Literature DB >> 2324138

Effect of femoral head size on wear of the polyethylene acetabular component.

J Livermore1, D Ilstrup, B Morrey.   

Abstract

A technique was developed to determine the wear of the acetabular component of a total hip replacement by examination of standardized initial and follow-up radiographs. Three hundred and eighty-five hips were followed for at least 9.5 years after replacement. The least amount and rate of linear wear were associated with use of a femoral head that had a diameter of twenty-eight millimeters (p less than 0.001). The greatest amount and mean rate of linear wear occurred with twenty-two-millimeter components, but these differences were not statistically significant. The greatest volumetric wear and mean rate rate of volumetric wear were seen with thirty-two-millimeter components (p less than 0.001). A wider radiolucent line in acetabular Zone 1 was associated with use of the thirty-two-millimeter head. The amounts of resorption of the proximal part of the femoral neck and of lysis of the proximal part of the femur both correlated positively with the extent of linear and volumetric wear; this suggests an association between the amount of debris from wear and these changes in the femoral neck and proximal part of the femur.

Entities:  

Mesh:

Year:  1990        PMID: 2324138

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  106 in total

1.  Increased volumetric wear of polyethylene liners with more than 3 years of shelf-life time.

Authors:  T J S Puolakka; J T Keränen; K A Juhola; K J J Pajamäki; P J Halonen; J K Nevalainen; V Saikko; M U K Lehto; M Järvinen
Journal:  Int Orthop       Date:  2003-04-01       Impact factor: 3.075

2.  Highly crosslinked polyethylene does not reduce aseptic loosening in cemented THA 10-year findings of a randomized study.

Authors:  Per-Erik Johanson; Georgios Digas; Peter Herberts; Jonas Thanner; Johan Kärrholm
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

3.  Implant wear and osteolysis with a hydroxylapatite-coated screw cup.

Authors:  E H van Haaren; I C Heyligers
Journal:  Int Orthop       Date:  2003-07-04       Impact factor: 3.075

4.  Comparison of wear and osteolysis in hip replacement using two different coatings of the femoral stem.

Authors:  Joaquin Sanchez-Sotelo; David G Lewallen; William Scott Harmsen; Jeffrey Harrington; Miguel E Cabanela
Journal:  Int Orthop       Date:  2004-04-29       Impact factor: 3.075

5.  Quantitative analysis of polyethylene wear debris, wear rate and head damage in retrieved Charnley hip prostheses.

Authors:  J L Tipper; E Ingham; J L Hailey; A A Besong; J Fisher; B M Wroblewski; M H Stone
Journal:  J Mater Sci Mater Med       Date:  2000-02       Impact factor: 3.896

6.  The influence of stress conditions on the wear of UHMWPE for total joint replacements.

Authors:  P S Barbour; D C Barton; J Fisher
Journal:  J Mater Sci Mater Med       Date:  1997-10       Impact factor: 3.896

7.  Wear analysis of chamfered elongated acetabular cup liners.

Authors:  Hsiao-Che Lin; Tzuo-Liang Luo; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2011-12-22       Impact factor: 2.602

8.  Continued improved wear with an annealed highly cross-linked polyethylene.

Authors:  William N Capello; James A D'Antonio; Rama Ramakrishnan; Marybeth Naughton
Journal:  Clin Orthop Relat Res       Date:  2010-09-16       Impact factor: 4.176

9.  The incidence of acetabular osteolysis in young patients with conventional versus highly crosslinked polyethylene.

Authors:  Nathan A Mall; Ryan M Nunley; Jin Jun Zhu; William J Maloney; Robert L Barrack; John C Clohisy
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

10.  Polyethylene and highly cross-linked polyethylene for cemented total hip arthroplasty: A comparison of over ten-year clinical and radiographic results.

Authors:  Tomotoshi Kawata; Koji Goto; Kazutaka So; Yutaka Kuroda; Shuichi Matsuda
Journal:  J Orthop       Date:  2017-08-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.