Literature DB >> 25903943

Wear and Osteolysis of Highly Crosslinked Polyethylene at 10 to 14 Years: The Effect of Femoral Head Size.

Paul F Lachiewicz1, Elizabeth S Soileau2, John M Martell3.   

Abstract

BACKGROUND: Highly crosslinked polyethylene (XLPE) was introduced to decrease periprosthetic osteolysis related to polyethylene wear, a major reason for revision of total hip arthroplasty. However, there are few reports of wear and osteolysis at 10 years postoperatively. QUESTIONS/PURPOSES: (1) What are the linear and volumetric wear rates of XLPE at 10 to 14 years? (2) What is the relationship among linear wear, volumetric wear, and femoral head size? (3) What proportion of hips developed osteolysis and was there a relationship between osteolysis and femoral head size or polyethylene wear?
METHODS: We evaluated a previously reported cohort of 84 hips (72 patients) with one design of an uncemented acetabular component and one electron beam 10-kGy irradiated and remelted XLPE at a mean followup of 11 years (range, 10-14 years). The choice of femoral head size was based on several factors, including the outer diameter size of the acetabular component implanted, the perceived risk of dislocation (including the history of alcohol abuse and patient age), and liner availability from the manufacturer. The femoral head sizes used were 26 mm in 10 hips (12%), 28 mm in 31 hips (37%), 32 mm in 31 hips (37%), 36 mm in eight hips (10%), and 40 mm in four hips (5%). Measurements of linear and volumetric wear were performed in one experienced laboratory by the Martell method and analyzed using the first-to-last method. Standard radiographs, with additional Judet views, were used to detect periprosthetic osteolysis. Statistical analysis of wear and osteolysis compared with head size was performed.
RESULTS: For the entire cohort, the median linear wear rate as 0.024 mm/year (95% confidence interval [CI], 0.016-0.030) and the median volumetric wear rate was 12.19 mm(3)/year (95% CI, 6.6-15.7). With the numbers available, we found no association between femoral head size and linear wear rate. However, larger femoral heads were associated with more volumetric wear; 36/40-mm femoral heads had higher volumetric wear (median 26.1; 95% CI, 11.3-47.1) than did 26-mm heads (median 3.1; 95% CI, 0.7-12.3), 28-mm heads (median 12.3; 95% CI, 3.0-19.3), and 32-mm heads (median 12.9; 95% CI, 6.6-16.8; p = 0.02). Small osteolytic lesions were noted in 12 hips (14%), but with the numbers available, there was no association with head size or volumetric wear rates.
CONCLUSIONS: This uncemented acetabular component and this particular XLPE had low rates of linear and volumetric wear. Small osteolytic lesions were noted at 10 to 14 years but were not related to femoral head size or linear or volumetric wear rates. We recommend additional longer-term clinical followup studies and perhaps alternative imaging studies of patients with XLPE and osteolysis. LEVEL OF EVIDENCE: Level III, therapeutic study.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 25903943      PMCID: PMC4709306          DOI: 10.1007/s11999-015-4319-5

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  26 in total

1.  The influence of patient-related factors and the position of the acetabular component on the rate of dislocation after total hip replacement.

Authors:  S A Paterno; P F Lachiewicz; S S Kelley
Journal:  J Bone Joint Surg Am       Date:  1997-08       Impact factor: 5.284

2.  Stability of total hip arthroplasty in patients 75 years or older.

Authors:  Paul F Lachiewicz; Elizabeth S Soileau
Journal:  Clin Orthop Relat Res       Date:  2002-12       Impact factor: 4.176

3.  Relationship of femoral head and acetabular size to the prevalence of dislocation.

Authors:  S S Kelley; P F Lachiewicz; J M Hickman; S M Paterno
Journal:  Clin Orthop Relat Res       Date:  1998-10       Impact factor: 4.176

4.  Radiological demarcation of cemented sockets in total hip replacement.

Authors:  J G DeLee; J Charnley
Journal:  Clin Orthop Relat Res       Date:  1976 Nov-Dec       Impact factor: 4.176

5.  Determination of polyethylene wear in total hip replacements with use of digital radiographs.

Authors:  J M Martell; S Berdia
Journal:  J Bone Joint Surg Am       Date:  1997-11       Impact factor: 5.284

6.  Total hip arthroplasty using highly cross-linked polyethylene in patients younger than 50 years with minimum 10-year follow-up.

Authors:  Nikola Babovic; Robert T Trousdale
Journal:  J Arthroplasty       Date:  2013-03-15       Impact factor: 4.757

7.  Evaluation of cementless acetabular component migration. An experimental study.

Authors:  P Massin; L Schmidt; C A Engh
Journal:  J Arthroplasty       Date:  1989-09       Impact factor: 4.757

8.  Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation.

Authors:  W H Harris
Journal:  J Bone Joint Surg Am       Date:  1969-06       Impact factor: 5.284

9.  Clinical performance of a highly cross-linked polyethylene at two years in total hip arthroplasty: a randomized prospective trial.

Authors:  John M Martell; James J Verner; Stephen J Incavo
Journal:  J Arthroplasty       Date:  2003-10       Impact factor: 4.757

10.  Comparison of two and three-dimensional computerized polyethylene wear analysis after total hip arthroplasty.

Authors:  John M Martell; Eric Berkson; Richard Berger; Joshua Jacobs
Journal:  J Bone Joint Surg Am       Date:  2003-06       Impact factor: 5.284

View more
  20 in total

1.  Wear performance of cobalt chromium, ceramic, and oxidized zirconium on highly crosslinked polyethylene at mid-term follow-up.

Authors:  Matthew G Teeter; Colin J MacLean; Lyndsay E Somerville; James L Howard; Richard W McCalden; Brent A Lanting; Edward M Vasarhelyi
Journal:  J Orthop       Date:  2018-05-07

2.  CORR Insights®: Prediction of Polyethylene Wear Rates from Gait Biomechanics and Implant Positioning in Total Hip Replacement.

Authors:  Stephen Li
Journal:  Clin Orthop Relat Res       Date:  2017-04-25       Impact factor: 4.176

3.  No Increase in Survival for 36-mm versus 32-mm Femoral Heads in Metal-on-polyethylene THA: A Registry Study.

Authors:  Georgios Tsikandylakis; Johan Kärrholm; Nils P Hailer; Antti Eskelinen; Keijo T Mäkelä; Geir Hallan; Ove Nord Furnes; Alma B Pedersen; Søren Overgaard; Maziar Mohaddes
Journal:  Clin Orthop Relat Res       Date:  2018-12       Impact factor: 4.176

4.  Otto Aufranc Award: Crosslinking Reduces THA Wear, Osteolysis, and Revision Rates at 15-year Followup Compared With Noncrosslinked Polyethylene.

Authors:  Robert H Hopper; Henry Ho; Supatra Sritulanondha; Ann C Williams; Charles A Engh
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

5.  Design Considerations for the Next Generation Hip Resurfacing Implant: Commentary.

Authors:  Edwin P Su
Journal:  HSS J       Date:  2016-12-19

6.  Highly Crosslinked Polyethylene Liners Have Negligible Wear at 10 Years: A Radiostereometric Analysis Study.

Authors:  David G Campbell; Stuart A Callary
Journal:  Clin Orthop Relat Res       Date:  2022-03-01       Impact factor: 4.755

7.  Low failure rate at short term for 40 mm heads and second generation triple annealed HCLPE liners in hybrid hip replacements.

Authors:  Rajkumar Thangaraj; Jan Kuiper; Ralph D Perkins
Journal:  J Clin Orthop Trauma       Date:  2018-01-03

8.  Simultaneous Characterization of Implant Wear and Tribocorrosion Debris within Its Corresponding Tissue Response Using Infrared Chemical Imaging.

Authors:  Songyun Liu; Deborah J Hall; Craig J Della Valle; Michael J Walsh; Joshua J Jacobs; Robin Pourzal
Journal:  Biotribology (Oxf)       Date:  2021-02-19

9.  Head size in primary total hip arthroplasty.

Authors:  Georgios Tsikandylakis; Maziar Mohaddes; Peter Cnudde; Antti Eskelinen; Johan Kärrholm; Ola Rolfson
Journal:  EFORT Open Rev       Date:  2018-05-21

10.  Long-term performance of oxidized zirconium on conventional and highly cross-linked polyethylene in total hip arthroplasty.

Authors:  Alberto V Carli; Anay R Patel; Michael B Cross; David J Mayman; Kaitlin M Carroll; Paul M Pellicci; Seth A Jerabek
Journal:  SICOT J       Date:  2020-05-07
View more