Literature DB >> 21267569

Polyethylene and metal wear particles: characteristics and biological effects.

Isabelle Catelas1, Markus A Wimmer, Sandra Utzschneider.   

Abstract

This paper first presents a brief overview about the mechanism of wear particle formation as well as wear particle characteristics in metal-on-polyethylene and metal-on-metal artificial hip joints. The biological effects of such particles are then described, focusing on the inflammatory response induced by each type of particles as well as on how metal wear products may be the source of a T lymphocyte-mediated specific immune response, early adverse tissue responses, and genotoxicity. Finally, some of the current in vivo models used for the analysis of tissue response to various wear particles are presented.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21267569     DOI: 10.1007/s00281-011-0242-3

Source DB:  PubMed          Journal:  Semin Immunopathol        ISSN: 1863-2297            Impact factor:   9.623


  142 in total

1.  Implications of orthopedic fretting corrosion particles on skeletal muscle microcirculation.

Authors:  C N Kraft; B Burian; O Diedrich; M A Wimmer
Journal:  J Mater Sci Mater Med       Date:  2001 Oct-Dec       Impact factor: 3.896

2.  Particle analysis for the determination of UHMWPE wear.

Authors:  M Scott; M Morrison; S R Mishra; S Jani
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2005-05       Impact factor: 3.368

3.  Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space.

Authors:  T P Schmalzried; M Jasty; W H Harris
Journal:  J Bone Joint Surg Am       Date:  1992-07       Impact factor: 5.284

4.  TNF-alpha secretion and macrophage mortality induced by cobalt and chromium ions in vitro-qualitative analysis of apoptosis.

Authors:  Isabelle Catelas; Alain Petit; David J Zukor; John Antoniou; Olga L Huk
Journal:  Biomaterials       Date:  2003-02       Impact factor: 12.479

5.  The effects of particulate bone cements at the bone-implant interface.

Authors:  J A Wimhurst; R A Brooks; N Rushton
Journal:  J Bone Joint Surg Br       Date:  2001-05

6.  2008 John Charnley award: metal ion levels after metal-on-metal total hip arthroplasty: a randomized trial.

Authors:  C Anderson Engh; Steven J MacDonald; Supatra Sritulanondha; Abigail Thompson; Douglas Naudie; Charles A Engh
Journal:  Clin Orthop Relat Res       Date:  2008-10-15       Impact factor: 4.176

7.  Tissue ingrowth and differentiation in the bone-harvest chamber in the presence of cobalt-chromium-alloy and high-density-polyethylene particles.

Authors:  S Goodman; P Aspenberg; Y Song; G Knoblich; P Huie; D Regula; L Lidgren
Journal:  J Bone Joint Surg Am       Date:  1995-07       Impact factor: 5.284

8.  A rat model of resorption of bone at the cement-bone interface in the presence of polyethylene wear particles.

Authors:  D W Howie; B Vernon-Roberts; R Oakeshott; B Manthey
Journal:  J Bone Joint Surg Am       Date:  1988-02       Impact factor: 5.284

9.  In vivo murine model of continuous intramedullary infusion of particles--a preliminary study.

Authors:  Ting Ma; Steven G Ortiz; Zhinong Huang; Peigen Ren; R Lane Smith; Stuart B Goodman
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2009-01       Impact factor: 3.368

10.  Investigation of the binding of Cr(III) complexes to bovine and human serum proteins: a proteomic approach.

Authors:  Cathy Tkaczyk; Olga L Huk; Fackson Mwale; John Antoniou; David J Zukor; Alain Petit; Maryam Tabrizian
Journal:  J Biomed Mater Res A       Date:  2010-07       Impact factor: 4.396

View more
  19 in total

1.  Highly crosslinked polyethylene does not reduce aseptic loosening in cemented THA 10-year findings of a randomized study.

Authors:  Per-Erik Johanson; Georgios Digas; Peter Herberts; Jonas Thanner; Johan Kärrholm
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

2.  Implanted devices: biocompatibility, infection and tissue engineering.

Authors:  Werner Zimmerli
Journal:  Semin Immunopathol       Date:  2011-05-21       Impact factor: 9.623

3.  Biological activity and migration of wear particles in the knee joint: an in vivo comparison of six different polyethylene materials.

Authors:  S Utzschneider; V Lorber; M Dedic; A C Paulus; C Schröder; O Gottschalk; M Schmitt-Sody; V Jansson
Journal:  J Mater Sci Mater Med       Date:  2014-02-22       Impact factor: 3.896

4.  [Principles of tribological analysis of endoprostheses].

Authors:  J P Kretzer; C Zietz; C Schröder; J Reinders; L Middelborg; A Paulus; R Sonntag; R Bader; S Utzschneider
Journal:  Orthopade       Date:  2012-10       Impact factor: 1.087

5.  Wear testing and particle characterisation of sequentially crosslinked polyethylene acetabular liners using different femoral head sizes.

Authors:  Carmen Zietz; Christian Fabry; Lars Middelborg; Gerhard Fulda; Wolfram Mittelmeier; Rainer Bader
Journal:  J Mater Sci Mater Med       Date:  2013-04-25       Impact factor: 3.896

6.  [Supramacroparticulate polyethylene in inflammation of synovial-like interface membranes: Characterization and suggested nomenclature].

Authors:  V Krenn; F Hopf; P Thomas; M Thomsen; S Usbeck; F Boettner; S Müller; D Saberi; T Hügle; M Huber; L Scheuber; J C Hopf; J P Kretzer
Journal:  Orthopade       Date:  2016-03       Impact factor: 1.087

7.  In-situ Generated Tribomaterial in Metal/Metal Contacts: current understanding and future implications for implants.

Authors:  N Espallargas; A Fischer; A Igual Muñoz; S Mischler; M A Wimmer
Journal:  Biotribology (Oxf)       Date:  2017-05-12

8.  The Use of Europiumstearate to Trace Polyethylene Wear Debris in Joint Fluid after Prosthetic Joint Replacement - A Feasibility Study.

Authors:  J Kunze; V Ngai; S Koelling; J J Jacobs; M A Wimmer
Journal:  Trends Appl Spectrosc       Date:  2013

9.  Evaluation of impingement behaviour in lumbar spinal disc arthroplasty.

Authors:  Thomas M Grupp; James J Yue; Rolando Garcia; Christian Kaddick; Bernhard Fritz; Christoph Schilling; Jens Schwiesau; Wilhelm Blömer
Journal:  Eur Spine J       Date:  2014-06-06       Impact factor: 3.134

Review 10.  Non-neoplastic histiocytic and dendritic cell disorders in lymph nodes.

Authors:  Caoimhe Egan; Elaine S Jaffe
Journal:  Semin Diagn Pathol       Date:  2017-11-03       Impact factor: 3.464

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.