Literature DB >> 18766481

Effect of femoral head size on polyethylene wear and synovitis after total hip arthroplasty: a sonographic and radiographic study of 39 patients.

Sarunas Tarasevicius1, Otto Robertsson, Uldis Kesteris, Romas Jonas Kalesinskas, Hans Wingstrand.   

Abstract

BACKGROUND AND
PURPOSE: The role of synovitis and high fluid pressure in the loosening process after total hip arthroplasty has gained increasing attention. We investigated the correlation between head size, polyethylene wear, and capsular distention. PATIENTS AND METHODS: We analyzed 39 unrevised, radiographically stable hips that had been operated with 28 or 32 mm femoral heads 10 years earlier because of osteoarthritis. We evaluated radiographic signs of loosening, linear and volumetric polyethylene wear, body mass index, activity level, and age. Sonographic examination was performed to measure capsular distance i.e. the distance between the prosthetic femoral neck and the anterior capsule.
RESULTS: Linear wear was 0.09 mm/year and 0.18 mm/year in the 28 mm and 32 mm groups, respectively (p < 0.001). The volumetric wear was 51 mm(3)/year and 136 mm(3)/year (p < 0.001) and the capsular distance was 13 mm and 17 mm, respectively (p < 0.001). There was a correlation between linear wear (r = 0.54), volumetric wear (r = 0.62), and capsular distance (p < 0.001).
INTERPRETATION: Wear was greater for the larger femoral head and was correlated to capsular distension.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18766481     DOI: 10.1080/17453670710015472

Source DB:  PubMed          Journal:  Acta Orthop        ISSN: 1745-3674            Impact factor:   3.717


  10 in total

1.  The incidence of acetabular osteolysis in young patients with conventional versus highly crosslinked polyethylene.

Authors:  Nathan A Mall; Ryan M Nunley; Jin Jun Zhu; William J Maloney; Robert L Barrack; John C Clohisy
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

2.  Wear testing and particle characterisation of sequentially crosslinked polyethylene acetabular liners using different femoral head sizes.

Authors:  Carmen Zietz; Christian Fabry; Lars Middelborg; Gerhard Fulda; Wolfram Mittelmeier; Rainer Bader
Journal:  J Mater Sci Mater Med       Date:  2013-04-25       Impact factor: 3.896

Review 3.  Safe clinical use of carbon nanotubes as innovative biomaterials.

Authors:  Naoto Saito; Hisao Haniu; Yuki Usui; Kaoru Aoki; Kazuo Hara; Seiji Takanashi; Masayuki Shimizu; Nobuyo Narita; Masanori Okamoto; Shinsuke Kobayashi; Hiroki Nomura; Hiroyuki Kato; Naoyuki Nishimura; Seiichi Taruta; Morinobu Endo
Journal:  Chem Rev       Date:  2014-04-10       Impact factor: 60.622

4.  Do revision total hip augments provide appropriate modularity?

Authors:  Matthew G Teeter; Douglas D R Naudie; James L Howard; Richard W McCalden; Steven J MacDonald
Journal:  Can J Surg       Date:  2015-02       Impact factor: 2.089

5.  Dual mobility cup reduces dislocation rate after arthroplasty for femoral neck fracture.

Authors:  Sarunas Tarasevicius; Mantas Busevicius; Otto Robertsson; Hans Wingstrand
Journal:  BMC Musculoskelet Disord       Date:  2010-08-06       Impact factor: 2.362

6.  Effect of changing femoral head diameter on bony and prosthetic jumping angles.

Authors:  Takaaki Ohmori; Tamon Kabata; Yoshitomo Kajino; Daisuke Inoue; Tadashi Taga; Takashi Yamamoto; Tomoharu Takagi; Junya Yoshitani; Takuro Ueno; Ken Ueoka; Hiroyuki Tsuchiya
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-10-30

7.  Wear of a sequentially annealed polyethylene acetabular liner.

Authors:  Trevor C Gascoyne; Martin J Petrak; Thomas R Turgeon; Eric R Bohm
Journal:  Acta Orthop       Date:  2014-08-20       Impact factor: 3.717

8.  Future Prospects for Clinical Applications of Nanocarbons Focusing on Carbon Nanotubes.

Authors:  Naoto Saito; Hisao Haniu; Kaoru Aoki; Naoyuki Nishimura; Takeshi Uemura
Journal:  Adv Sci (Weinh)       Date:  2022-06-26       Impact factor: 17.521

9.  Size of cup affects the anterior capsular distance in total hip arthroplasty, as measured with ultrasound.

Authors:  Sarunas Tarasevicius; Valdemaras Loiba; Justinas Stucinskas; Otto Robertsson; Hans Wingstrand
Journal:  BMC Musculoskelet Disord       Date:  2014-01-20       Impact factor: 2.362

10.  Vitamin E-doped total hip arthroplasty liners show similar head penetration to highly cross-linked polyethylene at five years: a multi-arm randomized controlled trial.

Authors:  Kristian Kjærgaard; Ming Ding; Carsten Jensen; Charles Bragdon; Henrik Malchau; Christina M Andreasen; Ole Ovesen; Christian Hofbauer; Søren Overgaard
Journal:  Bone Joint J       Date:  2020-10       Impact factor: 5.082

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.