BACKGROUND AND PURPOSE: The role of synovitis and high fluid pressure in the loosening process after total hip arthroplasty has gained increasing attention. We investigated the correlation between head size, polyethylene wear, and capsular distention. PATIENTS AND METHODS: We analyzed 39 unrevised, radiographically stable hips that had been operated with 28 or 32 mm femoral heads 10 years earlier because of osteoarthritis. We evaluated radiographic signs of loosening, linear and volumetric polyethylene wear, body mass index, activity level, and age. Sonographic examination was performed to measure capsular distance i.e. the distance between the prosthetic femoral neck and the anterior capsule. RESULTS: Linear wear was 0.09 mm/year and 0.18 mm/year in the 28 mm and 32 mm groups, respectively (p < 0.001). The volumetric wear was 51 mm(3)/year and 136 mm(3)/year (p < 0.001) and the capsular distance was 13 mm and 17 mm, respectively (p < 0.001). There was a correlation between linear wear (r = 0.54), volumetric wear (r = 0.62), and capsular distance (p < 0.001). INTERPRETATION: Wear was greater for the larger femoral head and was correlated to capsular distension.
BACKGROUND AND PURPOSE: The role of synovitis and high fluid pressure in the loosening process after total hip arthroplasty has gained increasing attention. We investigated the correlation between head size, polyethylene wear, and capsular distention. PATIENTS AND METHODS: We analyzed 39 unrevised, radiographically stable hips that had been operated with 28 or 32 mm femoral heads 10 years earlier because of osteoarthritis. We evaluated radiographic signs of loosening, linear and volumetric polyethylene wear, body mass index, activity level, and age. Sonographic examination was performed to measure capsular distance i.e. the distance between the prosthetic femoral neck and the anterior capsule. RESULTS: Linear wear was 0.09 mm/year and 0.18 mm/year in the 28 mm and 32 mm groups, respectively (p < 0.001). The volumetric wear was 51 mm(3)/year and 136 mm(3)/year (p < 0.001) and the capsular distance was 13 mm and 17 mm, respectively (p < 0.001). There was a correlation between linear wear (r = 0.54), volumetric wear (r = 0.62), and capsular distance (p < 0.001). INTERPRETATION: Wear was greater for the larger femoral head and was correlated to capsular distension.
Authors: Nathan A Mall; Ryan M Nunley; Jin Jun Zhu; William J Maloney; Robert L Barrack; John C Clohisy Journal: Clin Orthop Relat Res Date: 2011-02 Impact factor: 4.176
Authors: Carmen Zietz; Christian Fabry; Lars Middelborg; Gerhard Fulda; Wolfram Mittelmeier; Rainer Bader Journal: J Mater Sci Mater Med Date: 2013-04-25 Impact factor: 3.896
Authors: Matthew G Teeter; Douglas D R Naudie; James L Howard; Richard W McCalden; Steven J MacDonald Journal: Can J Surg Date: 2015-02 Impact factor: 2.089
Authors: Kristian Kjærgaard; Ming Ding; Carsten Jensen; Charles Bragdon; Henrik Malchau; Christina M Andreasen; Ole Ovesen; Christian Hofbauer; Søren Overgaard Journal: Bone Joint J Date: 2020-10 Impact factor: 5.082