeld; Kirk E Smith; Bruce Whiting; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2009-12       Impact factor: 4.176

4.  Behavior of Hylamer polyethylene in hip arthroplasty: comparison of two gamma sterilization techniques.

Authors:  S Stea; B Antonietti; F Baruffaldi; M Visentin; B Bordini; A Sudanese; A Toni
Journal:  Int Orthop       Date:  2005-10-11       Impact factor: 3.075

5.  Second-generation modular acetabular components provide fixation at 10 to 16 years.

Authors:  Paul F Lachiewicz; Elizabeth S Soileau
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

6.  A stature-specific concept for uncemented, primary total hip arthroplasty.

Authors:  Georg W Omlor; Hannah Ullrich; Knut Krahmer; Alexander Jung; Günther Aldinger; Peter Aldinger
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

7.  Comparison of total hip arthroplasty in osteoarthritis of mechanical and rheumatologic causes.

Authors:  Leandro Ejnisman; Nathalia Zalc Leonhardt; Laura Fillipini Lorimier Fernandes; Marcos de Camargo Leonhardt; José Ricardo Negreiros Vicente; Alberto Tesconi Croci
Journal:  Acta Ortop Bras       Date:  2014       Impact factor: 0.513

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.